Application of FT-ICR MS Equipped with Quadrupole Detection for Analysis of Crude Oil

被引:64
作者
Cho, Eunji [1 ]
Witt, Matthias [2 ]
Hur, Manhoi [3 ,4 ]
Jung, Maeng-Joon [1 ]
Kim, Sunghwan [1 ,5 ]
机构
[1] Kyungpook Natl Univ, Dept Chem, 80 Daehak Ro, Daegu 41566, South Korea
[2] Bruker Daltonik GmbH, Fahrenheitrasse 4, D-28359 Bremen, Germany
[3] Iowa State Univ, Dept Genet Dev & Cell Biol, Ames, IA 50011 USA
[4] Iowa State Univ, Ctr Metab Biol, Ames, IA 50011 USA
[5] Green Nano Mat Res Ctr, Daegu 41566, South Korea
基金
新加坡国家研究基金会;
关键词
RESONANCE MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; MOLECULAR-LEVEL; PHASE CORRECTION; HYDROTHERMAL LIQUEFACTION; ABSORPTION-MODE; RESOLVING POWER; ORGANIC-MATTER; IONIZATION; RESOLUTION;
D O I
10.1021/acs.analchem.7b02644
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Resolving power is a critical factor determining the quality of ultrahigh-resolving power mass spectra of crude oil. In this study, 7T Fourier-transform ion cyclotron mass spectrometry (FTICR MS), equipped with quadrupole detection, was applied and evaluated for crude oil analysis for the first time. Four spectra were obtained from two oil samples using two ionization methods. Resolving power of 1500000 was observed at m/z 400 with 4 s transient signal. Comparison with literature reports revealed that the achieved resolving power was comparable with or superior to those obtained from instruments using higher magnetic fields but without quadrupole detection. A total of 6000-10000 peaks with an S/N ratio of 3 or higher were observed from the obtained spectra and over 97% of the peaks could be assigned to appropriate chemical formulas with an error within 1 ppm. Double bond equivalents vs carbon number plots generated from the obtained data agreed well with those previously reported without quadrupole detection. Mass accuracy values of the assigned elemental formulas were examined and the average root-mean-square error was calculated to be only 160 ppb. Low unassignment rate of the observed peaks and strong agreement with previously reported results suggests that unwanted harmonics of reduced frequency are not significant for the data obtained with quadrupole detection. Overall, the data presented in this study show that FT-ICR MS equipped with quadrupole detection can be a powerful tool to examine complex mixtures like crude oil. To the best of our knowledge, this is the first paper reporting application of FT-ICR MS equipped with quadrupole detection for the oil analysis.
引用
收藏
页码:12101 / 12107
页数:7
相关论文
共 75 条
  • [1] Application of Atmospheric Pressure Photoionization H/D-exchange Mass Spectrometry for Speciation of Sulfur-containing Compounds
    Acter, Thamina
    Kim, Donghwi
    Ahmed, Arif
    Ha, Ji-Hyoung
    Kim, Sunghwan
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (08) : 1687 - 1695
  • [2] [Anonymous], 2016, FOURIER TRANSFORMS N
  • [3] [Anonymous], IMSC 2016
  • [4] [Anonymous], 2016, STANDARD HDB OIL SPI
  • [5] The N-terminal Domain of Escherichia coli Assimilatory NADPH-Sulfite Reductase Hemoprotein Is an Oligomerization Domain That Mediates Holoenzyme Assembly
    Askenasy, Isabel
    Pennington, Joseph M.
    Tao, Yeqing
    Marshall, Alan G.
    Young, Nicolas L.
    Shang, Weifeng
    Stroupe, M. Elizabeth
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 2015, 290 (31) : 19319 - 19333
  • [6] Identification of about 30 000 Chemical Components in Shale Oils by Electrospray Ionization (ESI) and Atmospheric Pressure Photoionization (APPI) Coupled with 15 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) and a Comparison to Conventional Oil
    Bae, EunJung
    Na, Jeong-Geol
    Chung, Soo Hyun
    Kim, Hyun Sik
    Kim, Sunghwan
    [J]. ENERGY & FUELS, 2010, 24 (04) : 2563 - 2569
  • [7] Effects of Extraction pH on the Fourier Transform Ion Cyclotron Resonance Mass Spectrometry Profiles of Athabasca Oil Sands Process Water
    Barrow, Mark P.
    Peru, Kerry M.
    McMartin, Dena W.
    Headley, John V.
    [J]. ENERGY & FUELS, 2016, 30 (05) : 3615 - 3621
  • [8] Analysis of Geologically Relevant Metal Porphyrins Using Trapped Ion Mobility Spectrometry Mass Spectrometry and Theoretical Calculations
    Benigni, Paolo
    Bravo, Carlos
    Quirke, J. Martin E.
    DeBord, John D.
    Mebel, Alexander M.
    Fernandez-Lima, Francisco
    [J]. ENERGY & FUELS, 2016, 30 (12) : 10341 - 10347
  • [9] Increasing Polyaromatic Hydrocarbon (PAH) Molecular Coverage during Fossil Oil Analysis by Combining Gas Chromatography and Atmospheric-Pressure Laser Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS)
    Benigni, Paolo
    DeBord, J. Daniel
    Thompson, Christopher J.
    Gardinali, Piero
    Fernandez-Lima, Francisco
    [J]. ENERGY & FUELS, 2016, 30 (01) : 196 - 203
  • [10] Targeted High-Resolution Ion Mobility Separation Coupled to Ultrahigh-Resolution Mass Spectrometry of Endocrine Disruptors in Complex Mixtures
    Benigni, Paolo
    Thompson, Christopher J.
    Ridgeway, Mark E.
    Park, Melvin A.
    Fernandez-Lima, Francisco
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (08) : 4321 - 4325