Determination of polycyclic aromatic hydrocarbons in soil, tree leaves, and water samples by magnetic dispersive solid-phase extraction based on β-cyclodextrin functionalized graphene oxide followed by GC-FID

被引:26
作者
Majd, Mahshid [1 ]
Nojavan, Saeed [1 ]
机构
[1] Shahid Beheshti Univ, Dept Analyt Chem & Pollutants, Tehran 1983969411, Iran
关键词
beta-Cyclodextrin; Environmental samples; Hexamethylene diisocyanate; Magnetic dispersive solid-phase extraction; Polycyclic aromatic hydrocarbons; METAL-ORGANIC FRAMEWORK; PERFORMANCE LIQUID-CHROMATOGRAPHY; SORBENT; NANOPARTICLES; MICROSPHERES; PAHS; MEMBRANE; REMOVAL; ACID;
D O I
10.1016/j.microc.2021.106852
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance sorbent was synthesized and used to extract some polycyclic aromatic hydrocarbons (naphthalene, acenaphthene, fluorene, phenanthrene, fluoranthene, pyrene, benzo[a]pyrene) from environmental samples by using magnetic dispersive solid-phase extraction (MdSPE) procedure followed by a gas chromatography-flame ionization detector (GC-FID). The sorbent was synthesized by grafting beta-cyclodextrin (beta-CD) onto magnetic graphene oxide (MGO) via hexamethylene diisocyanate (HMDI) as a linker. Prepared magnetic sorbent (MGO/HMDI/beta-CD) was characterized by Fourier transform infrared spectroscopy (FT-IR), the field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), the X-ray diffraction (XRD), vibrating-sample magnetometer (VSM), thermogravimetric analysis (TGA), and energydispersive X-ray spectroscopy. The variables that affect the performance of the extraction method were investigated in detail and thoroughly optimized using experimental design and response surface methodology. Under the optimum conditions (sorbent amount: 25 mg, extraction time: 20 min, concentration of NaCl: 27% (w/v), desorption time: 6 min, volume of desorption solvent: 300 mu L, and desorption solvent: toluene), enrichment factors were obtained between 46 and 62. The results indicated that the extraction recoveries of these compounds were in the range of 73.0-97.1%. Good linearity within the range of 5.0-1000.0 ng/mL with coefficients of determination higher than 0.984 was achieved. Detection limits were found to be 0.1-0.5 ng/mL, while the relative standard deviations (RSDs) were calculated to be <= 8.0% (n = 3). The fabricated sorbent was successfully applied for the extraction and quantification of PAHs in pretreated environmental samples (soil, tree leaves, and river water).
引用
收藏
页数:11
相关论文
共 50 条
[41]   Quantitative determination of 16 polycyclic aromatic hydrocarbons in soil samples using solid-phase microextraction [J].
Wang, Yonghua ;
Zhang, Juan ;
Ding, Youchao ;
Zhou, Jia ;
Ni, Lixiao ;
Sun, Cheng .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (22) :3951-3957
[42]   Magnetic Graphene-Dispersive Solid-Phase Extraction for Preconcentration and Determination of Lead and Cadmium in Dairy Products and Water Samples [J].
Ezoddin, M. ;
Majidi, B. ;
Abdi, K. ;
Lamei, N. .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2015, 95 (06) :830-835
[43]   Optimization of a Solid-Phase Extraction Method Using Centrifugation for the Determination of 16 Polycyclic Aromatic Hydrocarbons in Water [J].
Kouzayha, Abir ;
Al Iskandarani, Mohamad ;
Mokh, Samia ;
Rabaa, Abdul Rahman ;
Budzinski, Helene ;
Jaber, Farouk .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (14) :7592-7600
[44]   Determination of 15 polycyclic aromatic hydrocarbons in aquatic products by solid-phase extraction and GC-MS [J].
Liu, Qiying ;
Guo, Yuanming ;
Sun, Xiumei ;
Hao, Qing ;
Cheng, Xin ;
Zhang, Lu .
JOURNAL OF SEPARATION SCIENCE, 2018, 41 (10) :2188-2196
[45]   Three-dimensional ionic liquid functionalized magnetic graphene oxide nanocomposite for the magnetic dispersive solid phase extraction of 16 polycyclic aromatic hydrocarbons in vegetable oils [J].
Zhang, Yun ;
Zhou, Hua ;
Zhang, Zhe-Hua ;
Wu, Xiang-Lun ;
Chen, Wei-Guo ;
Zhu, Yan ;
Fang, Chun-Fu ;
Zhao, Yong-Gang .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1489 :29-38
[46]   Portable micro-solid phase extraction for the determination of polycyclic aromatic hydrocarbons in water samples [J].
Abidin, Nurul Nabilah Zainal ;
Sanagi, Mohd Marsin ;
Ibrahim, Wan Aini Wan ;
Endud, Salasiah ;
Shukri, Dyia Syaleyana Md .
ANALYTICAL METHODS, 2014, 6 (15) :5512-5518
[47]   Magnetic Polyeugenol Nanoparticles as a New Sorbent for Solid-Phase Extraction of Polycyclic Aromatic Hydrocarbons in Environmental Water and Food Samples [J].
Rezaei, Mahdie ;
Mehdinia, Ali ;
Shemirani, Farzaneh .
CHEMISTRYSELECT, 2023, 8 (11)
[48]   Solid-phase microextraction with a graphene-composite-coated fiber coupled with GC for the determination of some halogenated aromatic hydrocarbons in water samples [J].
Zhang, Guijiang ;
Li, Zhi ;
Zang, Xiaohuan ;
Wang, Chun ;
Wang, Zhi .
JOURNAL OF SEPARATION SCIENCE, 2014, 37 (04) :440-446
[49]   Magnetic solid-phase extraction of polycyclic aromatic hydrocarbons in water samples by Fe3O4@polypyrrole/carbon nanotubes [J].
Abdar, Abbas ;
Sarafraz-Yazdi, Ali ;
Amiri, Amirhassan ;
Bagheri, Navid .
JOURNAL OF SEPARATION SCIENCE, 2016, 39 (14) :2746-2753
[50]   Facile magnetization of metal-organic framework MIL-101 for magnetic solid-phase extraction of polycyclic aromatic hydrocarbons in environmental water samples [J].
Huo, Shu-Hui ;
Yan, Xiu-Ping .
ANALYST, 2012, 137 (15) :3445-3451