Determination of polycyclic aromatic hydrocarbons in soil, tree leaves, and water samples by magnetic dispersive solid-phase extraction based on β-cyclodextrin functionalized graphene oxide followed by GC-FID

被引:26
作者
Majd, Mahshid [1 ]
Nojavan, Saeed [1 ]
机构
[1] Shahid Beheshti Univ, Dept Analyt Chem & Pollutants, Tehran 1983969411, Iran
关键词
beta-Cyclodextrin; Environmental samples; Hexamethylene diisocyanate; Magnetic dispersive solid-phase extraction; Polycyclic aromatic hydrocarbons; METAL-ORGANIC FRAMEWORK; PERFORMANCE LIQUID-CHROMATOGRAPHY; SORBENT; NANOPARTICLES; MICROSPHERES; PAHS; MEMBRANE; REMOVAL; ACID;
D O I
10.1016/j.microc.2021.106852
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance sorbent was synthesized and used to extract some polycyclic aromatic hydrocarbons (naphthalene, acenaphthene, fluorene, phenanthrene, fluoranthene, pyrene, benzo[a]pyrene) from environmental samples by using magnetic dispersive solid-phase extraction (MdSPE) procedure followed by a gas chromatography-flame ionization detector (GC-FID). The sorbent was synthesized by grafting beta-cyclodextrin (beta-CD) onto magnetic graphene oxide (MGO) via hexamethylene diisocyanate (HMDI) as a linker. Prepared magnetic sorbent (MGO/HMDI/beta-CD) was characterized by Fourier transform infrared spectroscopy (FT-IR), the field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), the X-ray diffraction (XRD), vibrating-sample magnetometer (VSM), thermogravimetric analysis (TGA), and energydispersive X-ray spectroscopy. The variables that affect the performance of the extraction method were investigated in detail and thoroughly optimized using experimental design and response surface methodology. Under the optimum conditions (sorbent amount: 25 mg, extraction time: 20 min, concentration of NaCl: 27% (w/v), desorption time: 6 min, volume of desorption solvent: 300 mu L, and desorption solvent: toluene), enrichment factors were obtained between 46 and 62. The results indicated that the extraction recoveries of these compounds were in the range of 73.0-97.1%. Good linearity within the range of 5.0-1000.0 ng/mL with coefficients of determination higher than 0.984 was achieved. Detection limits were found to be 0.1-0.5 ng/mL, while the relative standard deviations (RSDs) were calculated to be <= 8.0% (n = 3). The fabricated sorbent was successfully applied for the extraction and quantification of PAHs in pretreated environmental samples (soil, tree leaves, and river water).
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Solid-Phase Microextraction of Phthalate Esters from Aqueous Media by Functionalized Carbon Nanotubes (Graphene Oxide Nanoribbons) and Determination by GC-FID
    Kazemi, Maryam
    Niazi, Ali
    Yazdanipour, Atisa
    [J]. CHROMATOGRAPHIA, 2021, 84 (06) : 559 - 569
  • [32] Dispersive solid-phase extraction based on β-cyclodextrin grafted hyperbranched polymers for determination of pyrethroids in environmental water samples
    Mi, Yiduo
    Jia, Chendi
    Lin, Xiwen
    Liu, Xinya
    Zhang, Sanbing
    Zhou, Wenfeng
    Gao, Haixiang
    Lu, Runhua
    [J]. MICROCHEMICAL JOURNAL, 2019, 150
  • [33] Magnetic fiber headspace solid-phase microextraction coupled to GC-MS for the extraction and quantitation of polycyclic aromatic hydrocarbons
    Rasolzadeh, Fahimeh
    Hashemi, Payman
    [J]. MICROCHIMICA ACTA, 2019, 186 (07)
  • [34] Preparation and Evaluation of a Novel Solid-Phase Microextraction Fiber Based on Functionalized Nanoporous Silica Coating for Extraction of Polycyclic Aromatic Hydrocarbons From Water Samples Followed by GC-MS Detection
    Shamsipur, Mojtaba
    Gholivand, Mohammad Bagher
    Shamizadeh, Mohammad
    Hashemi, Payman
    [J]. CHROMATOGRAPHIA, 2015, 78 (11-12) : 795 - 803
  • [35] Rapid determination of polycyclic aromatic hydrocarbons in environmental water based on magnetite nanoparticles/polypyrrole magnetic solid-phase extraction
    Xu, Sheng-Nan
    Zhao, Qin
    He, Hai-Bo
    Yuan, Bi-Feng
    Feng, Yu-Qi
    Yu, Qiong-Wei
    [J]. ANALYTICAL METHODS, 2014, 6 (17) : 7046 - 7053
  • [36] Magnetic iron-based metal organic framework as an adsorbent for magnetic dispersive solid-phase extraction of pyrene and phenanthrene in water samples
    Nourodin, Reza
    Mengelizadeh, Nezamaddin
    Hashemi, Fatemeh
    Yousefi, Majid
    Rahimpoor, Razzagh
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024,
  • [37] Micro-solid phase extraction of some polycyclic aromatic hydrocarbons from environmental water samples using magnetic β-cyclodextrin-carbon nano-tube composite as a sorbent
    Yazdanpanah, Mina
    Nojavan, Saeed
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2019, 1585 : 34 - 45
  • [38] Graphene oxide modified magnetic polyamidoamide dendrimers based magnetic solid phase extraction for sensitive measurement of polycyclic aromatic hydrocarbons
    Tong, Yayan
    Li, Shuangying
    Wu, Yalin
    Guo, Jinghan
    Zhou, Boyao
    Zhou, Qingxiang
    Jiang, Liushan
    Niu, Jingwen
    Zhang, Yue
    Liu, Huanhuan
    Yuan, Shuai
    Huang, Shiyu
    Zhan, Yali
    [J]. CHEMOSPHERE, 2022, 296
  • [39] Determination of selected pesticides by GC-FID after CNO/MOF nanocomposites-based dispersive solid phase extraction coupled with liquid microextraction
    Abbasalizadeh, Aysa
    Ghalkhani, Masoumeh
    Khosrowshahi, Elnaz Marzi
    Mazani, Alijan
    Hosseini, Asieh
    Sohouli, Esmail
    Ahmadi, Farhad
    [J]. DIAMOND AND RELATED MATERIALS, 2023, 137
  • [40] Quantitative determination of 16 polycyclic aromatic hydrocarbons in soil samples using solid-phase microextraction
    Wang, Yonghua
    Zhang, Juan
    Ding, Youchao
    Zhou, Jia
    Ni, Lixiao
    Sun, Cheng
    [J]. JOURNAL OF SEPARATION SCIENCE, 2009, 32 (22) : 3951 - 3957