Determination of polycyclic aromatic hydrocarbons in soil, tree leaves, and water samples by magnetic dispersive solid-phase extraction based on β-cyclodextrin functionalized graphene oxide followed by GC-FID

被引:25
|
作者
Majd, Mahshid [1 ]
Nojavan, Saeed [1 ]
机构
[1] Shahid Beheshti Univ, Dept Analyt Chem & Pollutants, Tehran 1983969411, Iran
关键词
beta-Cyclodextrin; Environmental samples; Hexamethylene diisocyanate; Magnetic dispersive solid-phase extraction; Polycyclic aromatic hydrocarbons; METAL-ORGANIC FRAMEWORK; PERFORMANCE LIQUID-CHROMATOGRAPHY; SORBENT; NANOPARTICLES; MICROSPHERES; PAHS; MEMBRANE; REMOVAL; ACID;
D O I
10.1016/j.microc.2021.106852
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance sorbent was synthesized and used to extract some polycyclic aromatic hydrocarbons (naphthalene, acenaphthene, fluorene, phenanthrene, fluoranthene, pyrene, benzo[a]pyrene) from environmental samples by using magnetic dispersive solid-phase extraction (MdSPE) procedure followed by a gas chromatography-flame ionization detector (GC-FID). The sorbent was synthesized by grafting beta-cyclodextrin (beta-CD) onto magnetic graphene oxide (MGO) via hexamethylene diisocyanate (HMDI) as a linker. Prepared magnetic sorbent (MGO/HMDI/beta-CD) was characterized by Fourier transform infrared spectroscopy (FT-IR), the field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), the X-ray diffraction (XRD), vibrating-sample magnetometer (VSM), thermogravimetric analysis (TGA), and energydispersive X-ray spectroscopy. The variables that affect the performance of the extraction method were investigated in detail and thoroughly optimized using experimental design and response surface methodology. Under the optimum conditions (sorbent amount: 25 mg, extraction time: 20 min, concentration of NaCl: 27% (w/v), desorption time: 6 min, volume of desorption solvent: 300 mu L, and desorption solvent: toluene), enrichment factors were obtained between 46 and 62. The results indicated that the extraction recoveries of these compounds were in the range of 73.0-97.1%. Good linearity within the range of 5.0-1000.0 ng/mL with coefficients of determination higher than 0.984 was achieved. Detection limits were found to be 0.1-0.5 ng/mL, while the relative standard deviations (RSDs) were calculated to be <= 8.0% (n = 3). The fabricated sorbent was successfully applied for the extraction and quantification of PAHs in pretreated environmental samples (soil, tree leaves, and river water).
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Simultaneous determination of 16 polycyclic aromatic hydrocarbons in groundwater by GC-FID after solid-phase extraction
    Martins Carvalho, Fabio Israel
    Dantas Filho, Heronides Adonias
    Fernandes Dantas, Kelly das Gracas
    SN APPLIED SCIENCES, 2019, 1 (07):
  • [2] Simultaneous determination of 16 polycyclic aromatic hydrocarbons in groundwater by GC-FID after solid-phase extraction
    Fábio Israel Martins Carvalho
    Heronides Adonias Dantas Filho
    Kelly das Graças Fernandes Dantas
    SN Applied Sciences, 2019, 1
  • [3] Ultrasound-assisted magnetic solid-phase extraction of polycyclic aromatic hydrocarbons and nitrated polycyclic aromatic hydrocarbons from water samples with a magnetic polyaniline modified graphene oxide nanocomposite
    Manousi, N.
    Deliyanni, E. A.
    Rosenberg, E.
    Zachariadis, G. A.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1645
  • [4] Magnetic graphene solid-phase extraction in the determination of polycyclic aromatic hydrocarbons in water
    Pang, Liling
    Zhang, Wanfeng
    Zhang, Weiya
    Chen, Pin
    Yu, Jing
    Zhu, Gang-Tian
    Zhu, Shukui
    RSC ADVANCES, 2017, 7 (85): : 53720 - 53727
  • [5] Spent tea leaves as an adsorbent for micro-solid-phase extraction of polycyclic aromatic hydrocarbons (PAHs) from water and food samples prior to GC-FID analysis
    Nazir, Nazzatul Atirah Mohd
    Raoov, Muggundha
    Mohamad, Sharifah
    MICROCHEMICAL JOURNAL, 2020, 159
  • [6] Magnetic poly(β-cyclodextrin-ionic liquid) nanocomposites for micro-solid phase extraction of selected polycyclic aromatic hydrocarbons in rice samples prior to GC-FID analysis
    Boon, Yih Hui
    Zain, Nur Nadhirah Mohamad
    Mohamad, Sharifah
    Osman, Hasnah
    Raoov, Muggundha
    FOOD CHEMISTRY, 2019, 278 : 322 - 332
  • [7] Magnetic hybrid support for ultrasound-assisted magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from produced water
    Lima de Barros Gaetano, Vinicius Crispim
    Cunha, Graziele da Costa
    Matos Oliveira, Rhayza Victoria
    Alexandre, Marcelo da Rosa
    Cruz Romao, Luciane Pimenta
    MICROCHEMICAL JOURNAL, 2019, 146 : 1195 - 1203
  • [8] Poly(cyclodextrin-ionic liquid) based ferrofluid: A new class of magnetic colloid for dispersive liquid phase microextraction of polycyclic aromatic hydrocarbons from food samples prior to GC-FID analysis
    Hui, Boon Yih
    Zain, Nur Nadhirah Mohamad
    Mohamad, Sharifah
    Varanusupakul, Puttaruksa
    Osman, Hasnah
    Raoov, Muggundha
    FOOD CHEMISTRY, 2020, 314 (314)
  • [9] Magnetic solid-phase extraction based on [60]fullerene functionalization of magnetic nanoparticles for the determination of sixteen polycyclic aromatic hydrocarbons in tea samples
    Zhou, Dian-Bing
    Sheng, Xuan
    Han, Fang
    Hu, Yan-Yun
    Ding, Lei
    Lv, Ya-Ling
    Song, Wei
    Zheng, Ping
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1578 : 53 - 60
  • [10] Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hydrocarbons determination in water samples
    Mauri-Aucejo, Adela
    Amoros, Pedro
    Moragues, Alaina
    Guillem, Carmen
    Belenguer-Sapina, Carolina
    TALANTA, 2016, 156 : 95 - 103