Review of extremity dosimetry in nuclear medicine

被引:18
|
作者
Kollaard, Robert [1 ]
Zorz, Alessandra [2 ]
Dabin, Jeremie [3 ]
Covens, Peter [4 ]
Cooke, Jennie [5 ]
Crabbe, Melissa [3 ]
Cunha, Lidia [6 ]
Dowling, Anita [7 ]
Ginjaume, Merce [8 ]
McNamara, Leanne [9 ]
机构
[1] Nucl Res & Consultancy Grp NRG, Consultancy & Serv Div, Dept Radiat Protect, Arnhem, Netherlands
[2] Veneto Inst Oncol IOV IRCCS, Dept Med Phys, Padua, Italy
[3] Belgian Nucl Res Ctr SCK CEN, Res Dosimetr Applicat, Mol, Belgium
[4] Vrije Univ Brussel VUB, Vivo Cellular & Mol Imaging, Brussels, Belgium
[5] St James Hosp, Dept Med Phys, Dublin, Ireland
[6] IsoPor Azores, Dept Nucl Med, Angra Do Heroismo, Portugal
[7] St Vincents Univ Hosp, Dept Med Phys & Clin Engn, Dublin, Ireland
[8] Univ Politecn Cataluna, Inst Tecn Energet, Barcelona, Spain
[9] Univ Hosp Limerick, Dept Med Phys, Limerick, Ireland
关键词
nuclear medicine; extremity dosimetry; skin dose; finger dose; individual monitoring; contamination; BETA-RADIATION EXPOSURE; RADIONUCLIDE THERAPY; HAND EXPOSURE; WHOLE-BODY; IONIZING-RADIATION; PERSONNEL; STAFF; SKIN; RADIOPHARMACEUTICALS; PROTECTION;
D O I
10.1088/1361-6498/ac31a2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The exposure of the fingers is one of the major radiation protection concerns in nuclear medicine (NM). The purpose of this paper is to provide an overview of the exposure, dosimetry and protection of the extremities in NM. A wide range of reported finger doses were found in the literature. Historically, the highest finger doses are found at the fingertip in the preparation and dispensing of F-18 for diagnostic procedures and Y-90 for therapeutic procedures. Doses can be significantly reduced by following recommendations on source shielding, increasing distance and training. Additionally, important trends contributing to a lower dose to the fingers are the use of automated procedures (especially for positron emission tomography (PET)) and the use of prefilled syringes. On the other hand, the workload of PET procedures has substantially increased during the last ten years. In many cases, the accuracy of dose assessment is limited by the location of the dosimeter at the base of the finger and the maximum dose at the fingertip is underestimated (typical dose ratios between 1.4 and 7). It should also be noted that not all dosimeters are sensitive to low-energy beta particles and there is a risk for underestimation of the finger dose when the detector or its filter is too thick. While substantial information has been published on the most common procedures (using Tc-99m, F-18 and Y-90), less information is available for more recent applications, such as the use of Ga-68 for PET imaging. Also, there is a need for continuous awareness with respect to contamination of the fingers, as this factor can contribute substantially to the finger dose.
引用
收藏
页码:R60 / R87
页数:28
相关论文
共 50 条
  • [41] Assessment of extremity occupational exposure at a nuclear medicine department
    Khouqeer, Ghada Ahmed
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (01) : 257 - 261
  • [42] Eighth symposium on neutron dosimetry - Advances in nuclear particle dosimetry for radiation protection and medicine
    不详
    PTB-MITTEILUNGEN, 1996, 106 (02): : 142 - 142
  • [43] Advances in nuclear particle dosimetry for radiation protection and medicine - Ninth Symposium on Neutron Dosimetry
    Zoetelief, J
    Bos, AJJ
    Schuhmacher, H
    McDonald, JC
    Schultz, FW
    Pihet, P
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 1 - 3
  • [44] Nuclear Medicine Eye Dosimetry: Preliminary Results from a UK Nuclear Medicine and PET/CT centre
    Havariyoun, G.
    Branco, M. N.
    Clinch, P.
    Kalogianni, E.
    Mistry, A.
    Ruiz, D.
    Vivian, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S200 - S200
  • [45] Radionuclides Used in Nuclear Medicine Therapy - From Production to Dosimetry
    Lyra, Maria E.
    Andreou, Maria
    Georgantzoglou, Antonios
    Kordolaimi, Sofia
    Lagopati, Nefeli
    Ploussi, Agapi
    Salvara, Aikaterini-Lampro
    Vamvakas, Ioannis
    CURRENT MEDICAL IMAGING, 2013, 9 (01) : 51 - 75
  • [46] Dosimetry in a nuclear medicine department: an instrument to evaluate radiation protection
    De Geest, E.
    Bricoult, M.
    Van Cauteren, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S125 - S125
  • [47] COMPUTED TOMOGRAPHIC PRACTICE AND DOSIMETRY - IMPLICATIONS FOR NUCLEAR-MEDICINE
    MOUNTFORD, PJ
    HARDING, LK
    NUCLEAR MEDICINE COMMUNICATIONS, 1992, 13 (11) : 781 - 782
  • [48] RADIATION-DOSIMETRY IN NUCLEAR-MEDICINE - RECENT DEVELOPMENTS
    HETHERINGTON, ELR
    WOOD, NR
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1975, 5 (04): : 380 - 380
  • [49] RADAR Commentary: Evolution and Current Status of Dosimetry in Nuclear Medicine
    Stabin, Michael G.
    Sharkey, Robert M.
    Siegel, Jeffry A.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (07) : 1156 - 1161
  • [50] OpenDose: Open-Access Resource for Nuclear Medicine Dosimetry
    Chauvin, Maxime
    Borys, Damian
    Botta, Francesca
    Bzowski, Pawel
    Dabin, Jeremie
    Denis-Bacelar, Ana M.
    Desbree, Aurelie
    Falzone, Nadia
    Lee, Boon Quan
    Mairani, Andrea
    Malaroda, Alessandra
    Mathieu, Gilles
    McKay, Erin
    Mora-Ramirez, Erick
    Robinson, Andrew P.
    Sarrut, David
    Struelens, Lara
    Gil, Alex Vergara
    Bardies, Manuel
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (10) : 1514 - 1519