Review of extremity dosimetry in nuclear medicine

被引:18
|
作者
Kollaard, Robert [1 ]
Zorz, Alessandra [2 ]
Dabin, Jeremie [3 ]
Covens, Peter [4 ]
Cooke, Jennie [5 ]
Crabbe, Melissa [3 ]
Cunha, Lidia [6 ]
Dowling, Anita [7 ]
Ginjaume, Merce [8 ]
McNamara, Leanne [9 ]
机构
[1] Nucl Res & Consultancy Grp NRG, Consultancy & Serv Div, Dept Radiat Protect, Arnhem, Netherlands
[2] Veneto Inst Oncol IOV IRCCS, Dept Med Phys, Padua, Italy
[3] Belgian Nucl Res Ctr SCK CEN, Res Dosimetr Applicat, Mol, Belgium
[4] Vrije Univ Brussel VUB, Vivo Cellular & Mol Imaging, Brussels, Belgium
[5] St James Hosp, Dept Med Phys, Dublin, Ireland
[6] IsoPor Azores, Dept Nucl Med, Angra Do Heroismo, Portugal
[7] St Vincents Univ Hosp, Dept Med Phys & Clin Engn, Dublin, Ireland
[8] Univ Politecn Cataluna, Inst Tecn Energet, Barcelona, Spain
[9] Univ Hosp Limerick, Dept Med Phys, Limerick, Ireland
关键词
nuclear medicine; extremity dosimetry; skin dose; finger dose; individual monitoring; contamination; BETA-RADIATION EXPOSURE; RADIONUCLIDE THERAPY; HAND EXPOSURE; WHOLE-BODY; IONIZING-RADIATION; PERSONNEL; STAFF; SKIN; RADIOPHARMACEUTICALS; PROTECTION;
D O I
10.1088/1361-6498/ac31a2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The exposure of the fingers is one of the major radiation protection concerns in nuclear medicine (NM). The purpose of this paper is to provide an overview of the exposure, dosimetry and protection of the extremities in NM. A wide range of reported finger doses were found in the literature. Historically, the highest finger doses are found at the fingertip in the preparation and dispensing of F-18 for diagnostic procedures and Y-90 for therapeutic procedures. Doses can be significantly reduced by following recommendations on source shielding, increasing distance and training. Additionally, important trends contributing to a lower dose to the fingers are the use of automated procedures (especially for positron emission tomography (PET)) and the use of prefilled syringes. On the other hand, the workload of PET procedures has substantially increased during the last ten years. In many cases, the accuracy of dose assessment is limited by the location of the dosimeter at the base of the finger and the maximum dose at the fingertip is underestimated (typical dose ratios between 1.4 and 7). It should also be noted that not all dosimeters are sensitive to low-energy beta particles and there is a risk for underestimation of the finger dose when the detector or its filter is too thick. While substantial information has been published on the most common procedures (using Tc-99m, F-18 and Y-90), less information is available for more recent applications, such as the use of Ga-68 for PET imaging. Also, there is a need for continuous awareness with respect to contamination of the fingers, as this factor can contribute substantially to the finger dose.
引用
收藏
页码:R60 / R87
页数:28
相关论文
共 50 条
  • [31] Dosimetry of Internal Emitters in Nuclear Medicine and Radiation Protection
    Sundararajan, A. R.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (03) : 166 - 167
  • [32] MEASUREMENT OF OPERATIONAL DOSIMETRY QUANTITIES FOR NUCLEAR MEDICINE STAFF
    Dehghan, Nahid
    Sina, Sedigheh
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (02) : 119 - 124
  • [33] USE OF MAGIC GEL FOR DIAGNOSTIC NUCLEAR MEDICINE DOSIMETRY
    Bourbia, Nadjla
    Mansour, Karim
    ACTA PHYSICA POLONICA B, 2016, 47 (02): : 315 - 321
  • [34] Dosimetry in nuclear medicine therapy: radiobiology application and results
    Strigari, L.
    Benassi, M.
    Chiesa, C.
    Cremonesi, M.
    Bodei, L.
    D'Andrea, M.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 55 (02): : 205 - 221
  • [35] OpenDose: Generating reference data for Nuclear Medicine dosimetry
    Chauvin, M.
    Borys, D.
    Botta, F.
    Bzowski, P.
    Coca Perez, M. A.
    Cremonesi, M.
    Dabin, J.
    Denis-Bacelar, A. M.
    Desbree, A.
    El Bitar, Z.
    Falzone, N.
    Ferrer, L.
    Franck, D.
    Lanconelli, N.
    Mairani, A.
    Malaroda, A.
    Matusik, K.
    Mckay, E.
    Pacilio, M.
    Pieter, J.
    Rodriguez, J. L.
    Struelens, L.
    Torres Aroches, L. A.
    Vergara Gil, A.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S807 - S807
  • [36] RADIONUCLIDE BIOKINETICS AND INTERNAL DOSIMETRY IN NUCLEAR-MEDICINE
    KAUL, A
    HENRICHS, K
    ROEDLER, HD
    RICERCA IN CLINICA E IN LABORATORIO, 1980, 10 (04): : 629 - 662
  • [37] OpenDose: open access resources for Nuclear Medicine dosimetry
    Chauvin, Maxime
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [38] Nuclear medicine dosimetry: Quantitative imaging and dose calculations
    Glatting, Gerhard
    Lassmann, Michael
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (04): : 246 - 247
  • [39] Uncertainty and sensitivity analysis in nuclear medicine imaging and dosimetry
    Li, Wei Bo
    Ziegler, Sibylle
    Zankl, Maria
    Hoeschen, Christoph
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [40] Extremity exposure in Nuclear Medicine: outcome of the ORAMED project
    Merce, M. Sans
    Barth, I.
    Carnicer, A.
    Donadille, L.
    Ferrari, P.
    Fulop, M.
    Ginjaume, M.
    Gualdrini, G.
    Krim, S.
    Mariotti, F.
    Ortega, X.
    Rimpler, A.
    Ruiz, N.
    Vanhavere, F.
    Baechler, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S186 - S186