Modified Dipole Antenna For Directional Microwave Ablation Using 3D Numerical Simulation

被引:0
作者
Alnassan, Hussein [1 ,2 ]
Kastler, Adrian [1 ]
Wang, Xia [1 ]
Kastler, Bruno [1 ,3 ]
机构
[1] Univ Franche Comte, IFR 133, Lab I4S EA 4268, Besancon, France
[2] Aleppo Univ, E&E Engn Fac, Aleppo, Syria
[3] Univ Hosp, Intervent Radiol Unit, Strasbourg, France
来源
2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON) | 2014年
关键词
Microwave ablation; liver tumors; targeted directional radiation; LIVER; LUNG; BONE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Microwave ablation has several medical applications including liver, kidney, bone and lung. Numerical simulation of microwave ablation is a step in the implementation of system design. This paper presents the temperature distribution of targeted radiation dipole antenna for microwave ablation at 2.45GHz. This experiment through the temperature profile around the antenna achieves in the range 50W, 60W and 70W. In addition, we set the ablation time in the range 300s, 600s and 900s. The goal of this work is to develop a device for directional tumor ablation avoiding destruction of neural structures.
引用
收藏
页数:4
相关论文
共 16 条
  • [1] Microwave ablation with a single small-gauge triaxial antenna: In vivo porcine liver model
    Brace, Christopher L.
    Laeseke, Paul F.
    Sampson, Lisa A.
    Frey, Tina M.
    van der Weide, Daniel W.
    Lee, Fred T., Jr.
    [J]. RADIOLOGY, 2007, 242 (02) : 435 - 440
  • [2] Radiofrequency and Microwave Ablation of the Liver, Lung, Kidney, and Bone: What Are the Differences?
    Brace, Christopher L.
    [J]. CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2009, 38 (03) : 135 - 143
  • [3] Initial Experience Using Microwave Ablation Therapy for Renal Tumor Treatment: 18-Month Follow-up
    Castle, Scott M.
    Salas, Nelson
    Leveillee, Raymond J.
    [J]. UROLOGY, 2011, 77 (04) : 792 - 797
  • [4] A Minimally Invasive Antenna for Microwave Ablation Therapies: Design, Performances, and Experimental Assessment
    Cavagnaro, Marta
    Amabile, Claudio
    Bernardi, Paolo
    Pisa, Stefano
    Tosoratti, Nevio
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (04) : 949 - 959
  • [5] Computational modelling of microwave tumour ablations
    Chiang, Jason
    Wang, Peng
    Brace, Christopher L.
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2013, 29 (04) : 308 - 317
  • [6] A DIPOLE ANTENNA FOR INTERSTITIAL MICROWAVE HYPERTHERMIA
    HURTER, W
    REINBOLD, F
    LORENZ, WJ
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1991, 39 (06) : 1048 - 1054
  • [7] Ito K, 2004, P ANN INT IEEE EMBS, V26, P2526
  • [8] Kastler A., J VASC INTERV RADIOL
  • [9] Analgesic Effects of Microwave Ablation of Bone and Soft Tissue Tumors Under Local Anesthesia
    Kastler, Adrian
    Alnassan, Hussein
    Pereira, Philippe L.
    Alemann, Guillaume
    Barbe, Daniel-Ange
    Aubry, Sebastien
    Tiberghien, Florence
    Kastler, Bruno
    [J]. PAIN MEDICINE, 2013, 14 (12) : 1873 - 1881
  • [10] Liver cancer: Increased microwave delivery to ablation zone with ooled shaft antenna - Experimental and clinical studies
    Kuang, Ming
    Lu, Ming D.
    Xie, Xiao Y.
    Xu, Hui X.
    Mo, Li Q.
    Liu, Guang J.
    Xu, Zuo F.
    Zheng, Yan L.
    Liang, Jin Y.