Flexural Behavior of a Precast Concrete Deck Connected with Headed GFRP Rebars and UHPC

被引:12
作者
Chin, Won Jong [1 ,2 ]
Park, Young Hwan [2 ]
Cho, Jeong-Rae [2 ]
Lee, Jin-Young [3 ]
Yoon, Young-Soo [1 ]
机构
[1] Korea Univ, Sch Civil Environm & Architectural Engn, Seoul 02841, South Korea
[2] Korea Inst Civil Engn & Bldg Technol, Dept Infrastruct Safety Res, Goyang 10223, South Korea
[3] Kyungpook Natl Univ, Sch Agr Civil & Bioind Engn, Daegu 41566, South Korea
关键词
glass fiber-reinforced polymer (GFRP) rebar; ultra-high-performance concrete (UHPC); concrete headed GFRP rebar; bond strength; development length; flexural strength; precast concrete deck; BOND STRENGTH;
D O I
10.3390/ma13030604
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Steel bent reinforcing bars (rebars) are widely used to provide adequate anchorage. Bent fiber-reinforced polymer (FRP) rebars are rarely used because of the difficulty faced during the bending process of the FRP rebars at the construction site. Additionally, the bending process may cause a significant decrease in the structural performance of the FRP rebars. Therefore, to overcome these drawbacks, a headed glass fiber-reinforced polymer (GFRP) rebar was developed in this study. The pull-out tests of the headed GFRP rebars with diameters of 16 and 19 mm were conducted to evaluate their bond properties in various cementitious materials. Moreover, structural flexural tests were conducted on seven precast concrete decks connected with the headed GFRP rebars and various cementitious fillers to estimate the flexural behavior of the connected decks. The results demonstrate that the concrete decks connected with the headed GFRP rebar and ultra-high-performance concrete (UHPC) exhibited improved flexural performance.
引用
收藏
页数:15
相关论文
共 12 条
  • [1] AASHTO, 2009, BRIDGE DESIGN GUIDE
  • [2] *AM CONCR I, 2006, 440 ACI COMM
  • [3] ASTM International, 2012, ASTM C39: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
  • [4] Evaluation of Physical and Durability Characteristics of New Headed Glass Fiber-Reinforced Polymer Bars for Concrete Structures
    Benmokrane, Brahim
    Mohamed, Hamdy M.
    Manalo, Allan
    Cousin, Patrice
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (02)
  • [5] Cho J.-R., 2017, P ASEM17 2017 WORLD
  • [6] Bond strength of glass fiber reinforced polymer ribbed rebars in normal strength concrete
    Hao, Qingduo
    Wang, Yanlei
    He, Zheng
    Ou, Jinping
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (02) : 865 - 871
  • [7] Korea Concrete Institute, 2019, DES GUID FRP REINF C
  • [8] Pullout behaviour of GFRP bars with anchor head in geopolymer concrete
    Maranan, G. B.
    Manalo, A. C.
    Karunasena, W.
    Benmokrane, B.
    [J]. COMPOSITE STRUCTURES, 2015, 132 : 1113 - 1121
  • [9] Bond strength of fiber reinforced polymer rebars in normal strength concrete
    Okelo, R
    Yuan, RL
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (03) : 203 - 213
  • [10] Flexural Testing of Precast Bridge Deck Panel Connections
    Porter, Scott D.
    Julander, J. Logan
    Halling, Marvin W.
    Barr, Paul J.
    Boyle, Hugh
    Xing, Shutao
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2011, 16 (03) : 422 - 430