Low current (<10A) dc measurements of the transformer windings show a uniform decrease in the resistance as the tapchanger selector switch is advanced from the first tap to the last tap. When the resistance data for a newly manufactured transformer is plotted vs. the odd and even tap positions on its primary windings, the data lies with some small, but acceptable variation, on the same straight line with a slope of - 3.9 for each of the three phases. After 20 months in operation there is a considerable change in the measured resistance data. The data for the odd and even tap positions each still lie with more variation on a line with the same slope (- 3.9), but they lie on quite different lines. In Phase-1 the difference between the data for the odd and even tap positions is about 14.2m Omega. The other two phases also show a difference, but are somewhat less than that on Phase-1. The analysis of this data shows that these differences do not imply that there is an internal problem with the transformer windings or with the internal bolted connections to those windings. Tarnish film formation on the Cu and W-Cu contacts in a transformer oil environment is discussed. These resistive films grow thicker with time and their growth on the tapchanger's selector switch and its diverter switch contacts adequately account for the difference seen in the resistance measurement between the new transformer and after it had been in operation for 20 months. A discussion of the rupture of these resistive films by the combination of high contact forces and the transformer's normal load current is also presented.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] EFFECT OF H2S CONTACTS.
    Shimosato, Shoichi
    Electronics and Communications in Japan (English translation of Denshi Tsushin Gakkai Zasshi), 1972, 55 (03): : 73 - 79
  • [2] Stability of transformer's whole low voltage winding
    Liang, ZG
    Tang, RY
    Wang, C
    Hu, HX
    ICEMS 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1 AND 2, 2003, : 302 - 304
  • [3] DC low current Hall effect measurements
    Namia-Cohen, Yannai
    Sharon, Yossi
    Khachatryan, Bagrat
    Cheskis, Dima
    2018 IEEE INTERNATIONAL CONFERENCE ON THE SCIENCE OF ELECTRICAL ENGINEERING IN ISRAEL (ICSEE), 2018,
  • [4] SELF-BLOCKING TUNNEL CURRENTS AND CURRENT-VOLTAGE CHARACTERISTICS OF S-I-S TUNNEL CONTACTS.
    Seminozhenko, V.P.
    1978, 4 (07): : 411 - 416
  • [5] Analysis of Structural Behavior of Transformer's Winding Under Inrush Current Conditions
    Fonseca, Wellington Silva
    Lima, Diorge Souza
    Ferreira Lima, Adry Kleber
    Alves Nunes, Marcus Vinicius
    Bezerra, Ubiratan Holanda
    Soeiro, Newton Sure
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (03) : 2285 - 2294
  • [6] Zeroing Transformer's DC Current in Resonant Converters with No Series Capacitors
    Gertsman, Alexander
    Ben-Yaakov, Sam
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 4028 - 4034
  • [7] Investigation of Frequency Characteristics and Effect on Winding Equivalent Resistance of Circulating Current in Medium-Frequency Transformer
    Wang R.
    Zhao Z.
    Xiao F.
    Zhang X.
    Yang G.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 : 251 - 258
  • [8] Application of saturable magnetic circuit method to measuring the DC resistance of low voltage winding of large-size transformer
    Wang, Lang-Zhu
    Yao, Yi-Ping
    Gaoya Dianqi/High Voltage Apparatus, 2003, 39 (02):
  • [9] Influence of voltage contacts on precision measurements of the quantized Hall resistance: An effect of externally injected current
    Singapore Productivity and Standards, Board, Singapore, Singapore
    IEEE Trans Instrum Meas, 2 (592-594):
  • [10] Influence of voltage contacts on precision measurements of the quantized Hall resistance: An effect of externally injected current
    Chen, TP
    Chua, HA
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (02) : 592 - 594