New Sensitive and Quantitative Analysis Method for Organic Nitrogen Compounds in Urban Aerosol Samples

被引:43
|
作者
Oezel, Mustafa Z. [1 ]
Hamilton, Jacqueline F.
Lewis, Alastair C. [1 ]
机构
[1] Univ York, Dept Chem, Natl Ctr Atmospher Sci, York YO10 5DD, N Yorkshire, England
基金
英国自然环境研究理事会;
关键词
FLIGHT MASS-SPECTROMETRY; GAS-CHROMATOGRAPHY; CHEMILUMINESCENCE; TOLUENE; NITROSAMINES; PHOSPHORUS; SPECIATION; NITRILES;
D O I
10.1021/es102528g
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Atmospheric aerosols contain a highly complex mixture of organic and inorganic compounds; however, as a chemical class relatively little is known about organic nitrogen (ON) content, with few satisfactory methods for speciated analysis. In this paper we report a sensitive and quantitative method for the speciation of ON within ambient atmospheric aerosol. Aerosol samples, collected on quartz microfiber filters, were extracted in water followed by solid phase extraction, elution, and concentration before analysis by comprehensive gas chromatography with a nitrogen chemiluminescence detection system (GCxGC-NCD). The NCD detection method was optimized using liquid standards. The GCxGC-NCD method showed high selectivity, sensitivity, and equimolarity in its response to individual organic compounds. Limits of detection (LOD) and limits of quantitation (LOQ) for four ON standards (1-nitropentane, o-toluidine, nonanenitrile, and quinoline) were determined to be in the range 0.16-0.27 pgN and 0.71-1.19 pgN, respectively. Between 21 and 57 different ON compounds were found in urban aerosol, (including 10 nitriles, 9 alkyl nitro compounds, 4 nitro-phenols, 4 amides, 3 nitrosamines, and 2 nitro-PAHs) on different dates from a city center location. Pyrrole (8.26-39.21 ngN m(-3) air) and N-butyl-benzenesulfonamide (6.23-20.87 ngN m(-3) air) were the most abundant ON compounds observed in all samples analyzed. The average mass loading of the total identified ON was 532.51 ngON m(-3) air. The sensitivity, selectivity, and relative ease of quantitation of unknown ON components makes the technique a significant improvement over previous laboratory methods.
引用
收藏
页码:1497 / 1505
页数:9
相关论文
共 50 条
  • [31] GC/MS with Post-Column Switching for Large Volume Injection of Headspace Samples: Sensitive Determination of Volatile Organic Compounds in Human Whole Blood and Urine
    Watanabe, Kanako
    Fujita, Hiroki
    Hasegawa, Koutaro
    Gonmori, Kunio
    Suzuki, Osamu
    ANALYTICAL CHEMISTRY, 2011, 83 (04) : 1475 - 1479
  • [32] Development of pulse introduction membrane extraction for analysis of volatile organic compounds in individual aqueous samples, and for continuous on-line monitoring
    Guo, XM
    Mitra, S
    JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (01) : 39 - 47
  • [33] A new HPLC method developed for the analysis of oxygen heterocyclic compounds in Citrus essential oils
    Russo, Marina
    Torre, Germana
    Carnovale, Caterina
    Bonaccorsi, Ivana
    Mondello, Luigi
    Dugo, Paola
    JOURNAL OF ESSENTIAL OIL RESEARCH, 2012, 24 (02) : 119 - 129
  • [34] Development of a new needle trap-based method for the determination of some volatile organic compounds in the indoor environment
    Baysal, Ertan
    Uzun, Umut Can
    Ertas, Fatma Nil
    Goksel, Ozlem
    Pelit, Levent
    CHEMOSPHERE, 2021, 277
  • [35] Flux measurements of volatile organic compounds by the relaxed eddy accumulation method combined with a GC-FID system in urban Houston, Texas
    Park, Changhyoun
    Schade, Gunnar W.
    Boedeker, Ian
    ATMOSPHERIC ENVIRONMENT, 2010, 44 (21-22) : 2605 - 2614
  • [36] New in situ solvothermally synthesized metal-organic framework MOF-199 coating for solid-phase microextraction of volatile organic compounds from air samples
    Omarova, Anara
    Baizhan, Ainur
    Baimatova, Nassiba
    Kenessov, Bulat
    Kazemian, Hossein
    MICROPOROUS AND MESOPOROUS MATERIALS, 2021, 328
  • [37] Liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry: a highly sensitive method for the analysis of organic explosives
    Song, Liguo
    Bartmess, John E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (01) : 77 - 84
  • [38] Sample Preparation of Volatile Organic Compounds in Air Samples with a Novel Polyimide-Packed Cartridge Designed for the Subsequent Analysis in Capillary Gas Chromatography
    Inoue, Mitsuru
    Nakazaki, Hitomi
    Tazawa, Toshiaki
    Takeuchi, Hayato
    Kobayashi, Akira
    Ueta, Ikuo
    Shirai, Yuki
    Moriuchi, Koji
    Saito, Yoshihiro
    CHROMATOGRAPHY, 2015, 36 (01) : 33 - 37
  • [39] New approach to the fast screening of plant oil samples for F-, Cl-, Br- and S-organic compounds on the trace level
    Chivarzin, M. E.
    Revelsky, I. A.
    Nikoshina, A. V.
    Buldyzkova, A. N.
    Chepeliansky, D. A.
    Revelsky, A. I.
    Buriak, A. K.
    TALANTA, 2016, 150 : 113 - 117
  • [40] Alternative Method for Qualitative Analysis of Specific Non-volatile Organic Compounds Present in South African Water Systems
    Brutti, R.
    Magu, M. M.
    Agorku, E. S.
    Govender, P. P.
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2016, 69 : 244 - 253