摘要
We report quantitative, spatially resolved laser-saturated fluorescence (LSF), linear laser-induced fluorescence (LIF), and planar laser-induced fluorescence (PLIF) measurements of nitric oxide (NO) concentration in a preheated, lean direct-injection spray flame at atmospheric pressure. The spray is produced by a hollow-cone, pressure-atomized nozzle supplied with liquid heptane, and the overall equivalence ratio is unity. NO is excited by means of the Q(2)(26.5) transition of the gamma(0, 0) band. LSF and LIF detection are performed in a 2-nm region centered on the gamma(0, 1) band. PLIF detection is performed in a broad similar to 70-nm region with a peak transmission at 270 nm. Quantitative radial NO profiles obtained by LSF are presented and analyzed so as to correct similar LIF and PLIF profiles. Excellent agreement is achieved among the three fluorescence methodologies. (C) 1998 Optical Society of America.
引用
收藏
页码:4823 / 4833
页数:11
相关论文
共 50 条
  • [1] Laser-induced fluorescence measurements in lean direct-injection spray flames: technique development and application
    Cooper, CS
    Laurendeau, NM
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (07) : 902 - 911
  • [2] Comparison of laser-induced and planar laser-induced fluorescence measurements of nitric oxide in a high-pressure, swirl-stabilized, spray flame
    Cooper, CS
    Laurendeau, NM
    APPLIED PHYSICS B-LASERS AND OPTICS, 2000, 70 (06): : 903 - 910
  • [3] Comparison of laser-induced and planar laser-induced fluorescence measurements of nitric oxide in a high-pressure, swirl-stabilized, spray flame
    C.S. Cooper
    N.M. Laurendeau
    Applied Physics B, 2000, 70 : 903 - 910
  • [4] Quantitative laser-saturated fluorescence measurements of nitric oxide in a heptane-fueled lean direct-injection spray flame at varying global equivalence ratios
    Cooper, CS
    Laurendeau, NM
    TWENTY-SEVENTH SYMPOSIUM (INTERNATIONAL) ON COMBUSTION, VOLS 1 AND 2, 1998, : 1993 - 2000
  • [5] Quantitative laser-saturated fluorescence measurements of nitric oxide in a heptane spray flame
    Cooper, CS
    Laurendeau, NM
    COMBUSTION SCIENCE AND TECHNOLOGY, 1997, 127 (1-6) : 363 - &
  • [6] Temperature measurements in a Bunsen flame by planar laser-induced fluorescence
    Tolstoguzov, R., V
    XXXVI SIBERIAN THERMOPHYSICAL SEMINAR (STS 36), 2020, 1677
  • [7] Laser-induced fluorescence of seeded nitric oxide as a flame thermometer
    SRI Int, Menlo Park, United States
    Appl Phys B, 4 (503-510):
  • [8] Laser-induced fluorescence of seeded nitric oxide as a flame thermometer
    M. Tamura
    J. Luque
    J.E. Harrington
    P.A. Berg
    G.P. Smith
    J.B. Jeffries
    D.R. Crosley
    Applied Physics B, 1998, 66 : 503 - 510
  • [9] Laser-induced fluorescence of seeded nitric oxide as a flame thermometer
    Tamura, M
    Luque, J
    Harrington, JE
    Berg, PA
    Smith, GP
    Jeffries, JB
    Crosley, DR
    APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 66 (04): : 503 - 510
  • [10] Laser-saturated fluorescence measurements of nitric oxide in an inverse diffusion flame
    Partridge, WP
    Reisel, JR
    Laurendeau, NM
    COMBUSTION AND FLAME, 1999, 116 (1-2) : 282 - 290