Robust modeling for multivariate calibration transfer by the successive projections algorithm

被引:56
作者
Honorato, FA
Galvao, RKH
Pimentel, MF
Neto, BD
Araújo, MCU
de Carvalho, FR
机构
[1] Univ Fed Pernambuco, Dept Engn Quim, Cidade Univ, BR-50740521 Recife, PE, Brazil
[2] Univ Fed Pernambuco, Dept Quim Fundamental, Recife, PE, Brazil
[3] Univ Fed Pernambuco, Dept Quim Fundamental, Recife, PE, Brazil
关键词
multivariate calibration transfer; robust modeling; successive projections algorithm; FT-IR spectrometry; Piecewise Direct Standardization; Kennard-Stone algorithm;
D O I
10.1016/j.chemolab.2004.09.006
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The use of the Successive Projections Algorithm (VSPA) to select variables for building robust transferable Multiple Linear Regression (MLR) models is investigated. The robustness requirement is explicitly taken into account by introducing some spectra acquired by the slave instrument in the validation set that guides VSPA selection. The transfer samples are selected by the classic Kennard-Stone (KS) algorithm or a modified version of VSPA (SSPA) that operates across the rows of the instrumental response matrix, instead of the columns. The proposed approach was tested in two data sets, each set consisting of spectra obtained by infrared spectrometry in two different instruments. The first data set consists of gasoline spectra, which are employed to predict the distillation temperature at which 90% of the sample has evaporated (T 90%). The second data set consists of corn spectra, which are employed for moisture determination. The robust MLR models were compared to a PLS model employing Piecewise Direct Standardization (PDS) to correct the slave spectra. In both data sets, the mean prediction errors at the slave instrument for the robust VSPA-MLR and the PLS-PDS models were comparable, and slightly better for VSPA-MLR. The proposed approach appears to be a valid alternative to the commonly used PLS-PDS technique. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 22 条
[1]   Transfer by orthogonal projection: making near-infrared calibrations robust to between-instrument variation [J].
Andrew, A ;
Fearn, T .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 72 (01) :51-56
[2]  
[Anonymous], CHEMOMETR INTELL LAB, DOI DOI 10.1016/S0169-7439(02)00085-0
[3]   The successive projections algorithm for variable selection in spectroscopic multicomponent analysis [J].
Araújo, MCU ;
Saldanha, TCB ;
Galvao, RKH ;
Yoneyama, T ;
Chame, HC ;
Visani, V .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2001, 57 (02) :65-73
[4]  
*ASTM, 2000, D86 ASTM
[5]   Standardization of near-infrared spectrometric instruments [J].
Bouveresse, E ;
Hartmann, C ;
Massart, DL ;
Last, IR ;
Prebble, KA .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :982-990
[6]   Determination of total sulfur in diesel fuel employing NIR spectroscopy and multivariate calibration [J].
Breitkreitz, MC ;
Raimundo, IM ;
Rohwedder, JJR ;
Pasquini, C ;
Dantas, HA ;
José, GE ;
Araújo, MCU .
ANALYST, 2003, 128 (09) :1204-1207
[7]  
*CAMO ASA NEDR VOL, UNSCR 7 6
[8]   A solution to the wavelet transform optimization problem in multicomponent analysis [J].
Coelho, CJ ;
Galvao, RKH ;
Araujo, MCU ;
Pimentel, MF ;
da Silva, EC .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 66 (02) :205-217
[9]   A linear semi-infinite programming strategy for constructing optimal wavelet transforms in multivariate calibration problems [J].
Coelho, CJ ;
Galvao, RKH ;
de Araújo, MCU ;
Pimentel, MF ;
da Silva, EC .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 2003, 43 (03) :928-933
[10]   A strategy for selecting calibration samples for multivariate modelling [J].
Dantas, HA ;
Galvao, RKH ;
Araújo, MCU ;
da Silva, EC ;
Saldanha, TCB ;
José, GE ;
Pasquini, C ;
Raimundo, IM ;
Rohwedder, JJR .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 72 (01) :83-91