Mass transfer and chemical reaction in hollow-fiber membrane reactors

被引:9
|
作者
Li, K [1 ]
Tan, XY
机构
[1] Univ Bath, Dept Chem Engn, Bath BA2 7AY, Avon, England
[2] Shandong Inst Technol, Dept Chem Engn, Shandong 255012, Peoples R China
关键词
D O I
10.1002/aic.690470219
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Theoretical models developed describe hollow-fiber memebrane reactors (modules), in which membrane functions as an efficient reactant distributor and the chemical reaction takes place either in the hollow-fiber lumen or in the shell side. Effects of various design and operating parameters, and physical properties on the performance of the reactors were studied. Simulation results indicated that the axial dispersion has to be considered when the chemical reaction takes place in the shell side. It, however, may be neglected when Pe > 40. Theoretical results further revealed that the mass-transfer direction of the reactant through the membrane might be reversed when the chemical reaction in the liquid is extremely fast. Experimental data in the literature obtained from water-treatment processes agreed satisfactorily with the theoretical solutions. Based on the developed solution method, the reaction kinetic parameters can also be obtained conveniently.
引用
收藏
页码:427 / 435
页数:9
相关论文
共 50 条
  • [1] Simulation of external mass transfer in hollow-fiber membrane contactors
    V. A. Kirsch
    V. I. Roldugin
    S. D. Bazhenov
    T. V. Plisko
    Petroleum Chemistry, 2015, 55 : 776 - 782
  • [2] Simulation of external mass transfer in hollow-fiber membrane contactors
    Kirsch, V. A.
    Roldugin, V. I.
    Bazhenov, S. D.
    Plisko, T. V.
    PETROLEUM CHEMISTRY, 2015, 55 (10) : 776 - 782
  • [3] Preparation of coiled hollow-fiber membrane and mass transfer performance in membrane extraction
    Liu, SH
    Luo, GS
    Wang, Y
    Wang, YJ
    JOURNAL OF MEMBRANE SCIENCE, 2003, 215 (1-2) : 203 - 211
  • [4] Mass transfer simulation of solvent extraction in hollow-fiber membrane contactors
    Fadaei, Farzad
    Shirazian, Saeed
    Ashrafizadeh, Seyed Nezameddin
    DESALINATION, 2011, 275 (1-3) : 126 - 132
  • [5] A study of mass transfer in hollow-fiber membrane contactors - The effect of fiber packing fraction
    Asimakopoulou, A. G.
    Karabelas, A. J.
    JOURNAL OF MEMBRANE SCIENCE, 2006, 282 (1-2) : 430 - 441
  • [6] Analysis of mass transfer in hollow-fiber membranes
    Nagy, E
    Hadik, P
    DESALINATION, 2002, 145 (1-3) : 147 - 152
  • [7] MICROPOROUS HOLLOW-FIBER MEMBRANE MODULES AS GAS-LIQUID CONTACTORS .2. MASS-TRANSFER WITH CHEMICAL-REACTION
    KREULEN, H
    SMOLDERS, CA
    VERSTEEG, GF
    VANSWAAIJ, WPM
    JOURNAL OF MEMBRANE SCIENCE, 1993, 78 (03) : 217 - 238
  • [8] Lumen mass transfer in hollow-fiber membrane processes with nonlinear boundary conditions
    Qin, YJ
    Cabral, JMS
    AICHE JOURNAL, 1998, 44 (04) : 836 - 848
  • [9] Lumen mass transfer in hollow-fiber membrane processes with constant external resistances
    Qin, YJ
    Cabral, JMS
    AICHE JOURNAL, 1997, 43 (08) : 1975 - 1988
  • [10] Modeling Ionic Strength Effects on Hollow-Fiber Nanofiltration Membrane Mass Transfer
    Yonge, David T.
    Biscardi, Paul G.
    Duranceau, Steven J.
    MEMBRANES, 2018, 8 (03)