Titanium Particle Exfoliation from Different Dental Implants after Insertion

被引:0
|
作者
Vijintanawan, Sakanus [1 ]
Boonsiriseth, Kiatanant [1 ]
Bhattarai, Bishwa Prakash [2 ]
Suphangul, Suphachai [3 ]
Pairuchvej, Verasak [1 ]
Wongsirichat, Natthamet [2 ]
机构
[1] Mahidol Univ, Fac Dent, Dept Oral Maxillofacial Surg, 6 Yothi St, Bangkok 10400, Thailand
[2] Walailak Univ, Int Coll Dent, 979-42-46 Phahonyothin Rd,19th Floor SM Tower, Bangkok 10400, Thailand
[3] Mahidol Univ, Fac Dent, Dept Adv Gen Dent, 6 Yothi St, Bangkok 10400, Thailand
来源
ARCHIVES OF OROFACIAL SCIENCE | 2020年 / 15卷 / 02期
关键词
Dental implant; post insertion; surface damage; titanium exfoliation; titanium particle; MARGINAL BONE LOSS; IN-VITRO; NANOPARTICLES; BIOCORROSION; DETACHMENT; SURFACES; ABUTMENT; RELEASE; TORQUE; MICE;
D O I
10.21315/aos2020.15.2.448
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The titanium exfoliation level during dental implant installation has not yet been available. The present study aims to confirm the presence of titanium exfoliation in different implant surfaces throughout the installation and identify the association between insertion torque and surface abrasion. Three different implant surfaces were assigned to low and high insertion torque groups. The implants were installed into porcine bone blocks. Then, the surrounding bone at the ostomy site was analysed for the titanium exfoliation using an inductively coupled plasma mass spectrometry. The low and high insertion torques were 30 Ncm and 58 Ncm, respectively. The average titanium content from all samples was 4.9 +/- 2.7 mu g. Anodised implant released significantly less titanium compared to others (p < 0.05). All implants released titanium indifferently compared to low and high insertion torques (p > 0.05). Within the limitation of the present study, anodised implant released the least amount of titanium exfoliation. The insertion torque was not associated with titanium exfoliation.
引用
收藏
页码:149 / 158
页数:10
相关论文
共 50 条
  • [21] A study of different calcification areas in newly formed bone 8 weeks after insertion of dental implants in rabbit tibias
    Konig, B
    Beck, TJ
    Kappert, HF
    Kappert, CC
    Masuko, TS
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 1998, 180 (05) : 471 - 475
  • [22] The Mechanisms of Degradation of Titanium Dental Implants
    Ossowska, Agnieszka
    Zielinski, Andrzej
    COATINGS, 2020, 10 (09)
  • [23] STRUCTURE AND PROPERTIES OF TITANIUM FOR DENTAL IMPLANTS
    Greger, Miroslav
    Kander, Ladislav
    Masek, Vaclav
    NANOCON 2011, 2011, : 594 - 600
  • [24] STRUCTURE AND PROPERTIES OF TITANIUM FOR DENTAL IMPLANTS
    Greger, M.
    Cerny, M.
    Kander, L.
    Kliber, J.
    METALURGIJA, 2009, 48 (04): : 249 - 252
  • [25] Application of PM titanium for dental implants
    不详
    POWDER METALLURGY, 2003, 46 (04) : 299 - 300
  • [26] Assessing the roughness of titanium dental implants
    Monetta, T.
    Marchesano, G.
    Bellucci, F.
    Lupo, G.
    Itro, A.
    DENTAL CADMOS, 2014, 82 (07) : 498 - 508
  • [27] Titanium Alloys for Dental Implants: A Review
    Nicholson, John W.
    PROSTHESIS, 2020, 2 (02): : 100 - 116
  • [28] Titanium Corrosion: Implications For Dental Implants
    Shah, Rucha
    Penmetsa, Deepika Shree Lakshmi
    Thomas, Raison
    Mehta, Dhoom Singh
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2016, 24 (04): : 171 - 180
  • [29] TITANIUM DEPOSITION IN REGIONAL LYMPH-NODES AFTER INSERTION OF TITANIUM SCREW IMPLANTS IN MAXILLOFACIAL REGION
    WEINGART, D
    STEINEMANN, S
    SCHILLI, W
    STRUB, JR
    HELLERICH, U
    ASSENMACHER, J
    SIMPSON, J
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 23 (06) : 450 - 452
  • [30] The Effects of Insertion Approach on the Stability of Dental Implants
    Hsu, Yuan-Yang
    Huang, Heng-Li
    Fuh, Lih-Jyh
    Tsai, Ming-Tzu
    Hsu, Jui-Ting
    APPLIED BIONICS AND BIOMECHANICS, 2022, 2022