A glucose biosensor using methyl viologen redox mediator on carbon film electrodes

被引:88
作者
Ghica, ME [1 ]
Brett, CMA [1 ]
机构
[1] Univ Coimbra, Dept Quim, P-3004535 Coimbra, Portugal
关键词
glucose; glucose oxidase; amperometric enzyme electrode; carbon film electrode; methyl viologen mediator; Nafion;
D O I
10.1016/j.aca.2004.10.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new methyl viologen-mediated amperometric enzyme electrode sensitive to glucose has been developed using carbon film electrode substrates. Carbon film electrodes from resistors fabricated by pyrolytic deposition of carbon were modified by immobilization of glucose oxidase through cross-linking with glutaraldehyde in the presence of bovine serum albumin. The mediator, methyl viologen, was directly immobilised with the enzyme together with Nafion cation-exchange polymer. The electrochemistry of the glucose oxidase/methyl viologen modified electrode was investigated by cyclic voltammetry and by electrochemical impedance spectroscopy. The biosensor response to glucose was evaluated amperometrically; the detection limit was 20 mu M, the linear range extended to 1.2 mM and the reproducibility of around 3 When stored in phosphate buffer at 4 degrees C and used every day, the sensor showed good stability over more several weeks. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 33 条
  • [1] AMPEROMETRIC ENZYME ELECTRODES .1. THEORY
    ALBERY, WJ
    BARTLETT, PN
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02): : 211 - 222
  • [2] Electrochemical behavior of methyl viologen at graphite electrodes modified with Nafion sol-gel composite
    Barroso-Fernandez, B
    Lee-Alvarez, MT
    Seliskar, CJ
    Heineman, WR
    [J]. ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) : 221 - 230
  • [3] Brett CMA, 2001, ELECTROANAL, V13, P765, DOI 10.1002/1521-4109(200105)13:8/9<765::AID-ELAN765>3.0.CO
  • [4] 2-3
  • [5] FERRICINIUM ION AS AN ELECTRON-ACCEPTOR FOR OXIDO-REDUCTASES
    CASS, AEG
    DAVIS, G
    GREEN, MJ
    HILL, HAO
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 190 (1-2): : 117 - 127
  • [6] Mediated biosensors
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) : 441 - 456
  • [7] Development of biosensors based on hexacyanoferrates
    de Mattos, IL
    Gorton, L
    Laurell, T
    Malinauskas, A
    Karyakin, AA
    [J]. TALANTA, 2000, 52 (05) : 791 - 799
  • [8] Metal hexacyanoferrates: Electrosynthesis, in situ characterization, and applications
    de Tacconi, NR
    Rajeshwar, K
    Lezna, RO
    [J]. CHEMISTRY OF MATERIALS, 2003, 15 (16) : 3046 - 3062
  • [9] DETERMINATION OF THE REACTIVE AREA OF ORGANIC COATED METALS - PHYSICAL MEANING AND LIMITS OF THE BREAK-POINT METHOD
    DEFLORIAN, F
    FEDRIZZI, L
    BONORA, PL
    [J]. ELECTROCHIMICA ACTA, 1993, 38 (12) : 1609 - 1613
  • [10] AMPEROMETRIC ENZYME ELECTRODE FOR NADP(+) BASED ON A FERRODOXIN-NADP(+) REDUCTASE AND VIOLOGEN-MODIFIED GLASSY-CARBON ELECTRODE
    DELACEY, AL
    BES, MT
    GOMEZMORENO, C
    FERNANDEZ, VM
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 390 (1-2): : 69 - 76