Improved calibration method for lateral force of the cantilever deflection force sensor in atomic force microscope

被引:1
|
作者
Wang, Fei [1 ]
Zhao, Xuezeng [1 ]
机构
[1] Harbin Inst Technol, Sch Mech & Elect Engn, Harbin, Peoples R China
关键词
calibration; candlever; atomic force microscope;
D O I
10.1109/NEMS.2006.334616
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Quantitative friction measurement of nano materials in atomic force microscope (AFM) requires accurate calibration method for the lateral force. An improved calibration method for the lateral force of the cantilever in AFM is presented. The calibration factor derived from the original method increased with the applied normal load, which indicates that separate calibration should be required for every given applied normal load to keep the accuracy of friction measurement. We analyze the reason for this phenomenon, and improve the original method by introducing the contact factor, which is derived from the contact stiffness between the tip and the sample, to the calculation of calibration factors. Our method makes the calculation of calibration factors under different applied normal loads be possible without repeating the calibration procedure. Comparative experiments on a silicon wafer have been done by both the two methods to validate our method..
引用
收藏
页码:34 / 37
页数:4
相关论文
共 50 条
  • [31] Improved atomic force microscope
    Eroshenko, Yu N.
    PHYSICS-USPEKHI, 2009, 52 (10) : 1081 - 1081
  • [32] Experimental Research of Improved Sensor of Atomic Force Microscope
    Bucinskas, Vytautas
    Dzedzickis, Andrius
    Sutinys, Ernestas
    Sesok, Nikolaj
    Iljin, Igor
    RECENT ADVANCES IN SYSTEMS, CONTROL AND INFORMATION TECHNOLOGY, 2017, 543 : 601 - 609
  • [33] Cantilever contribution to the total electrostatic force measured with the atomic force microscope
    Guriyanova, Svetlana
    Golovko, Dmytro S.
    Bonaccurso, Elmar
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (02)
  • [34] METHOD FOR THE CALIBRATION OF ATOMIC-FORCE MICROSCOPE CANTILEVERS
    SADER, JE
    LARSON, I
    MULVANEY, P
    WHITE, LR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (07): : 3789 - 3798
  • [35] Improved lateral force calibration based on the angle conversion factor in atomic force microscopy
    Choi, Dukhyun
    Hwang, Woonbong
    Yoon, Euisung
    JOURNAL OF MICROSCOPY, 2007, 228 (02) : 190 - 199
  • [36] SCANNED-CANTILEVER ATOMIC FORCE MICROSCOPE
    BASELT, DR
    BALDESCHWIELER, JD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (04): : 908 - 911
  • [37] MICROFABRICATION OF CANTILEVER STYLI FOR THE ATOMIC FORCE MICROSCOPE
    ALBRECHT, TR
    AKAMINE, S
    CARVER, TE
    QUATE, CF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (04): : 3386 - 3396
  • [38] Lateral force separation of biopolymers using an atomic force microscope
    Anderson, Mark S.
    BIOMICROFLUIDICS, 2023, 17 (03)
  • [39] Design of Cantilever Accessory for Atomic Force Microscope
    Katou, Seiya
    Nakakuki, Takashi
    2012 12TH IEEE CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2012,
  • [40] Improved atomic force microscope cantilever performance by ion beam modification
    Hodges, AR
    Bussmann, KM
    Hoh, JH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (10): : 3880 - 3883