Characterization of a double probe for local pulse wave velocity assessment

被引:13
|
作者
Pereira, H. Catarina [1 ,2 ]
Pereira, Tania [1 ]
Almeida, Vania [1 ]
Borges, Elisabeth [1 ]
Figueiras, Edite [1 ]
Simoes, J. Basilio [1 ,2 ]
Malaquias, J. Luis [2 ]
Cardoso, Joao M. R. [1 ]
Correia, Carlos M. B. [1 ]
机构
[1] Univ Coimbra, Instrumentat Ctr, Elect & Instrumentat Grp, Coimbra, Portugal
[2] ISA, Coimbra, Portugal
关键词
haemodynamics; local pulse-wave velocity; double piezoelectric probe; test bench; impulse response; EXPERT CONSENSUS DOCUMENT; CAROTID-ARTERY; STIFFNESS; PRESSURE; ALGORITHM; SENSOR;
D O I
10.1088/0967-3334/31/11/004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Local pulse-wave velocity (PWV) is an accurate indicator of the degree of arteriosclerosis (stiffness) in an artery, providing a direct characterization of the properties of its wall. Devices currently available for local PWV measurement are mainly based on ultrasound systems and have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. The present work describes a new type of probe, based on a double-headed piezoelectric (PZ) sensor. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both PZs, placed 23 mm apart. The double probe (DP) characterization is accomplished in three main studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system. The first study refers to determination of the impulse response (IR) for each PZ sensor, whereas the second one explores the existence of crosstalk between both transducers. In the last one, DP time resolution is inferred from a set of three different algorithms based on (a) the maximum of cross-correlation function, (b) the maximum amplitude detection and (c) the zero-crossing point identification. These values were compared with those obtained by the reference method, which consists of the simultaneous acquisition of pressure waves by means of two pressure sensors. The new probe demonstrates good performance on the test bench system and results show that the signals do not exhibit crosstalk. A good agreement was also verified between the PWV obtained from the DP signals (19.55 +/- 2.02 ms(-1)) and the PWV determined using the reference method (19.26 +/- 0.04 ms(-1)). Although additional studies are still required, this probe seems to be a valid alternative to local PWV stand-alone devices.
引用
收藏
页码:1449 / 1465
页数:17
相关论文
共 50 条
  • [41] A NEW APPROACH FOR ASSESSMENT OF PULSE WAVE VELOCITY AT RADIAL ARTERY IN YOUNG AND MIDDLE-AGED HEALTHY HUMANS
    Zhang, Yong-Liang
    Ma, Zu-Chang
    Lung, Chi-Wen
    Sun, Yi-Ning
    Li, Xin-Hui
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2012, 12 (05)
  • [42] Local Arterial Stiffness Assessment: Comparison of Pulse Wave Velocity Assessed by Ultrafast Ultrasound Imaging versus the Bramwell-Hill Equation
    Rasouli, Rahna
    Baranger, Jerome
    Slorach, Cameron
    Minh Nguyen
    Segers, Patrick
    Guerra, Vitor
    Pernot, Mathieu
    Hui, Wei
    Mertens, Luc
    Villemain, Olivier
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2022, 35 (11) : 1185 - +
  • [43] Measurement of Aortic Pulse Wave Velocity With a Connected Bathroom Scale
    Campo, David
    Khettab, Hakim
    Yu, Roger
    Genain, Nicolas
    Edouard, Paul
    Buard, Nadine
    Boutouyrie, Pierre
    AMERICAN JOURNAL OF HYPERTENSION, 2017, 30 (09) : 876 - 883
  • [44] COMPARISON OF DIFFERENT PULSE WAVEFORMS FOR LOCAL PULSE WAVE VELOCITY MEASUREMENT IN HEALTHYAND HYPERTENSIVE COMMON CAROTID ARTERIES IN VIVO
    Huang, Chengwu
    Su, Yuan
    Zhang, Hong
    Qian, Lin-Xue
    Luo, Jianwen
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (05) : 1111 - 1123
  • [45] Numerical assessment and comparison of pulse wave velocity methods aiming at measuring aortic stiffness
    Obeid, Hasan
    Soulat, Gilles
    Mousseaux, Elie
    Laurent, Stephane
    Stergiopulos, Nikos
    Boutouyrie, Pierre
    Segers, Patrick
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (11) : 1953 - 1967
  • [46] Non-invasive assessment of pulse wave velocity in mice by means of ultrasound images
    Di Lascio, Nicole
    Stea, Francesco
    Kusmic, Claudia
    Sicari, Rosa
    Faita, Francesco
    ATHEROSCLEROSIS, 2014, 237 (01) : 31 - 37
  • [47] A modelling framework for assessment of arterial compliance by fusion of oscillometry and pulse wave velocity information
    Bogatu, Laura, I
    Turco, Simona
    Mischi, Massimo
    Woerlee, Pierre
    Bouwman, Arthur
    Korsten, Erik H. H. M.
    Muehlsteff, Jens
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 196
  • [48] A method for determining local pulse wave velocity in human ascending aorta from sequential ultrasound measurements of diameter and velocity
    Negoita, Madalina
    Hughes, Alun D.
    Parker, Kim H.
    Khir, Ashraf W.
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (11)
  • [49] Measurement of local pulse wave velocity for carotid artery by using an ultrasound-based method
    Tang, Chieh-Ju
    Lee, Po-Yang
    Chuang, Yi-Hsiang
    Huang, Chih-Chung
    ULTRASONICS, 2020, 102
  • [50] Estimation of local pulse wave velocity using arterial diameter waveforms: Experimental validation in sheep
    Graf, S.
    Craiem, D.
    Barra, J. G.
    Armentano, R. L.
    8TH ARGENTINEAN BIOENGINEERING SOCIETY CONFERENCE (SABI 2011) AND 7TH CLINICAL ENGINEERING MEETING, 2011, 332