Characterization of a double probe for local pulse wave velocity assessment

被引:13
|
作者
Pereira, H. Catarina [1 ,2 ]
Pereira, Tania [1 ]
Almeida, Vania [1 ]
Borges, Elisabeth [1 ]
Figueiras, Edite [1 ]
Simoes, J. Basilio [1 ,2 ]
Malaquias, J. Luis [2 ]
Cardoso, Joao M. R. [1 ]
Correia, Carlos M. B. [1 ]
机构
[1] Univ Coimbra, Instrumentat Ctr, Elect & Instrumentat Grp, Coimbra, Portugal
[2] ISA, Coimbra, Portugal
关键词
haemodynamics; local pulse-wave velocity; double piezoelectric probe; test bench; impulse response; EXPERT CONSENSUS DOCUMENT; CAROTID-ARTERY; STIFFNESS; PRESSURE; ALGORITHM; SENSOR;
D O I
10.1088/0967-3334/31/11/004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Local pulse-wave velocity (PWV) is an accurate indicator of the degree of arteriosclerosis (stiffness) in an artery, providing a direct characterization of the properties of its wall. Devices currently available for local PWV measurement are mainly based on ultrasound systems and have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. The present work describes a new type of probe, based on a double-headed piezoelectric (PZ) sensor. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both PZs, placed 23 mm apart. The double probe (DP) characterization is accomplished in three main studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system. The first study refers to determination of the impulse response (IR) for each PZ sensor, whereas the second one explores the existence of crosstalk between both transducers. In the last one, DP time resolution is inferred from a set of three different algorithms based on (a) the maximum of cross-correlation function, (b) the maximum amplitude detection and (c) the zero-crossing point identification. These values were compared with those obtained by the reference method, which consists of the simultaneous acquisition of pressure waves by means of two pressure sensors. The new probe demonstrates good performance on the test bench system and results show that the signals do not exhibit crosstalk. A good agreement was also verified between the PWV obtained from the DP signals (19.55 +/- 2.02 ms(-1)) and the PWV determined using the reference method (19.26 +/- 0.04 ms(-1)). Although additional studies are still required, this probe seems to be a valid alternative to local PWV stand-alone devices.
引用
收藏
页码:1449 / 1465
页数:17
相关论文
共 50 条
  • [11] Non-Invasive Assessment of Local Pulse Wave Velocity as Function of Arterial Pressure
    Nabeel, P. M.
    Kiran, Raj, V
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 672 - 677
  • [12] Local Pulse Wave Velocity: Theory, Methods, Advancements, and Clinical Applications
    Nabeel, P. M.
    Kiran, V. Raj
    Joseph, Jayaraj
    Abhidev, V. V.
    Sivaprakasam, Mohanasankar
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2020, 13 : 74 - 112
  • [13] Advancing the Local Pulse Wave Velocity Measurement-Wave Confluence Decomposition Using a Double Gaussian Propagation Model
    Beutel, Fabian
    Van Hoof, Chris
    Hermeling, Evelien
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (08) : 2495 - 2505
  • [14] Assessment of local pulse wave velocity in arteries using 2D distension waveforms
    Meinders, JM
    Kornet, L
    Brands, PJ
    Hoeks, APG
    ULTRASONIC IMAGING, 2001, 23 (04) : 199 - 215
  • [15] P.03 Local Pulse Wave Velocity Estimation using a Double Gaussian Propagation Model
    Fabian Beutel
    Chris Van Hoof
    Evelien Hermeling
    Artery Research, 2020, 26 (Suppl 1) : S23 - S23
  • [16] Assessment of Model Based (Input) Impedance, Pulse Wave Velocity, and Wave Reflection in the Asklepios Cohort
    Hametner, Bernhard
    Parragh, Stephanie
    Mayer, Christopher
    Weber, Thomas
    Luc Van Bortel
    De Buyzere, Marc
    Segers, Patrick
    Rietzschel, Ernst
    Wassertheurer, Siegfried
    PLOS ONE, 2015, 10 (10):
  • [17] A Flexible Ultrasound Array for Local Pulse Wave Velocity Monitoring
    Xu, Lirui
    Wang, Peng
    Xia, Pan
    Wu, Pang
    Chen, Xianxiang
    Du, Lidong
    Liu, Jiexin
    Xue, Ning
    Fang, Zhen
    BIOSENSORS-BASEL, 2022, 12 (07):
  • [18] Phantom Assessment of an Image-free Ultrasound Technology for Online Local Pulse Wave Velocity Measurement
    Kiran, Raj, V
    Nabeel, P. M.
    Manoj, Rahul
    Shah, Malay Ilesh
    Sivaprakasam, Mohanasankar
    Joseph, Jayaraj
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5610 - 5613
  • [19] Estimation of central pulse wave velocity from radial pulse wave analysis
    Yao, Yang
    Zhou, Shuran
    Alastruey, Jordi
    Hao, Liling
    Greenwald, Stephen E.
    Zhang, Yuelan
    Xu, Lin
    Xu, Lisheng
    Yao, Yudong
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 219
  • [20] Comprehensive assessment of coronary pulse wave velocity in anesthetized pigs
    Cividjian, Andrei
    Harbaoui, Brahim
    Chambonnet, Carole
    Bonnet, Jeanne-Marie
    Paquet, Christian
    Courand, Pierre-Yves
    Lantelme, Pierre
    PHYSIOLOGICAL REPORTS, 2020, 8 (09):