Characterization of a double probe for local pulse wave velocity assessment

被引:13
|
作者
Pereira, H. Catarina [1 ,2 ]
Pereira, Tania [1 ]
Almeida, Vania [1 ]
Borges, Elisabeth [1 ]
Figueiras, Edite [1 ]
Simoes, J. Basilio [1 ,2 ]
Malaquias, J. Luis [2 ]
Cardoso, Joao M. R. [1 ]
Correia, Carlos M. B. [1 ]
机构
[1] Univ Coimbra, Instrumentat Ctr, Elect & Instrumentat Grp, Coimbra, Portugal
[2] ISA, Coimbra, Portugal
关键词
haemodynamics; local pulse-wave velocity; double piezoelectric probe; test bench; impulse response; EXPERT CONSENSUS DOCUMENT; CAROTID-ARTERY; STIFFNESS; PRESSURE; ALGORITHM; SENSOR;
D O I
10.1088/0967-3334/31/11/004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Local pulse-wave velocity (PWV) is an accurate indicator of the degree of arteriosclerosis (stiffness) in an artery, providing a direct characterization of the properties of its wall. Devices currently available for local PWV measurement are mainly based on ultrasound systems and have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. The present work describes a new type of probe, based on a double-headed piezoelectric (PZ) sensor. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both PZs, placed 23 mm apart. The double probe (DP) characterization is accomplished in three main studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system. The first study refers to determination of the impulse response (IR) for each PZ sensor, whereas the second one explores the existence of crosstalk between both transducers. In the last one, DP time resolution is inferred from a set of three different algorithms based on (a) the maximum of cross-correlation function, (b) the maximum amplitude detection and (c) the zero-crossing point identification. These values were compared with those obtained by the reference method, which consists of the simultaneous acquisition of pressure waves by means of two pressure sensors. The new probe demonstrates good performance on the test bench system and results show that the signals do not exhibit crosstalk. A good agreement was also verified between the PWV obtained from the DP signals (19.55 +/- 2.02 ms(-1)) and the PWV determined using the reference method (19.26 +/- 0.04 ms(-1)). Although additional studies are still required, this probe seems to be a valid alternative to local PWV stand-alone devices.
引用
收藏
页码:1449 / 1465
页数:17
相关论文
共 50 条
  • [1] DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION A New Device for Hemodynamic Parameters Assessment
    Pereira, H. C.
    Simoes, J. B.
    Malaquias, J. L.
    Pereira, T.
    Almeida, V.
    Borges, E.
    Figueiras, E.
    Cardoso, J.
    Correia, C.
    BIODEVICES 2011, 2011, : 444 - +
  • [2] Double Probe Based in Piezoelectric Sensors for Local Pulse Wave Velocity Assessment
    Pereira Lopes, Tania Maria
    Correia, Carlos
    2012 IEEE 2ND PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2012,
  • [3] Methodological and Measurement Concerns of Local Pulse Wave Velocity Assessment
    Kiran, Raj, V
    Nabeel, P. M.
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2019 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2019,
  • [4] A Magnetic Plethysmograph Probe for Local Pulse Wave Velocity Measurement
    Nabeel, P. M.
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (05) : 1065 - 1076
  • [5] OPTICAL METHODS FOR LOCAL PULSE WAVE VELOCITY ASSESSMENT
    Pereira, T.
    Cabeleira, M.
    Matos, P.
    Borges, E.
    Almeida, V.
    Cardoso, J.
    Correia, C.
    Pereira, H. C.
    BIOSIGNALS 2011, 2011, : 74 - 81
  • [6] Experimental Validation of Dual PPG Local Pulse Wave Velocity Probe
    Nabeel, P. M.
    Karthik, Srinivasa
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2017 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2017, : 408 - 413
  • [7] Arterial compliance probe for local blood pulse wave velocity measurement
    Nabeel, P. M.
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5712 - 5715
  • [8] Assessment of pulse wave velocity
    Boutouyrie P.
    Briet M.
    Collin C.
    Vermeersch S.
    Pannier B.
    Artery Research, 2009, 3 (1) : 3 - 8
  • [9] Pulse Wave Analysis and Pulse Wave Velocity for Fistula Assessment
    Mueller, Niklas
    Streis, Joachim
    Mueller, Sandra
    Pavenstaedt, Hermann
    Felderhoff, Thomas
    Reuter, Stefan
    Busch, Veit
    KIDNEY & BLOOD PRESSURE RESEARCH, 2020, 45 (04) : 576 - 588
  • [10] Distance measurements for the assessment of carotid to femoral pulse wave velocity
    Vermeersch, Sebastian J.
    Rietzschel, Ernst R.
    De Buyzere, Marc L.
    Van Bortel, Luc M.
    Gillebert, Thierry C.
    Verdonck, Pascal R.
    Laurent, Stephane
    Segers, Patrick
    Boutouyrie, Pierre
    JOURNAL OF HYPERTENSION, 2009, 27 (12) : 2377 - U2