COMPARISON OF CYSTATIN-C-BASED FORMULAS FOR EVALUATION OF RESIDUAL RENAL FUNCTION IN PERITONEAL DIALYSIS PATIENTS

被引:0
作者
Zhang, Suojian [1 ]
Zhang, Xu [1 ]
Li, Haitao [1 ]
Cao, Juan [1 ]
机构
[1] Taixing Peoples Hosp, Dept Nephrol, Taizhou 225400, Peoples R China
来源
ACTA MEDICA MEDITERRANEA | 2021年 / 37卷 / 04期
关键词
peritoneal dialysis; cystatin C; residual renal function; formula; GLOMERULAR-FILTRATION-RATE; SERUM CREATININE; CLEARANCE; MARKER; HEMODIALYSIS; MORTALITY; DECLINE;
D O I
10.19193/0393-6384_2021_4_303
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The present study aims to compare three cystatin-C (cys C)-based formulas which evaluate residual renal function (RRF) in peritoneal dialysis (PD) patients. Materials and methods: 94 patients who were undergoing regular PD treatment were enrolled. The average clearance of 24-h urea and creatinine was taken as the gold standard, which was called measured RRF (mRRF). RRF was also estimated by the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI), Hoek and Yang formulas, We compared the deviation and accuracy of estimated RRF (eRRF) calculated by the three formulas. Results: CysC was not correlated with demographic characteristics, albumin, prealbumin, blood glucose, glycosylated hemoglobin, intact parathyroid hormone or high-sensitivity C-reactive protein, and negatively correlated with mRRF. The mean) bias and limit of agreement were -3.9 (-0.7 to -7.1) ml/min/1.73 m2 for the CKD-EPI formula, -0.3 (2.6 to -3.2) ml/min/1.73 m2 for the Hoek formula and 0.9 (3.6 to -1.9)ml/min/1.73 m2 for the Yang formula. The Yang formula showed the smallest relative difference and. inaccuracy between CKD-EPI showed the largest. Accuracy of the CKD-EPI formula was the worst and there was no difference between the Hoek and Yang formulas within 30% and 50%. Conclusion: The CKD-EPI formula showed the largest bias and the lowest accuracy. The Hoek formula showed the smallest mean bias and the Yang formula had the smallest relative differences. There was no difference between the Yang and Hoek formulas for accuracy within 30% and 50%. It may inappropriate to use the CKD-EPI formula to estimate RRF of PD patients.
引用
收藏
页码:1941 / 1947
页数:7
相关论文
共 30 条
[1]   STRUCTURE AND EXPRESSION OF THE HUMAN CYSTATIN-C GENE [J].
ABRAHAMSON, M ;
OLAFSSON, I ;
PALSDOTTIR, A ;
ULVSBACK, M ;
LUNDWALL, A ;
JENSSON, O ;
GRUBB, A .
BIOCHEMICAL JOURNAL, 1990, 268 (02) :287-294
[2]  
Al-Wakeel JS., SERUM CYSTATIN C SUR
[3]  
APPLE FS, 1989, CLIN CHEM, V35, P312
[4]  
Bargman JM, 2001, J AM SOC NEPHROL, V12, P2158, DOI 10.1681/ASN.V12102158
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Caravaca F, 2002, PERITON DIALYSIS INT, V22, P414
[7]   Estimation of residual glomerular filtration rate in peritoneal dialysis patients using cystatin C: comparison with 51Cr-EDTA clearance [J].
Carter, Joanne L. ;
Lane, Catherine E. ;
Fan, Stanley L. ;
Lamb, Edmund J. .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2011, 26 (11) :3729-3732
[8]   Serum cystatin C as a new marker for noninvasive estimation of glomerular filtration rate and as a marker for early renal impairment [J].
Coll, E ;
Botey, A ;
Alvarez, L ;
Poch, E ;
Quintó, L ;
Saurina, A ;
Vera, M ;
Piera, C ;
Darnell, A .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 36 (01) :29-34
[9]   Relationship of serum cystatin C to peritoneal and renal clearance measures in peritoneal dialysis: A cross-sectional study [J].
Delaney, Michael P. ;
Stevens, Paul E. ;
Al Hasani, Mohammed ;
Stowe, Helen J. ;
Judge, Caroline ;
Lamb, Edmund J. .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2008, 51 (02) :278-284
[10]   Hemodialysis versus peritoneal dialysis: A comparison of adjusted mortality rates [J].
Fenton, SSA ;
Schaubel, DE ;
Desmeules, M ;
Morrison, HI ;
Mao, Y ;
Copleston, P ;
Jeffery, JR ;
Kjellstrand, CM .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 30 (03) :334-342