Mechanism model-based and data-driven approach for the diagnosis of solid oxide fuel cell stack leakage

被引:26
|
作者
Xu, Yuan-wu [1 ]
Wu, Xiao-long [2 ]
Zhong, Xiao-bo [1 ]
Zhao, Dong-qi [1 ]
Sorrentino, Marco [3 ]
Jiang, Jianhua [1 ]
Jiang, Chang [4 ]
Fu, Xiaowei [5 ]
Li, Xi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Artificial Intelligence & Automat, Key Lab Imaging Proc & Intelligent Control, Wuhan 430074, Hubei, Peoples R China
[2] Nanchang Univ, Sch Informat Engn, Nanchang 330031, Jiangxi, Peoples R China
[3] Univ Salerno, Dept Ind Engn, Via Giovanni Paolo II 132, I-84084 Fisciano, SA, Italy
[4] Wuhan Intelligent Equipment Ind Inst, Wuhan 430075, Hubei, Peoples R China
[5] Wuhan Univ Sci & Technol, Coll Comp Sci & Technol, Hubei Prov Key Lab Intelligent Informat Proc & Re, Wuhan 430081, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Solid oxide fuel cell (SOFC); Fault diagnosis; Gas leakages; Model-based; Data-driven; FAULT-DIAGNOSIS; TEMPERATURE DISTRIBUTION; SOFC SYSTEM; METHODOLOGY; STATE; PERFORMANCE; VALIDATION; PREDICTION; OBSERVER; CIRCUIT;
D O I
10.1016/j.apenergy.2021.116508
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Safety and reliability are key objectives for the efficient operation of solid oxide fuel cell (SOFC) power generation systems. Out of many possible faults, the gas leakage of SOFC stack remains a critical issue that leading to efficiency reduction or even degradation. Therefore, the real-time monitoring and diagnosis of gas leakage in the power generation systems are not only an important premise to improve the efficiency, but also can develop the corresponding fault-tolerant strategy for ensuring the system performance. Motivated by this fact, an on-line fault diagnosis scheme based on mechanism model and data-driven method is proposed to monitor and diagnose the gas leakage of the stack. Firstly, the two-state mechanism model of the SOFC stack is established, which can effectively describe the temperature of the fuel layer and air layer. Then, easily-measured stack inputs and outputs are selected, and a novel gas leakage state estimator combined with unscented Kalman filter (UFK) is developed to reconstruct the leakage state. Furthermore, an adaptive thresholds generator is designed to enhance the robustness of the diagnostic scheme. The performance of the fault diagnosis scheme under different leakage scenarios is evaluated, and the simulation results demonstrate the effectiveness of the proposed scheme. The sudden stack fuel leakage failure that occurred in the stable power generation experiment further illustrates the practicability of the scheme. The proposed fault diagnosis scheme has good practicability and can guide the next step compensates for leakage.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Solid oxide fuel cell fault diagnosis and ageing estimation based on wavelet transform approach
    Pahon, E.
    Steiner, N. Yousfi
    Jemei, S.
    Hissel, D.
    Pera, M. C.
    Wang, K.
    Mocoteguy, P.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (31) : 13678 - 13687
  • [32] Integrated data-driven model-based approach to condition monitoring of the wind turbine gearbox
    Qian, Peng
    Ma, Xiandong
    Cross, Philip
    IET RENEWABLE POWER GENERATION, 2017, 11 (09) : 1177 - 1185
  • [33] Residual-Hypergraph Convolution Network: A Model-Based and Data-Driven Integrated Approach for Fault Diagnosis in Complex Equipment
    Xia, Liqiao
    Liang, Yongshi
    Zheng, Pai
    Huang, Xiao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [34] Optimizing the homogeneity and efficiency of a solid oxide electrolysis cell based on multiphysics simulation and data-driven surrogate model
    Chi, Yingtian
    Yokoo, Kentaro
    Nakajima, Hironori
    Ito, Kohei
    Lin, Jin
    Song, Yonghua
    JOURNAL OF POWER SOURCES, 2023, 562
  • [35] Model-based development of a fault signature matrix to improve solid oxide fuel cell systems on-site diagnosis
    Polverino, Pierpaolo
    Pianese, Cesare
    Sorrentino, Marco
    Marra, Dario
    JOURNAL OF POWER SOURCES, 2015, 280 : 320 - 338
  • [36] A Hybrid Experimental Model of a Solid Oxide Fuel Cell Stack
    Wu, Xiao-Juan
    Zhu, Xin-Jian
    Cao, Guang-Yi
    Tu, Heng-Yong
    Hu, Wan-Qi
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2009, 6 (01): : 0110131 - 0110134
  • [37] Helical fault diagnosis model based on data-driven incremental mergence
    Liu, Jing
    An, Yacheng
    Dou, Runliang
    Ji, Haipeng
    Liu, Yankai
    COMPUTERS & INDUSTRIAL ENGINEERING, 2018, 125 : 517 - 532
  • [38] Control of a solid oxide fuel cell stack based on unmodeled dynamic compensations
    Wu, Xiaojuan
    Wang, Junhao
    Hao, Jiaqi
    Li, Xi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (49) : 22500 - 22510
  • [39] Fault Diagnosis of Solid Oxide Fuel Cell Based on a Supervised Self-Organization Map Model
    Wu, XiaoJuan
    Liu, Hongtan
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2015, 12 (03):
  • [40] A model-based approach for current voltage analyses to quantify degradation and fuel distribution in solid oxide fuel cell stacks
    Linder, Markus
    Hocker, Thomas
    Meier, Christoph
    Holzer, Lorenz
    Friedrich, K. Andreas
    Iwanschitz, Boris
    Mai, Andreas
    Schuler, J. Andreas
    JOURNAL OF POWER SOURCES, 2015, 288 : 409 - 418