Preconcentration and determination of iron and copper in spice samples by cloud point extraction and flow injection flame atomic absorption spectrometry

被引:67
作者
Sahin, Cigdem Arpa [1 ]
Tokgoz, Ilknur [1 ]
Bektas, Sema [1 ]
机构
[1] Hacettepe Univ, Dept Chem, TR-06800 Ankara, Turkey
关键词
Cloud point extraction; Preconcentration; Flow injection; Iron; Copper; Flame atomic absorption spectrometry; Neutral Red; Spice samples; OPTICAL-EMISSION-SPECTROMETRY; MICELLE MEDIATED METHODOLOGY; SOLID-PHASE EXTRACTION; BIOLOGICAL SAMPLES; WATER SAMPLES; ONLINE INCORPORATION; NATURAL-WATERS; FOOD SAMPLES; CADMIUM; SEPARATION;
D O I
10.1016/j.jhazmat.2010.05.018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A flow injection (FI) cloud point extraction (CPE) method for the determination of iron and copper by flame atomic absorption spectrometer (FAAS) has been improved. The analytes were complexed with 3-amino-7-dimethylamino-2-methylphenazine (Neutral Red, NR) and octylphenoxypolyethoxyethanol (Triton X-114) was added as a surfactant. The micellar solution was heated above 50 degrees C and loaded through a column packed with cotton for phase separation. Then the surfactant-rich phase was eluted using 0.05 mol L-1 H2SO4 and the analytes were determined by FAAS. Chemical and flow variables influencing the instrumental and extraction conditions were optimized. Under optimized conditions for 25 mL of preconcentrated solution, the enrichment factors were 98 and 69, the limits of detection (3s) were 0.7 and 0.3 ng mL(-1), the limits of quantification (10s) were 2.2 and 1.0 ng mL(-1) for iron and copper, respectively. The relative standard deviation (RSD) for ten replicate measurements of 10 ng mL(-1) iron and copper were 2.1% and 1.8%, respectively. The proposed method was successfully applied to determination of iron and copper in spice samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 44 条
[1]  
Baytak S, 2007, ACTA CHIM SLOV, V54, P385
[2]   Cloud point extraction as a procedure of separation and pre-concentration for metal determination using spectroanalytical techniques: A review [J].
Bezerra, MD ;
Arruda, MAZ ;
Ferreira, SLC .
APPLIED SPECTROSCOPY REVIEWS, 2005, 40 (04) :269-299
[3]   Determination of cadmium at ultra-trace levels by CPE-molecular fluorescence combined methodology [J].
Carolina Talio, Maria ;
Luconi, Marta O. ;
Masi, Adriana N. ;
Fernandez, Liliana P. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 170 (01) :272-277
[4]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222
[5]   Solid-phase extraction of Cu, Co and Pb on oxidized single-walled carbon nanotubes and their determination by inductively coupled plasma mass spectrometry [J].
Chen, Shizhong ;
Liu, Cheng ;
Yang, Ming ;
Lu, Dengbo ;
Zhu, Li ;
Wang, Zhan .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 170 (01) :247-251
[6]   Determination of Ag and Au in geological samples by flame atomic absorption spectrometry after cloud point extraction [J].
da Silva, MAM ;
Frescura, VLA ;
Aguilera, FJN ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (12) :1369-1373
[7]  
Dalali N, 2008, TURK J CHEM, V32, P561
[8]   Determination of furosemide in urine by HPLC with preconcentration by micellar-extraction [J].
Doroshchuk, V. A. ;
Gonta, N. A. ;
Drozdova, M. V. ;
Kulichenko, S. A. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 64 (10) :1054-1058
[9]   Online incorporation of cloud point extraction to flow injection analysis [J].
Fang, Q ;
Du, M ;
Huie, CW .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3502-3505
[10]  
Fernandez-Band B. S., 2004, ANAL CHIM ACTA, V502, P173