Renewable three-dimensional Prussian blue modified carbon ceramic electrode

被引:34
作者
Wang, P [1 ]
Yuan, Y [1 ]
Wang, XP [1 ]
Zhu, GY [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Electroanalyt Chem Lab, Changchun 130022, Peoples R China
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2000年 / 493卷 / 1-2期
关键词
Prussian blue; sol-gel; carbon ceramic electrode; electrocatalytic oxidation; hydrazine;
D O I
10.1016/S0022-0728(00)00339-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Prussian blue (PB) supported on graphite powder was prepared by the chemical deposition technique and subsequently dispersed into methyltrimethoxysilane-derived gels to yield a conductive graphite organosilicate composite. The composite was used as the electrode material to fabricate a three-dimensional PB-modified electrode. PB acts as a catalyst, graphite powder ensures conductivity by percolation, the silicate provides a rigid porous backbone, and the methyl groups endow hydrophobicity and thus limit the wetting section of the modified electrode. The chemically modified electrode can electrocatalyze the oxidation of hydrazine, and exhibits a distinct advantage of polishing in the event of surface fouling, as well as simple preparation, good chemical and mechanical stability and good repeatability of surface-renewal. Hydrodynamic voltammetric experiments were performed to characterize the electrode as an amperometric sensor for the determination of hydrazine. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [11] Electrocatalytic oxidation of hydrazine at a Prussian Blue-modified glassy carbon electrode
    Scharf, U
    Grabner, EW
    ELECTROCHIMICA ACTA, 1996, 41 (02) : 233 - 239
  • [12] Behavior of PQQ glucose dehydrogenase on Prussian blue-modified carbon electrode
    Laurinavicius, Valdas
    Kurtinaitiene, Bogumila
    Stankeviciute, Rasa
    ELECTROANALYSIS, 2008, 20 (13) : 1391 - 1395
  • [13] Ceramic carbon electrode modified with butyloferrocene
    Saczek-Maj, M
    Opallo, M
    ELECTROANALYSIS, 2003, 15 (5-6) : 566 - 572
  • [14] Electrocatalytic Oxidation and Detection of Hydrazine at Glassy Carbon Modified Electrode with Prussian Blue-Complex by Sol-Gel Method
    Ershad, Sohrab
    Danandeh, Zahra
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (08): : 988 - 999
  • [15] Nonenzymatic hydrogen peroxide sensor based on a Prussian Blue-modified carbon ionic liquid electrode
    Li, Yonghong
    Liu, Xiaoying
    Zeng, Xiandong
    Liu, Yong
    Liu, Xinsheng
    Wei, Wanzhi
    Luo, Shenglian
    MICROCHIMICA ACTA, 2009, 165 (3-4) : 393 - 398
  • [16] An amperometric biosensor using Prussian blue modified electrode
    Yi, In-Je
    Kim, Ju-Ho
    Kang, C. J.
    Park, Jaehyun
    Kim, Yong-Sang
    ECO-MATERIALS PROCESSING & DESIGN VII, 2006, 510-511 : 746 - 749
  • [17] Determination of Rutin in Drinks Using an Electrode Modified with Carbon Nanotubes-Prussian Blue
    Nagles, Edgar
    Penagos-Llanos, Johisner
    Garcia-Beltran, Olimpo
    Hurtado, John
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (05) : 504 - 511
  • [18] Determination of Rutin in Drinks Using an Electrode Modified with Carbon Nanotubes-Prussian Blue
    Edgar Nagles
    Johisner Penagos-Llanos
    Olimpo García-Beltrán
    John Hurtado
    Journal of Analytical Chemistry, 2018, 73 : 504 - 511
  • [19] Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue
    E. Suprun
    G. Evtugyn
    H. Budnikov
    F. Ricci
    D. Moscone
    G. Palleschi
    Analytical and Bioanalytical Chemistry, 2005, 383 : 597 - 604
  • [20] Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue
    Suprun, E
    Evtugyn, G
    Budnikov, H
    Ricci, F
    Moscone, D
    Palleschi, G
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (04) : 597 - 604