Outcomes After Patch Use in Rotator Cuff Repair

被引:71
|
作者
Steinhaus, Michael E. [1 ]
Makhni, Eric C. [2 ]
Cole, Brian J. [2 ]
Romeo, Anthony A. [2 ]
Verma, Nikhil N. [2 ]
机构
[1] Hosp Special Surg, 535 E 70th St, New York, NY 10021 USA
[2] Rush Univ, Med Ctr, Dept Orthopaed, 1611 W Harrison St,Ste 300, Chicago, IL 60612 USA
基金
美国国家卫生研究院;
关键词
SMALL-INTESTINE SUBMUCOSA; ARTHROSCOPIC REPAIR; FOLLOW-UP; TEARS; AUGMENTATION; INTEGRITY; TENDON; RECONSTRUCTION; ALLOGRAFT; REPLACEMENT;
D O I
10.1016/j.arthro.2016.02.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To provide a comprehensive review of clinical outcomes and retear rates after patch use in rotator cuff repair, and to determine the differences between available graft types and techniques. Methods: A systematic review was conducted from database (PubMed, Medline, Scopus, Embase) inception to January 2015 for English-language articles reporting outcome data with 9 months' minimum follow-up. Studies were assessed by 2 reviewers who collected pertinent data, with outcomes combined to generate frequency-weighted means. Results: Twenty-four studies met the inclusion criteria. The frequency-weighted mean age was 61.9 years with 35.4 months' follow-up. The mean improvements in postoperative range of motion in the forward elevation, abduction, external rotation, and internal rotation planes were 58.6 degrees, 66.2 degrees, 16.6 degrees, and 16.1 degrees, respectively, and postoperative abduction strength improved by 3.84 kg. American Shoulder and Elbow Surgeons, University of Californiae-Los Angeles, Constant, Penn, and Oxford scores improved by 39.3, 10.7, 40.8, 34.4, and 17.6, respectively. Augmentation and interposition techniques showed similar improvements in range of motion, strength, and patient-reported outcomes (PROs), whereas xenografts showed less improvement in PROs compared with other graft types. Studies reported improvements in pain and activities of daily living (ADLs), with greater than 90% overall satisfaction, although few patients (13%) were able to return to preinjury activity. Whereas interposition and augmentation techniques showed similar improvements in pain and ADLs, xenografts showed less improvement in ADLs than other graft types. The overall retear rate was 25%, with rates of 34% and 12% for augmentation and interposition, respectively, and rates of 44%, 23%, and 15% for xenografts, allografts, and synthetic grafts, respectively. Conclusions: We report improvements in clinical and functional outcomes, with similar results for augmentation and interposition techniques, whereas xenografts showed less improvement than synthetic grafts and allografts in PROs and ADLs. Retear rates may be lower with the interposition technique or in patients with synthetic grafts or allografts.
引用
收藏
页码:1676 / 1690
页数:15
相关论文
共 50 条
  • [41] Revision Rotator Cuff Repair
    Keener, Jay D.
    CLINICS IN SPORTS MEDICINE, 2012, 31 (04) : 713 - +
  • [42] Failed rotator cuff repair
    Desmoineaux, Pierre
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (01) : S63 - S73
  • [43] Retear Rate in the Late Postoperative Period After Arthroscopic Rotator Cuff Repair
    Kim, Jae Hwa
    Hong, In Tae
    Ryu, Keun Jung
    Bong, Sun Tae
    Lee, Yoon Seok
    Kim, Jang Hwan
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (11) : 2606 - 2613
  • [44] Functional outcomes after bilateral arthroscopic rotator cuff repair
    Aleem, Alexander W.
    Syed, Usman Ali M.
    Wascher, Jocelyn
    Zoga, Adam C.
    Close, Koby
    Abboud, Joseph A.
    Cohen, Steven B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (10) : 1668 - 1673
  • [45] Biological Augmentation in Repair and Reconstruction of the Rotator Cuff
    Ziegler, Connor G.
    Edgar, Cory
    Cote, Mark
    Mazzocca, Augustus D.
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2015, 23 (01) : 2 - 10
  • [46] Interposition Graft Repair of Irreparable Rotator Cuff Tears: A Review of Biomechanics and Clinical Outcomes
    Sunwoo, Joo Y.
    Murrell, George A. C.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (19) : E829 - E838
  • [47] Early anchor displacement after arthroscopic rotator cuff repair
    Skaliczki, Gbor
    Paladini, Paolo
    Merolla, Giovanni
    Campi, Fabrizio
    Porcellini, Giuseppe
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (05) : 915 - 920
  • [48] Failure With Continuity in Rotator Cuff Repair "Healing"
    McCarron, Jesse A.
    Derwin, Kathleen A.
    Bey, Michael J.
    Polster, Joshua M.
    Schils, Jean P.
    Ricchetti, Eric T.
    Iannotti, Joseph P.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (01) : 134 - 141
  • [49] Arthroscopic Transosseous Rotator Cuff Repair: Technical Note, Outcomes, and Complications
    Black, Eric M.
    Lin, Albert
    Srikumaran, Uma
    Jain, Nitin
    Freehill, Michael T.
    ORTHOPEDICS, 2015, 38 (05) : E352 - E358
  • [50] Benefits of Patch Augmentation on Rotator Cuff Repair: A Systematic Review and Meta-analysis
    Lugnani de Andrade, Andre Luis
    Garcia, Thiago Alves
    Brandao, Henrique de Sancti
    Sardeli, Amanda Veiga
    Mouraria, Guilherme Grisi
    Belangero, William Dias
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2022, 10 (03)