Surface Water Source Heat Pump Air Conditioning System Simulation and Operation Performance Analysis

被引:9
|
作者
Lv, Nan [1 ]
Zhang, Qing [1 ]
Wu, Dongsheng [2 ]
Chen, Zhenqian [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210000, Jiangsu, Peoples R China
[2] Southeast Univ, Architects & Engn Co Ltd, Nanjing 210000, Jiangsu, Peoples R China
关键词
Surface water source heat pump system; Simulation model; Operation performance;
D O I
10.1016/j.proeng.2015.09.170
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper established a heat pump system model containing heat pump unit model, AC load model and heat exchanger model utilizing the mass and energy balance and the structure's designing method. This paper also developed the surface water source heat pump air conditioning system simulation program by Visual Basic, and verified the simulation by the actual engineering project. In addition, this paper explored the impact of the surface water temperature and heat exchanger structure on the heat pump air conditioning system operation. The results shows that one degree drop of the surface water temperature leads to 2.3 per cent increase of performance coefficient and a 100m added length of the closed-loop surface water heat exchanger tube leads to 0.08 per cent increase of performance coefficient. (C) The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the organizing committee of ISHVAC-COBEE 2015
引用
收藏
页码:1880 / 1886
页数:7
相关论文
共 50 条
  • [1] Performance analysis of water source heat pump air-conditioning system for Haihe River as heat source
    Fu, Hailing
    Li, Jiaxin
    Wang, Xinyao
    Xiong, Wenlin
    Liu, Wenwen
    Sun, Ranran
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 171 : 38 - 50
  • [2] Simulation and analysis on thermodynamic performance of surface water source heat pump system
    Lv, Nan
    Zhang, Qing
    Chen, Zhenqian
    Wu, Dongsheng
    BUILDING SIMULATION, 2017, 10 (01) : 65 - 73
  • [3] Simulation and analysis on thermodynamic performance of surface water source heat pump system
    Nan Lv
    Qing Zhang
    Zhenqian Chen
    Dongsheng Wu
    Building Simulation, 2017, 10 : 65 - 73
  • [4] Simulation analysis on operation performance of a hybrid heat pump system integrating photovoltaic/thermal and air source
    Li, Zuqiang
    Huang, Xinghua
    APPLIED THERMAL ENGINEERING, 2022, 200
  • [5] A raw water source heat pump air-conditioning system
    Cho, Yong
    Yun, Rin
    ENERGY AND BUILDINGS, 2011, 43 (11) : 3068 - 3073
  • [6] Integrated operation of PV assisted ground source heat pump and air source heat pump system: Performance analysis and economic optimization
    Zheng, Zhihang
    Zhou, Jin
    Xu, Feng
    Zhang, Rongpeng
    Deng, Guang
    ENERGY CONVERSION AND MANAGEMENT, 2022, 269
  • [7] Out low level heat source and water loop heat pump air conditioning system
    Jiang, YQ
    Yao, Y
    Ma, ZL
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 563 - 570
  • [8] Performance analysis of electric vehicle heat pump air conditioning system
    Li, Ming
    Xue, Qing-Feng
    Zhang, Ke-Xin
    Lyu, Ran
    Wei, Chang-Hua
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2021, 51 (06): : 1943 - 1952
  • [9] Operation performance of air source heat pump system for space heating in Tianjin
    School of Mechanical Engineering, Tianjin University, Tianjin 300072, China
    Trans. Tianjin Univ., 2007, 2 (137-141): : 137 - 141
  • [10] Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin
    赵军
    陈雁
    曲航
    李新国
    Transactions of Tianjin University, 2007, (02) : 137 - 141