Cardiac magnetic resonance T1 mapping. Part 1: Aspects of acquisition and evaluation

被引:28
|
作者
Reiter, Gert [1 ,2 ]
Reiter, Clemens [2 ]
Kraeuter, Corina [2 ,3 ]
Fuchsjaeger, Michael [2 ]
Reiter, Ursula [2 ]
机构
[1] Siemens Healthcare Diagnost GmbH, Res & Dev, Strassgangerstr 315, A-8054 Graz, Austria
[2] Med Univ Graz, Div Gen Radiol, Dept Radiol, Auenbruggerpl 19-P, A-8036 Graz, Austria
[3] Graz Univ Technol, Inst Med Engn, Stremayrgasse 16-3, A-8010 Graz, Austria
关键词
Cardiac magnetic resonance; T1; mapping; Extracellular volume; Normal range; EXTRACELLULAR VOLUME FRACTION; MYOCARDIUM INTRAINDIVIDUAL ASSESSMENT; INVERSION-RECOVERY MOLLI; REFERENCE VALUES; NATIVE T1; TISSUE CHARACTERIZATION; ADENOSINE STRESS; PULSE SEQUENCE; BREATH-HOLD; VALIDATION;
D O I
10.1016/j.ejrad.2018.10.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
While an enormous number of studies have documented pathological alterations of the myocardial native longitudinal relaxation time (T1) and the fraction of the extracellular myocardial volume (ECV), it has also become clear that continuously evolving T1 mapping sequence, acquisition and evaluation techniques have a substantial impact on quantitative results, making the translation of reported findings into routine clinical use particularly challenging. To provide a basis for the discussion of pathological myocardial T1 and ECV alterations, the present review aims to summarize the methodological aspects of myocardial T1 mapping along with technical and physiological factors influencing results and normal ranges of myocardial native T1 and ECV reported across studies.
引用
收藏
页码:223 / 234
页数:12
相关论文
共 50 条
  • [41] Arrhythmia Insensitive Rapid Cardiac T1 Mapping Pulse Sequence
    Fitts, Michelle
    Breton, Elodie
    Kholmovski, Eugene G.
    Dosdall, Derek J.
    Vijayakumar, Sathya
    Hong, Kyung P.
    Ranjan, Ravi
    Marrouche, Nassir F.
    Axel, Leon
    Kim, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (05) : 1274 - 1282
  • [42] Diffuse myocardial fibrosis evaluation using cardiac magnetic resonance T1 mapping: sample size considerations for clinical trials
    Songtao Liu
    Jing Han
    Marcelo S Nacif
    Jacquin Jones
    Nadine Kawel
    Peter Kellman
    Christopher T Sibley
    David A Bluemke
    Journal of Cardiovascular Magnetic Resonance, 14
  • [43] T1 mapping in dilated cardiomyopathy with cardiac magnetic resonance: quantification of diffuse myocardial fibrosis and comparison with endomyocardial biopsy
    Siepen, Fabian Aus Dem
    Buss, Sebastian J.
    Messroghli, Daniel
    Andre, Florian
    Lossnitzer, Dirk
    Seitz, Sebastian
    Keller, Marius
    Schnabel, Philipp A.
    Giannitsis, Evangelos
    Korosoglou, Grigorios
    Katus, Hugo A.
    Steen, Henning
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (02) : 210 - 216
  • [44] T1 Mapping in Discrimination of Hypertrophic Phenotypes: Hypertensive Heart Disease and Hypertrophic Cardiomyopathy Findings From the International T1 Multicenter Cardiovascular Magnetic Resonance Study
    Hinojar, Rocio
    Varma, Niharika
    Child, Nick
    Goodman, Benjamin
    Jabbour, Andrew
    Yu, Chung-Yao
    Gebker, Rolf
    Doltra, Adelina
    Kelle, Sebastian
    Khan, Sitara
    Rogers, Toby
    Ucar, Eduardo Arroyo
    Cummins, Ciara
    Carr-White, Gerald
    Nagel, Eike
    Puntmann, Valentina O.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (12)
  • [45] Extracellular matrix expansion by cardiac magnetic resonance T1 mapping- validation with myocardial biopsy
    Andreas Kammerlander
    Caroline Tufaro
    Alina F Bachmann
    Beatrice A Marzluf
    Stefan Aschauer
    Andreas Greiser
    Diana Bonderman
    Julia Mascherbauer
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [46] Blood T1*correction increases accuracy of extracellular volume measurements using 3T cardiovascular magnetic resonance: Comparison of T1 and T1*maps
    Shang, Yongning
    Zhang, Xiaochun
    Zhou, Xiaoyue
    Greiser, Andreas
    Zhou, Zhengwei
    Li, Debiao
    Wang, Jian
    SCIENTIFIC REPORTS, 2018, 8
  • [47] MOLLI and AIR T1 mapping pulse sequences yield different myocardial T1 and ECV measurements
    Hong, KyungPyo
    Kim, Daniel
    NMR IN BIOMEDICINE, 2014, 27 (11) : 1419 - 1426
  • [48] Saturation Recovery Single-Shot Acquisition (SASHA) for Myocardial T1 Mapping
    Chow, Kelvin
    Flewitt, Jacqueline A.
    Green, Jordin D.
    Pagano, Joseph J.
    Friedrich, Matthias G.
    Thompson, Richard B.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 2082 - 2095
  • [49] Regional amyloid distribution and impact on mortality in light-chain amyloidosis: a T1 mapping cardiac magnetic resonance study
    Wan, Ke
    Li, Weihao
    Sun, Jiayu
    Xu, Yuanwei
    Wang, Jie
    Liu, Hong
    Dong, Yang
    Cheng, Wei
    Zhang, Qing
    Zeng, Zhi
    Zhou, Xiaoyue
    Han, Yuchi
    Chen, Yucheng
    AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2019, 26 (01): : 45 - 51
  • [50] Cardiac magnetic resonance imaging T1 mapping and late gadolinium enhancement entropy: Prognostic value in patients with systemic sclerosis
    Yamamoto, Atsushi
    Nagao, Michinobu
    Shirai, Yurie
    Nakao, Risako
    Sakai, Akiko
    Kaneko, Koichiro
    Arashi, Hiroyuki
    Minami, Yuichiro
    Sakai, Shuji
    Yamaguchi, Junichi
    JOURNAL OF CARDIOLOGY, 2023, 82 (05) : 343 - 348