A Modified Hybrid DC Circuit Breaker With Reduced Arc for Low Voltage DC Grids

被引:21
作者
Ajmal, C. N. Muhammed [1 ]
Raghavendra, I. Venkata [1 ]
Naik, Satish [1 ]
Ray, Anindya [2 ]
Krishnamoorthy, Harish S. [3 ]
机构
[1] Indian Inst Technol Dharwad, Dept Elect Engn, Dharwad 580011, Karnataka, India
[2] Sandia Natl Labs, Energy Storage Tech & Syst, Albuquerque, NM 87123 USA
[3] Univ Houston, Dept Elect & Comp Engn, Cullen Coll Engn, Houston, TX 77004 USA
关键词
Switches; Capacitors; Circuit faults; Circuit breakers; Insulated gate bipolar transistors; Fault currents; Topology; Hybrid circuit breaker (HCB); LVDC; mechanical circuit breaker; varistor;
D O I
10.1109/ACCESS.2021.3115456
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The increasing demand for the development and utilization of renewable energy resources has lead to a growing interest in the development of LVDC systems. The dc grid provides more flexibility in integrating different forms of renewable energy sources effectively. However, the lack of a reliable protection mechanism remains the main drawback in the growth of dc distribution systems. Unlike ac systems, the absence of a natural zero crossing in dc systems for arc extinction makes the use of a conventional mechanical circuit breaker (MCB) a less reliable solution. The use of a solid-state circuit breaker (SSCB) results in fast fault interruption but reduces the overall efficiency of the system due to the on-state voltage drop of the semiconductor devices. A hybrid circuit breaker (HCB) combining MCB and SSCB yields better static and dynamic performances but the main challenges remains in the demagnetization of the transmission line inductance after a fault interruption and an arc formation between the MCB contacts. This paper proposes a hybrid circuit breaker (HCB) which is suitable for fast fault interruption in low voltage dc (LVDC) systems while alleviating the above issues. Proposed topology employs a semiconductor switch as well as an actively switched capacitor branch in parallel with the main mechanical breaker to facilitate fast current commutation during a fault. The mechanical breaker forming the main branch is turned off at zero voltage. This eliminates the arc formation across the moving contacts of the breaker. Moreover, the fault interruption process does not require a varistor for network demagnetization following the fault current commutation. This paper also presents a discharging mechanism for the capacitor in a practical implementation. Operation of the proposed dc circuit breaker is evaluated through a prototype tested in the laboratory.
引用
收藏
页码:132267 / 132277
页数:11
相关论文
共 22 条
[1]  
Abedrabbo Mudar, 2017, 2017 19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe), DOI 10.23919/EPE17ECCEEurope.2017.8099371
[2]  
[Anonymous], 2018, BUILDING RELIABLE EL
[3]  
Callavik M., 2012, Technical Paper
[4]   A Series-Stacked Power Delivery Architecture With Isolated Differential Power Conversion for Data Centers [J].
Candan, Enver ;
Shenoy, Pradeep S. ;
Pilawa-Podgurski, Robert C. N. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (05) :3690-3703
[5]  
Davidson C., 2015, AC 600 POWER TRANSMI, P1, DOI DOI 10.1049/CP.2015.0021
[6]  
Gao L, 2018, INT SYM DISCH ELECTR, P615, DOI 10.1109/DEIV.2018.8537020
[7]  
Mackey L, 2018, IEEE ENER CONV, P7150, DOI 10.1109/ECCE.2018.8557825
[8]  
Nascimento TP, 2014, IEEE INT CONF AUTON, P2, DOI 10.1109/ICARSC.2014.6849754
[9]  
Pei X, 2016, IEEE IND ELEC, P3799, DOI 10.1109/IECON.2016.7793492
[10]   Solid-State Circuit Breaker Protection for DC Shipboard Power Systems: Breaker Design, Protection Scheme, Validation Testing [J].
Qi, Li ;
Cairoli, Pietro ;
Pan, Zach ;
Tschida, Colin ;
Wang, Zhenyuan ;
Ramanan, V. R. ;
Raciti, Luca ;
Antoniazzi, Antonello .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (02) :952-960