Numerical Simulation Comparison of Two Reactor Configurations for Chemical Looping Combustion and Chemical Looping With Oxygen Uncoupling

被引:20
作者
Hamilton, Matthew A. [1 ]
Whitty, Kevin J. [1 ]
Lighty, JoAnn S. [1 ]
机构
[1] Univ Utah, 50 South Cent Campus Dr,Room 3290, Salt Lake City, UT 84112 USA
来源
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME | 2016年 / 138卷 / 04期
关键词
FLUIDIZED-BED; SCALING RELATIONSHIPS; SOLID FUELS; DESIGN; OPERATION; CFD; KINETICS; MODEL; CLOU; FLOW;
D O I
10.1115/1.4033108
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Chemical looping with oxygen uncoupling (CLOU) is a carbon capture technology that utilizes a metal oxide as an oxygen carrier to selectively separate oxygen from air and release gaseous O-2 into a reactor where fuel, such as coal, is combusted. Previous research has addressed reactor design for CLOU systems, but little direct comparison between different reactor designs has been performed. This study utilizes Barracuda-VR VR for comparison of two system configurations, one uses circulating fluidized beds (CFB) for both the air reactor (AR) and fuel reactor (FR) and another uses bubbling fluidized beds for both reactors. Initial validation of experimental and computational fluid dynamic (CFD) simulations was performed to show that basic trends are captured with the CFD code. The CFD simulations were then used to perform comparison of key performance parameters such as solids circulation rate and reactor residence time, pressure profiles in the reactors and loopseals, and particle velocities in different locations of the reactor as functions of total solids inventory and reactor gas flows. Using these simulation results, it was determined that the dual CFB system had larger range for solids circulation rate before choked flow was obtained. Both systems had similar particle velocities for the bottom 80% of particle mass, but the bubbling bed (BB) obtained higher particle velocities as compared to the circulating fluidized-bed FR, due to the transport riser. As a system, the results showed that the dual CFB configuration allowed better control over the range of parameters tested.
引用
收藏
页数:9
相关论文
共 50 条
[1]   The multiphase particle-in-cell (MP-PIC) method for dense particulate flows [J].
Andrews, MJ ;
ORourke, PJ .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1996, 22 (02) :379-402
[2]  
[Anonymous], 2014, Barracuda Series 16 Training Manual, P1
[3]  
Basu P., 1991, Circulating Fluidized Bed Boilers
[4]   Design and operation of a 10 kWth chemical-looping combustor for solid fuels -: Testing with South African coal [J].
Berguerand, Nicolas ;
Lyngfelt, Anders .
FUEL, 2008, 87 (12) :2713-2726
[5]   Chemical-Looping Combustion of Petroleum Coke Using Ilmenite in a 10 kWth Unit-High-Temperature Operation [J].
Berguerand, Nicolas ;
Lyngfelt, Anders .
ENERGY & FUELS, 2009, 23 (10) :5257-5268
[6]   Design study of a 150 kWth double loop circulating fluidized bed reactor system for chemical looping combustion with focus on industrial applicability and pressurization [J].
Bischi, A. ;
Langorgen, O. ;
Saanum, I. ;
Bakken, J. ;
Seljeskog, M. ;
Bysveen, M. ;
Morin, J. -X. ;
Bolland, O. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (03) :467-474
[7]  
Chapman PJ., 2014, Proc. 11th Int. Conf. Fluid. Bed Technol, P469
[8]  
Clark S. M., 2012, AICHE ANN M C P AICH, p9p
[9]   Oxidation Kinetics of Cu2O in Oxygen Carriers for Chemical Looping with Oxygen Uncoupling [J].
Clayton, Christopher K. ;
Sohn, H. Y. ;
Whitty, Kevin J. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (08) :2976-2986
[10]   Measurement and modeling of decomposition kinetics for copper oxide-based chemical looping with oxygen uncoupling [J].
Clayton, Christopher K. ;
Whitty, Kevin J. .
APPLIED ENERGY, 2014, 116 :416-423