Compact Metamaterial-based Coil Element for Combined 1H/23Na MRI at 7 T

被引:0
|
作者
Svejda, Jan Taro [1 ]
Rennings, Andreas
Erni, Daniel
机构
[1] Univ Duisburg Essen, Fac Engn, Gen & Theoret Elect Engn ATE, D-47048 Duisburg, Germany
来源
METANANO 2019 | 2020年 / 1461卷
关键词
D O I
10.1088/1742-6596/1461/1/012173
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
High static magnetic flux densities in the field of magnetic resonance imaging (MRI) allow X-nuclei-based imaging and spectroscopy as well as the utilization of electromagnetic metamaterials. A compact dual-tuned coil element based on a metamaterial transmission line which achieves a quarter-wave resonance at the two distinct operating frequencies of the hydrogen and sodium nuclei is presented. In addition, first combined H-1/Na-23 MRI measurement results from a structured phantom are shown and discussed.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] 23Na and 1H NMR microimaging of intact plants
    Olt, S
    Krötz, E
    Komor, E
    Rokitta, M
    Haase, A
    JOURNAL OF MAGNETIC RESONANCE, 2000, 144 (02) : 297 - 304
  • [22] Practical design of a 4 Tesla double-tuned RF surface coil for interleaved 1H and 23Na MRI of rat brain
    Alecci, M.
    Romanzetti, S.
    Kaffanke, J.
    Celik, A.
    Wegener, H. P.
    Shah, N. J.
    JOURNAL OF MAGNETIC RESONANCE, 2006, 181 (02) : 203 - 211
  • [23] Optimization and Characterization of Sodium MRI Using 8-channel 23Na and 2-channel 1H RX/TX Coil
    James, J. R.
    Lin, C.
    Stark, H.
    Dale, B. M.
    Bansal, N.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 138 - +
  • [24] Iterative 3D Projection Reconstruction of 23Na Data with an 1H MRI Constraint
    Gnahm, Christine
    Bock, Michael
    Bachert, Peter
    Semmler, Wolfhard
    Behl, Nicolas G. R.
    Nagel, Armin M.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1720 - 1732
  • [25] Direct, longitudinal comparison of 1H and 23Na MRI after transient focal cerebral ischemia
    Lin, SP
    Song, SK
    Miller, JP
    Ackerman, JJH
    Neil, JJ
    STROKE, 2001, 32 (04) : 925 - 932
  • [26] Detection and identification of corrosion products of sodium aluminoborosilicate glasses by 23Na MQMAS and 1H → 23Na CPMAS NMR
    Egan, JM
    Mueller, KT
    JOURNAL OF PHYSICAL CHEMISTRY B, 2000, 104 (41): : 9580 - 9586
  • [27] Compressed sensing reconstruction of 7 Tesla 23Na multi-channel breast data using 1H MRI constraint
    Lachner, Sebastian
    Zaric, Olgica
    Utzschneider, Matthias
    Minarikova, Lenka
    Zbyn, Stefan
    Hensel, Bernhard
    Trattnig, Siegfried
    Uder, Michael
    Nagel, Armin M.
    MAGNETIC RESONANCE IMAGING, 2019, 60 : 145 - 156
  • [28] A metamaterial based dual-resonant coil element for combined sodium/hydrogen MRI at 7 Tesla
    Svejda, Jan Taro
    Rennings, Andreas
    Erni, Daniel
    TM-TECHNISCHES MESSEN, 2017, 84 (01) : 2 - 12
  • [29] Design and simulation of a dual-tuned 1H/23Na birdcage coil for MRS studies in human calf
    Giovannetti, Giulio
    Valvano, Giuseppe
    Virgili, Giorgio
    Giannoni, Massimo
    Flori, Alessandra
    Frijia, Francesca
    De Marchi, Daniele
    Hartwig, Valentina
    Landini, Luigi
    Aquaro, Giovanni Donato
    Pingitore, Alessandro
    APPLIED MAGNETIC RESONANCE, 2015, 46 (11) : 1221 - 1238
  • [30] Design and simulation of a dual-tuned 1H/23Na birdcage coil for MRS studies in human calf
    Giulio Giovannetti
    Giuseppe Valvano
    Giorgio Virgili
    Massimo Giannoni
    Alessandra Flori
    Francesca Frijia
    Daniele De Marchi
    Valentina Hartwig
    Luigi Landini
    Giovanni Donato Aquaro
    Alessandro Pingitore
    Applied Magnetic Resonance, 2015, 46 : 1221 - 1238