Projection Correlation Based Noise Reduction in Volume CT

被引:0
作者
Yan, Hao [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Image Proc & Pattern Recognit, Xian 710049, Peoples R China
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
De-noising algorithms for volume CT are proposed based on the correlation of the cone beam (CB) CT projections. The main idea is: when the correlated pixels among the neighboring views are added together according to this projection correlation (PC), the signal will be retained, whereas the noise variance upon them will be reduced by this averaging process, because the signal obeys this correlation but noise not. PC based filtering (PCF) method is developed. PCF is further integrated as PC based penalty weighted least square (PC-PWLS) method. Validations are performed for two volume scans: one is ideal low-dose case, and the other considers the high-frequency scatter residues after scatter correction. By using the proposed methods, significant noise suppressing is illustrated; meanwhile, the spatial resolution can be well preserved. For the low dose scan, SNR (Signal to Noise Ratio) increases are around 14 dB. For the cone beam scan with high frequency scatter residues, an effect approaching to the fan-beam scan is achieved.
引用
收藏
页码:2948 / 2953
页数:6
相关论文
共 7 条
  • [1] Kawrakow I., 2005, PIRS899 NRCC
  • [2] Tang S., 2009, 10 INT M FULL 3 DIM, P381
  • [3] An experimental study on the noise properties of x-ray CT sinogram data in Radon space
    Wang, Jing
    Lu, Hongbing
    Liang, Zhengrong
    Eremina, Daria
    Zhang, Guangxiang
    Wang, Su
    Chen, John
    Manzione, James
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (12) : 3327 - 3341
  • [4] Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    Wang, Jing
    Li, Tianfang
    Lu, Hongbing
    Liang, Zhengrong
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (10) : 1272 - 1283
  • [5] Projection correlation based view interpolation for cone beam CT: primary fluence restoration in scatter measurement with a moving beam stop array
    Yan, Hao
    Mou, Xuanqin
    Tang, Shaojie
    Xu, Qiong
    Zankl, Maria
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (21) : 6353 - 6375
  • [6] Noise suppression in scatter correction for cone-beam CT
    Zhu, Lei
    Wang, Jing
    Xing, Lei
    [J]. MEDICAL PHYSICS, 2009, 36 (03) : 741 - 752
  • [7] COMPUTERIZED 3-DIMENSIONAL SEGMENTED HUMAN ANATOMY
    ZUBAL, IG
    HARRELL, CR
    SMITH, EO
    RATTNER, Z
    GINDI, G
    HOFFER, PB
    [J]. MEDICAL PHYSICS, 1994, 21 (02) : 299 - 302