An adaptive scheme for parallel-line distance protection

被引:0
|
作者
Hu, Y [1 ]
Novosel, D
Saha, MM
Leitloff, V
机构
[1] ABB Elect Syst Technol Inst, Raleigh, NC 27606 USA
[2] ABB Automat Prod AB, S-72171 Vasteras, Sweden
[3] EDF DER, F-92141 Clamart, France
关键词
adaptive systems; coupled transmission lines; distance measurement; mutual coupling; protective relaying;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes an adaptive protective relaying scheme for parallel-line distance protection. The scheme adjusts its operation based on the availability of input signals to achieve an optimal distance protection performance on parallel lines influenced by mutual coupling effect. When available, zero sequence current from the parallel line is used to fully compensate the mutual coupling effect. The zero sequence current ratio is used to avoid possible false operations on healthy lines, which may result from such compensation. When the parallel line's zero sequence current is not available, the line operating status is used instead to select the proper zero sequence current compensation factors in impedance calculation. Default zero sequence current compensation factor is used when both the parallel line's zero sequence current and line operating status signals are not available. The performance of the scheme has been verified on a simulated network and the results are presented.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 50 条
  • [1] An adaptive scheme for parallel-line distance protection
    Hu, Yi
    Novosel, Damir
    Saha, Murari Mohan
    Leitloff, Volker
    2002, Institute of Electrical and Electronics Engineers Inc. (17)
  • [2] Improving parallel line distance protection with adaptive techniques
    Hu, Y
    Novosel, D
    Saha, MM
    Leitloff, V
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 1973 - 1978
  • [3] A New Adaptive Distance Protection Scheme for a Transmission Line
    Ma, Jing
    Yan, Xin
    Ma, Wei
    Sun, Lvyi
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (01) : 1 - 17
  • [4] Adaptive Distance Protection Scheme for Mutually Coupled Line
    Uma, Uma Uzubi
    Ekwue, Arthur
    Ejiogu, Emenike
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2021, 16 (01) : 131 - 140
  • [5] An adaptive distance scheme for double circuit line protection
    Sharifzadeh, M.
    Sanaye-Pasand, M.
    2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 310 - 315
  • [6] Adaptive Distance Protection Scheme for Mutually Coupled Line
    Uma Uzubi Uma
    Arthur Ekwue
    Emenike Ejiogu
    Journal of Electrical Engineering & Technology, 2021, 16 : 131 - 140
  • [7] An improved adaptive distance protection scheme for the outgoing line of PV power station
    Wang F.
    Fang Y.
    Zhao P.
    Zheng Y.
    Zhou Z.
    Zheng T.
    Wang M.
    Huang Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (20): : 127 - 134
  • [8] PARALLEL-LINE NETWORK AS MATCHING NETWORK
    DEBUDA, RG
    IEEE TRANSACTIONS ON CIRCUIT THEORY, 1963, CT10 (02): : 201 - &
  • [9] APPLICATION OF THE BUFFON NEEDLE PROBLEM AND ITS EXTENSIONS TO PARALLEL-LINE SEARCH SAMPLING SCHEME
    CHUNG, CF
    JOURNAL OF THE INTERNATIONAL ASSOCIATION FOR MATHEMATICAL GEOLOGY, 1981, 13 (05): : 371 - 390
  • [10] Development of Three Zone Quadrilateral Adaptive Distance Relay for the Protection of Parallel Transmission line
    Srivani, S. G.
    Panduranga, Vittal K.
    Atla, Chandrasekhar Reddy
    2009 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-3, 2009, : 324 - 329