Enhanced ventricular tachycardia substrate resolution with a novel omnipolar high-density mapping catheter: the omnimapping study

被引:17
作者
Proietti, Riccardo [1 ]
Adlan, Ahmed M. [2 ]
Dowd, Rory [2 ]
Assadullah, Shershah [2 ]
Aldhoon, Bashar [2 ,3 ]
Panikker, Sandeep [2 ]
Foster, Will [2 ,3 ]
Yusuf, Shamil [2 ,4 ]
Hayat, Sajad [2 ]
Osman, Faizel [2 ,5 ]
Banerjee, Prithwish [2 ,5 ]
Dhanjal, Tarvinder [2 ,5 ]
机构
[1] Univ Padua, Dept Cardiac Thorac Vasc Sci, Padua, Italy
[2] Coventry & Warwickshire NHS Trust, Univ Hosp, Univ Hosp Coventry, Dept Cardiol, Clifford Bridge Rd, Coventry, W Midlands, England
[3] Worcestershire Acute Hosp NHS Trust, Worcestershire Royal Hosp, Dept Cardiol, Charles Hastings Way, Worcester, MA USA
[4] Univ Hosp Birmingham NHS Fdn Trust, Good Hope Hosp, Dept Cardiol, Rectory Rd, Sutton B75 7RR, Coldfield, England
[5] Univ Warwick, Med Sch, Coventry CV4 7AJ, W Midlands, England
关键词
Ventricular tachycardia; Substrate ablation; Substrate mapping; Mapping catheters; Omnipolar high-density mapping catheter; ABLATION; IMPACT; CARDIOMYOPATHY; DISEASE; SITES; HEART; SCAR;
D O I
10.1007/s10840-019-00625-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Defining diastolic slow-conduction channels within the borderzone (BZ) of scar-dependent re-entrant ventricular tachycardia (VT) is key for effective mapping and ablation strategies. Understanding wavefront propagation is driving advances in high-density (HD) mapping. The newly developed Advisor (TM) HD Grid Mapping Catheter (HD GRID) has equidistant spacing of 16, 1 mm electrodes in a 4 x 4 3 mm interspaced arrangement allowing bipolar recordings along and uniquely across the splines (orthogonal vector) to facilitate substrate mapping in a WAVE configuration (WAVE). The purpose of this study was to determine the relative importance of the WAVE configuration compared to the STANDARD linear-only bipolar configuration (STANDARD) in defining VT substrate. Methods Thirteen patients underwent VT ablation at our institution. In all cases, a substrate map was constructed with the HD GRID in the WAVE configuration (conWAVE) to guide ablation strategy. At the end of the procedure, the voltage map was remapped in the STANDARD configuration (conSTANDARD) using the turbo-map function. Detailed post-hoc analysis of the WAVE and STANDARD maps was performed blinded to the configuration. Quantification of total scar area, BZ and dense scar area with assessment of conduction channels (CC) was performed. Results The substrate maps conSTANDARD vs conWAVE showed statistically significant differences in the total scar area (56 +/- 32 cm(2)vs 51 +/- 30 cm(2);p = 0.035), dense scar area (36 +/- 25 cm(2)vs 29 +/- 22 cm(2);p = 0.002) and number of CC (3.3 +/- 1.6 vs 4.8 +/- 2.5;p = 0.026). conWAVE collected more points than the conSTANDARD settings (p = 0.001); however, it used fewer points in map construction (p = 0.023). Conclusions The multipolar Advisor (TM) HD Grid Mapping Catheter in conWAVE provides more efficient point acquisition and greater VT substrate definition of the borderzone particularly at the low-voltage range compared to conSTANDARD. This greater resolution within the low-voltage range facilitated CC definition and quantification within the scar, which is essential in guiding the ablation strategy.
引用
收藏
页码:355 / 362
页数:8
相关论文
共 50 条
  • [41] Utility of high density multielectrode mapping during ablation of scar-related ventricular tachycardia
    Cano, Oscar
    Plaza, Diego
    Sauri, Assumpcio
    Osca, Joaquin
    Alonso, Pau
    Andres, Ana
    Sancho-Tello, Maria-Jose
    Martinez-Dolz, Luis
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (11) : 1306 - 1315
  • [42] Substrate Mapping for Ventricular Tachycardia Ablation Through High-Density Whole-Chamber Double Extra Stimuli The S3 Protocol
    Guichard, Jean-Baptiste
    Regany-Closa, Mariona
    Vazquez-Calvo, Sara
    Zazu, Blanca
    Sendra, Berta Pellicer
    Serrano-Campaner, Jaume
    Molero-Pereira, Silvia
    Borras, Roger
    Ortiz, Jose Tomas
    Falzone, Pasquale Valerio
    Eulogio, Frida
    Reventos-Presmanes, Jana
    Garre, Paz
    Arbelo, Elena
    Althoff, Till F.
    Guasch, Eduard
    Tolosana, Jose Maria
    Brugada, Josep
    Mont, Lluis
    Porta-Sanchez, Andreu
    Roca-Luque, Ivo
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2024, 10 (07) : 1534 - 1547
  • [43] Evaluation of a novel high-resolution mapping system for catheter ablation of ventricular arrhythmias
    Viswanathan, Karthik
    Mantziari, Lilian
    Butcher, Charles
    Hodkinson, Emily
    Lim, Eric
    Khan, Habib
    Panikker, Sandeep
    Haldar, Shouvik
    Jarman, Julian W. E.
    Jones, David G.
    Hussain, Wajid
    Foran, John P.
    Markides, Vias
    Wong, Tom
    HEART RHYTHM, 2017, 14 (02) : 176 - 183
  • [44] Impact of different activation wavefronts on ischemic myocardial scar electrophysiological properties during high-density ventricular tachycardia mapping and ablation
    Da Silva, Gustavo Lima
    Cortez-Dias, Nuno
    Nunes Ferreira, Afonso
    Nakar, Elad
    Francisco, Raquel
    Pereira, Mariana
    Moreno, Javier
    Martins, Raphaeal P.
    Pinto, Fausto J. J.
    De Sousa, Joao
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (02) : 389 - 399
  • [45] High-density electroanatomic mapping with grid catheter in pediatrics and congenital heart disease
    von Alvensleben, Johannes C.
    Sandhu, Amneet
    Chang, Shu
    Runciman, D. Martin
    Wehrmann, Melissa
    Tzou, D. Wendy
    Schafer, Michal
    Collins, Kathryn K.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (03) : 611 - 619
  • [46] High-Resolution Optical Mapping of Ventricular Tachycardia in Rats with Chronic Myocardial Infarction
    Ding, Chunhua
    Gepstein, Lior
    Duy Thai Nguyen
    Wilson, Emily
    Hulley, George
    Beaser, Andrew
    Lee, Randall J.
    Olgin, Jeffrey
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (06): : 687 - 695
  • [47] High-Resolution Mapping of Postinfarction Reentrant Ventricular Tachycardia Electrophysiological Characterization of the Circuit
    Anter, Elad
    Tschabrunn, Cory M.
    Buxton, Alfred E.
    Josephson, Mark E.
    CIRCULATION, 2016, 134 (04) : 314 - +
  • [48] High-density mapping of a single-loop biatrial macroreentrant tachycardia
    Solimene, Francesco
    Maddaluno, Francesco
    Schillaci, Vincenzo
    Urraro, Francesco
    HEART RHYTHM, 2018, 15 (05) : 792 - 792
  • [49] Impact of a high-density grid catheter on long-term outcomes for structural heart disease ventricular tachycardia ablation
    Proietti, Riccardo
    Dowd, Rory
    Gee, Lim Ven
    Yusuf, Shamil
    Panikker, Sandeep
    Hayat, Sajad
    Osman, Faizel
    Patel, Kiran
    Salim, Handi
    Aldhoon, Bashar
    Foster, Will
    Merghani, Ahmed
    Kuehl, Michael
    Banerjee, Prithwish
    Lellouche, Nicolas
    Dhanjal, Tarvinder
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (03) : 519 - 529
  • [50] Utility of directional high-density mapping catheter (AdvisorTM HD Grid) in complex scar-related atrial tachycardia
    Tan, Vern Hsen
    Lyu, Murphy Zhiyuan
    Tan, Peter Carlo
    Wong, Loo Chin
    Yeo, Colin
    Wong, Kelvin Cheok Keng
    JOURNAL OF ARRHYTHMIA, 2020, 36 (01) : 180 - 183