Watchman FLX vs. Watchman 2.5 in a Dual-Center Left Atrial Appendage Closure Cohort: the WATCH-DUAL study

被引:29
|
作者
Galea, Roberto [1 ]
Mahmoudi, Khalil [2 ]
Grani, Christoph [1 ]
Elhadad, Simon [2 ,3 ]
Huber, Adrian T. [1 ]
Heg, Dik [4 ]
Siontis, George C. M. [1 ]
Brugger, Nicolas [1 ]
Sebag, Frederic [2 ]
Windecker, Stephan [1 ]
Valgimigli, Marco [1 ,5 ]
Landolff, Quentin [2 ]
Roten, Laurent [1 ]
Amabile, Nicolas [2 ]
Raber, Lorenz [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Cardiol, Inselspital, CH-3010 Bern, Switzerland
[2] Inst Mutualiste Montsouris, Dept Cardiol, Paris, France
[3] Cardiol Dept, Jossigny, France
[4] Univ Bern, Clin Trials Unit, Bern, Switzerland
[5] Inst & Univ Svizzera Italiana USI, Cardioctr Ticino, Lugano, Switzerland
来源
EUROPACE | 2022年 / 24卷 / 09期
关键词
Left atrial appendage closure; Watchman; 2; 5; Watchman FLX; Cardiac computed tomography angiography; Device-related thrombus; Device permeability; OCCLUSION; ECHOCARDIOGRAPHY; FIBRILLATION; SAFETY;
D O I
10.1093/europace/euac021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims No studies have compared Watchman 2.5 (W2.5) with Watchman FLX (FLX) devices to date. We aimed at comparing the FLX with W2.5 devices with respect to clinical outcomes, left atrial appendage (LAA) sealing properties and device-related thrombus (DRT). Methods and results All consecutive left atrial appendage closure (LAAC) procedures performed at two European centres between November 2017 and February 2021 were included. Procedure-related complications and net adverse cardiovascular events (NACE) at 6 months after LAAC were recorded. At 45-day computed tomography (CT) follow-up, intra- (IDL) and peri- (PDL) device leak, residual patent neck area (RPNA), and DRT were assessed by a Corelab. Out of 144 LAAC consecutive procedures, 71 and 73 interventions were performed using W2.5 and FLX devices, respectively. There were no differences in terms of procedure-related complications (4.2% vs. 2.7%, P = 0.626). At 45-day CT, the FLX was associated with lower frequency of IDL [21.3% vs. 40.0%; P = 0.032; odds ratio (OR): 0.375; 95% confidence interval (CI): 0.160-0.876; P = 0.024], similar rate of PDL (29.5% vs. 42.0%; P = 0.170), and smaller RPNA [6 (0-36) vs. 40 (6-115) mm(2); P = 0.001; OR: 0.240; 95% CI: 0.100-0.577; P = 0.001] compared with the W2.5 group. At 45 days, rate of DRT as detected by CT and/or transoesophageal echocardiography (TOE), was higher with W2.5 (6.0% vs. 0%, P = 0.045). At 6-month follow-up, NACE did not differ between groups. Conclusions In this cohort of consecutive LAACs, FLX as compared to W2.5, was associated with similar procedure-related complications and 6-month NACE, but with improved LAA neck coverage, and lower IDL and DRT.
引用
收藏
页码:1441 / 1450
页数:10
相关论文
共 49 条
  • [41] Percutaneous closure of a 'whale tail' left atrial appendage with a Watchman FLX device and pre-procedural FEops HEARTguide patient-specific computational simulation: a case report
    Di Muro, Francesca Maria
    Stolcova, Miroslava
    Di Mario, Carlo
    Meucci, Francesco
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2022, 6 (05)
  • [42] Clinical efficacy and safety comparison of Watchman device versus ACP/Amulet device for percutaneous left atrial appendage closure in patients with nonvalvular atrial fibrillation: A study-level meta-analysis of clinical trials
    Bing, Sun
    Chen, Rui Rui
    CLINICAL CARDIOLOGY, 2023, 46 (02) : 117 - 125
  • [43] Efficacy and Safety of the WATCHMAN Left Atrial Appendage System for Stroke Prevention in Chinese Patients with Nonvalvular Atrial Fibrillation: A Single-center, Prospective, Observational Study
    Huang Wei-Ping
    Zhang Yong-Hua
    He Lei
    Su Xi
    Yang Xin-Wei
    Guo Zai-Xiong
    中华医学杂志英文版, 2017, 130 (04) : 434 - 438
  • [44] Efficacy and Safety of the WATCHMAN Left Atrial Appendage System for Stroke Prevention in Chinese Patients with Nonvalvular Atrial Fibrillation: A Single-center, Prospective, Observational Study
    Huang, Wei-Ping
    Zhang, Yong-Hua
    He, Lei
    Su, Xi
    Yang, Xin-Wei
    Guo, Zai-Xiong
    CHINESE MEDICAL JOURNAL, 2017, 130 (04) : 434 - 438
  • [45] Safety and efficacy of percutaneous Watchman 2.5 device versus Amplatzer Amulet for left atrial appendage closure in patients with non-valvular atrial fibrillation: A systematic review and study-level meta-analysis
    Yasmin, Farah
    Ali, Eman
    Moeed, Abdul
    Zaidi, Farwa
    Umar, Muhammad
    Virwani, Vikash
    PLOS ONE, 2024, 19 (02):
  • [46] A Pilot Study of Monotherapy with a Non-Vitamin K-Antagonist Oral Anticoagulant following Watchman Left Atrial Appendage Closure in Patients with Non-Valvular Atrial Fibrillation
    Price, Matthew J.
    Lerner, David
    Rastogi, Ashish
    Romero, Steven
    Smith, Michael R.
    Rubenson, David
    Funk, Jessica
    Janzcyk, Gwen
    Edwards-Mobley, Monique
    Wheeler, Carmen
    Gibson, Douglas
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2020, 4 (04): : 288 - 292
  • [47] Reduced direct oral anticoagulant dose vs dual antiplatelet therapy after left atrial appendage closure in patients with nonvalvular atrial fibrillation: A systematic review and meta-analysis
    Lima, Nagila A.
    Filho, Francisco W. P. A.
    Mendes, Beatriz X.
    Neto, Vicente L. M.
    d'Avila, Andre L. B.
    HEART RHYTHM, 2025, 22 (04) : 979 - 986
  • [48] Reduced Rivaroxaban Dose Versus Dual Antiplatelet Therapy After Left Atrial Appendage Closure ADRIFT a Randomized Pilot Study
    Duthoit, Guillaume
    Silvain, Johanne
    Marijon, Eloi
    Ducrocq, Gregory
    Lepillier, Antoine
    Frere, Corinne
    Dimby, Solohaja-Faniaha
    Popovic, Batric
    Lellouche, Nicolas
    Martin-Toutain, Isabelle
    Spaulding, Christian
    Brochet, Eric
    Attias, David
    Mansourati, Jacques
    Lorgis, Luc
    Klug, Didier
    Zannad, Noura
    Hauguel-Moreau, Marie
    Braik, Nassim
    Deltour, Sandrine
    Ceccaldi, Alexandre
    Wang, Hui
    Hammoudi, Nadjib
    Brugier, Delphine
    Vicaut, Eric
    Juliard, Jean-Michel
    Montalescot, Gilles
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (07)
  • [49] Clinical Effectiveness and Safety Comparison between Reduced Rivaroxaban Dose and Dual Antiplatelet Therapy for Nonvalvular Atrial Fibrillation Patients Following Percutaneous Left Atrial Appendage Closure: A Prospective Observational Study
    Li, Xiaoye
    Jin, Qinchun
    Yao, Yao
    Zhang, Xiaochun
    Lv, Qianzhou
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (11)