Watchman FLX vs. Watchman 2.5 in a Dual-Center Left Atrial Appendage Closure Cohort: the WATCH-DUAL study

被引:29
|
作者
Galea, Roberto [1 ]
Mahmoudi, Khalil [2 ]
Grani, Christoph [1 ]
Elhadad, Simon [2 ,3 ]
Huber, Adrian T. [1 ]
Heg, Dik [4 ]
Siontis, George C. M. [1 ]
Brugger, Nicolas [1 ]
Sebag, Frederic [2 ]
Windecker, Stephan [1 ]
Valgimigli, Marco [1 ,5 ]
Landolff, Quentin [2 ]
Roten, Laurent [1 ]
Amabile, Nicolas [2 ]
Raber, Lorenz [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Cardiol, Inselspital, CH-3010 Bern, Switzerland
[2] Inst Mutualiste Montsouris, Dept Cardiol, Paris, France
[3] Cardiol Dept, Jossigny, France
[4] Univ Bern, Clin Trials Unit, Bern, Switzerland
[5] Inst & Univ Svizzera Italiana USI, Cardioctr Ticino, Lugano, Switzerland
来源
EUROPACE | 2022年 / 24卷 / 09期
关键词
Left atrial appendage closure; Watchman; 2; 5; Watchman FLX; Cardiac computed tomography angiography; Device-related thrombus; Device permeability; OCCLUSION; ECHOCARDIOGRAPHY; FIBRILLATION; SAFETY;
D O I
10.1093/europace/euac021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims No studies have compared Watchman 2.5 (W2.5) with Watchman FLX (FLX) devices to date. We aimed at comparing the FLX with W2.5 devices with respect to clinical outcomes, left atrial appendage (LAA) sealing properties and device-related thrombus (DRT). Methods and results All consecutive left atrial appendage closure (LAAC) procedures performed at two European centres between November 2017 and February 2021 were included. Procedure-related complications and net adverse cardiovascular events (NACE) at 6 months after LAAC were recorded. At 45-day computed tomography (CT) follow-up, intra- (IDL) and peri- (PDL) device leak, residual patent neck area (RPNA), and DRT were assessed by a Corelab. Out of 144 LAAC consecutive procedures, 71 and 73 interventions were performed using W2.5 and FLX devices, respectively. There were no differences in terms of procedure-related complications (4.2% vs. 2.7%, P = 0.626). At 45-day CT, the FLX was associated with lower frequency of IDL [21.3% vs. 40.0%; P = 0.032; odds ratio (OR): 0.375; 95% confidence interval (CI): 0.160-0.876; P = 0.024], similar rate of PDL (29.5% vs. 42.0%; P = 0.170), and smaller RPNA [6 (0-36) vs. 40 (6-115) mm(2); P = 0.001; OR: 0.240; 95% CI: 0.100-0.577; P = 0.001] compared with the W2.5 group. At 45 days, rate of DRT as detected by CT and/or transoesophageal echocardiography (TOE), was higher with W2.5 (6.0% vs. 0%, P = 0.045). At 6-month follow-up, NACE did not differ between groups. Conclusions In this cohort of consecutive LAACs, FLX as compared to W2.5, was associated with similar procedure-related complications and 6-month NACE, but with improved LAA neck coverage, and lower IDL and DRT.
引用
收藏
页码:1441 / 1450
页数:10
相关论文
共 49 条
  • [21] Caged-in: Successful percutaneous closure of left atrial appendage with Watchman-FLX in the presence of proximal thrombus
    Gala, Andre Briosa e
    Pope, Michael T. B.
    Newton, James D.
    Dawkins, Sam
    Betts, Timothy R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (06) : 1655 - 1657
  • [22] Feasibility of contrast-free left atrial appendage closure with WATCHMAN FLX device for patients with chronic kidney disease
    Okada, Azusa
    Kubo, Shunsuke
    Chatani, Ryuki
    Mushiake, Kazunori
    Nishiura, Naoki
    Ono, Sachiyo
    Maruo, Takeshi
    Kadota, Kazushige
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2024, 39 (02) : 191 - 199
  • [23] Left atrial appendage closure with the Watchman device using intracardiac vs transesophageal echocardiography: Procedural and cost considerations
    Hemam, Majd E.
    Kuroki, Kenji
    Schurmann, Paul A.
    Dave, Amish S.
    Rodriguez, Diego A.
    Saenz, Luis C.
    Reddy, Vivek Y.
    Valderrabano, Miguel
    HEART RHYTHM, 2019, 16 (03) : 334 - 342
  • [24] First-in-human left atrial appendage closure using the WATCHMAN FLX Pro device: a case report
    Nielsen-Kudsk, Jens Erik
    Kramer, Anders
    Andersen, Asger
    Kim, Won Yong
    Korsholm, Kasper
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2024, 8 (04)
  • [25] Design and Rationale of the Swiss-Apero Randomized Clinical Trial: Comparison of Amplatzer Amulet vs Watchman Device in Patients Undergoing Left Atrial Appendage Closure
    Galea, Roberto
    De Marco, Federico
    Aminian, Adel
    Meneveau, Nicolas
    Anselme, Frederic
    Grani, Christoph
    Huber, Adrian T.
    Teiger, Emmanuel
    Iriart, Xavier
    Angelillis, Marco
    Brugger, Nicolas
    Spirito, Alessandro
    Corpataux, Noe
    Franzone, Anna
    Vranckx, Pascal
    Fischer, Urs
    Pedrazzini, Giovanni
    Bedogni, Francesco
    Windecker, Stephan
    Raber, Lorenz
    Valgimigli, Marco
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2021, 14 (05) : 930 - 940
  • [26] The Added Value of Preprocedural Cardiac Computed Tomography in Planning Left Atrial Appendage Closure With the Watchman FLX Device
    Kassab, Joseph
    Nakhla, Shady
    Miyasaka, Rhonda L.
    Saliba, Walid
    Ghobrial, Joanna
    Wazni, Oussama
    Kapadia, Samir R.
    Kanj, Mohamed
    Harb, Serge C.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2023, 7 (05):
  • [27] Left Atrial Appendage Closure With the Watchman Device Using Intracardiac vs. Transesophageal Echocardiography: Procedural and Cost Considerations
    Hemam, Majd
    Schurmann, Paul A.
    Dave, Amish S.
    Rodriguez, Diego A.
    Saenz, Luis C.
    Valderrabano, Miguel
    CIRCULATION, 2018, 138
  • [28] Feasibility of contrast-free left atrial appendage closure with WATCHMAN FLX device for patients with chronic kidney disease
    Azusa Okada
    Shunsuke Kubo
    Ryuki Chatani
    Kazunori Mushiake
    Naoki Nishiura
    Sachiyo Ono
    Takeshi Maruo
    Kazushige Kadota
    Cardiovascular Intervention and Therapeutics, 2024, 39 : 191 - 199
  • [29] Improved Left Atrial Appendage Closure With the New-Generation WATCHMAN FLX by Cardiac Computed Tomography Angiography at 45 Days Postimplant
    Ranard, Lauren S.
    Guber, Kenneth
    Khalique, Omar K.
    Leb, Jay
    Hamid, Nadira
    Donald, Elena
    Hahn, Rebecca T.
    Forman, Jessica
    Ng, Vivian
    Leon, Martin B.
    Sommer, Robert
    Vahl, Torsten P.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (04)
  • [30] WATCHMEN: a case report highlighting the closure of a bilobed left atrial appendage using two WATCHMAN-FLX devices
    Sood, Abhinav
    Kalavakunta, Jagadeesh K.
    Gourineni, Venu
    Gupta, Vishal
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2023, 7 (12)