Watchman FLX vs. Watchman 2.5 in a Dual-Center Left Atrial Appendage Closure Cohort: the WATCH-DUAL study

被引:29
|
作者
Galea, Roberto [1 ]
Mahmoudi, Khalil [2 ]
Grani, Christoph [1 ]
Elhadad, Simon [2 ,3 ]
Huber, Adrian T. [1 ]
Heg, Dik [4 ]
Siontis, George C. M. [1 ]
Brugger, Nicolas [1 ]
Sebag, Frederic [2 ]
Windecker, Stephan [1 ]
Valgimigli, Marco [1 ,5 ]
Landolff, Quentin [2 ]
Roten, Laurent [1 ]
Amabile, Nicolas [2 ]
Raber, Lorenz [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Cardiol, Inselspital, CH-3010 Bern, Switzerland
[2] Inst Mutualiste Montsouris, Dept Cardiol, Paris, France
[3] Cardiol Dept, Jossigny, France
[4] Univ Bern, Clin Trials Unit, Bern, Switzerland
[5] Inst & Univ Svizzera Italiana USI, Cardioctr Ticino, Lugano, Switzerland
来源
EUROPACE | 2022年 / 24卷 / 09期
关键词
Left atrial appendage closure; Watchman; 2; 5; Watchman FLX; Cardiac computed tomography angiography; Device-related thrombus; Device permeability; OCCLUSION; ECHOCARDIOGRAPHY; FIBRILLATION; SAFETY;
D O I
10.1093/europace/euac021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims No studies have compared Watchman 2.5 (W2.5) with Watchman FLX (FLX) devices to date. We aimed at comparing the FLX with W2.5 devices with respect to clinical outcomes, left atrial appendage (LAA) sealing properties and device-related thrombus (DRT). Methods and results All consecutive left atrial appendage closure (LAAC) procedures performed at two European centres between November 2017 and February 2021 were included. Procedure-related complications and net adverse cardiovascular events (NACE) at 6 months after LAAC were recorded. At 45-day computed tomography (CT) follow-up, intra- (IDL) and peri- (PDL) device leak, residual patent neck area (RPNA), and DRT were assessed by a Corelab. Out of 144 LAAC consecutive procedures, 71 and 73 interventions were performed using W2.5 and FLX devices, respectively. There were no differences in terms of procedure-related complications (4.2% vs. 2.7%, P = 0.626). At 45-day CT, the FLX was associated with lower frequency of IDL [21.3% vs. 40.0%; P = 0.032; odds ratio (OR): 0.375; 95% confidence interval (CI): 0.160-0.876; P = 0.024], similar rate of PDL (29.5% vs. 42.0%; P = 0.170), and smaller RPNA [6 (0-36) vs. 40 (6-115) mm(2); P = 0.001; OR: 0.240; 95% CI: 0.100-0.577; P = 0.001] compared with the W2.5 group. At 45 days, rate of DRT as detected by CT and/or transoesophageal echocardiography (TOE), was higher with W2.5 (6.0% vs. 0%, P = 0.045). At 6-month follow-up, NACE did not differ between groups. Conclusions In this cohort of consecutive LAACs, FLX as compared to W2.5, was associated with similar procedure-related complications and 6-month NACE, but with improved LAA neck coverage, and lower IDL and DRT.
引用
收藏
页码:1441 / 1450
页数:10
相关论文
共 49 条
  • [1] Clinical outcomes of Watchman vs. Amplatzer occluders for left atrial appendage closure (WATCH at LAAC)
    Kleinecke, Caroline
    Yu, Jiangtao
    Neef, Philip
    Buffle, Eric
    de Marchi, Stefano
    Fuerholz, Monika
    Nietlispach, Fabian
    Valgimigli, Marco
    Streit, Samuel R.
    Fankhauser, Mate
    Duenninger, Erich
    Windecker, Stephan
    Meier, Bernhard
    Gloekler, Steffen
    EUROPACE, 2020, 22 (06): : 916 - 923
  • [2] Watchman vs. Amulet for Left Atrial Appendage Closure: Current Evidence and Future Perspectives
    Frazzetto, Marco
    Sanfilippo, Claudio
    Costa, Giuliano
    Contrafatto, Claudia
    Giacalone, Chiara
    Scandura, Salvatore
    Castania, Giuseppe
    De Santis, Jessica
    Sanfilippo, Maria
    Di Salvo, Maria Elena
    Tamburino, Corrado
    Barbanti, Marco
    Grasso, Carmelo
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (16)
  • [3] Combined atrial fibrillation ablation and left atrial appendage closure: Watchman vs. LAmbre devices
    Ke, Jin-Yan
    Jin, Lu-Shen
    Lin, Yuan-Nan
    Xu, Jing
    Liu, Wei-Ke
    Fu, Jia-Yang
    Li, Ling
    Chen, Yi-Lian
    Qiu, Yi-Xuan
    Li, Yue-Chun
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [4] Left Atrial Appendage Closure with Watchman vs Amulet Devices: Similarities and Differences
    Ahmed, Adnan
    Bawa, Danish
    Kabra, Rajesh
    Pothineni, Naga Venkata K.
    Darden, Douglas
    Gopinathannair, Rakesh
    Lakkireddy, Dhanunjaya
    CURRENT CARDIOLOGY REPORTS, 2023, 25 (9) : 909 - 915
  • [5] Transition from WATCHMAN V.2.5 to WATCHMAN FLX for closure of the left atrial appendage: echocardiographic and clinical findings
    Sakriss, Charlotte
    Roehl, Peter
    Schwenzky, Andreas
    Hoyme, Matthias
    Ebelt, Henning
    OPEN HEART, 2023, 10 (01):
  • [6] Left Atrial Appendage Closure with the Watchman FLX System in a Patient with Hypertrophic Cardiomy
    Funaki, Takashi
    Saji, Mike
    Terada, Mai
    Takamisawa, Itaru
    Nanasato, Mamoru
    Nagao, Takehiko
    Ikeda, Takanori
    Isobe, Mitsuaki
    INTERNAL MEDICINE, 2024, 63 (03) : 399 - 402
  • [7] Bailout Additional Watchman FLX Device Implantation for Left Atrial Appendage Closure
    Frazzetto, Marco
    Costa, Giuliano
    Scandura, Salvatore
    Tamburino, Corrado
    Grasso, Carmelo
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 40 : 208 - 209
  • [8] Comparative Data of Procedural and Midterm Outcomes in Patients Who Underwent Percutaneous Left Atrial Appendage Closure Between the WATCHMAN FLX and WATCHMAN 2.5 Devices - Insight From the OCEAN-LAAC Registry -
    Nakashima, Masaki
    Yamamoto, Masanori
    Sago, Mitsuru
    Tanaka, Shuhei
    Chatani, Ryuki
    Asami, Masahiko
    Hachinohe, Daisuke
    Naganuma, Toru
    Ohno, Yohei
    Tani, Tomoyuki
    Okamatsu, Hideharu
    Mizutani, Kazuki
    Watanabe, Yusuke
    Izumo, Masaki
    Saji, Mike
    Mizuno, Shingo
    Ueno, Hiroshi
    Kubo, Shunsuke
    Shirai, Shinichi
    Hayashida, Kentaro
    CIRCULATION JOURNAL, 2024, 88 (07) : 1187 - 1197
  • [9] Dual device closure of a bilobar left atrial appendage with a plug (Watchman 2.5™ 30 mm) and a pacifier (Amulet™ 20 mm) device
    Noutsias, Michel
    Melnyk, Hannes
    Ali, Muhammad
    Daehnert, Ingo
    Empen, Klaus
    Sedding, Daniel
    Rigopoulos, Angelos G.
    HELLENIC JOURNAL OF CARDIOLOGY, 2021, 62 (01) : 81 - 83
  • [10] Left Atrial Appendage Closure with Watchman vs Amulet Devices: Similarities and Differences
    Adnan Ahmed
    Danish Bawa
    Rajesh Kabra
    Naga Venkata K. Pothineni
    Douglas Darden
    Rakesh Gopinathannair
    Dhanunjaya Lakkireddy
    Current Cardiology Reports, 2023, 25 : 909 - 915