Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty Surgery

被引:413
作者
Mason, J. Bohannon [1 ]
Fehring, Thomas K. [1 ]
Estok, Rhonda [2 ]
Banel, Deirdre
Fahrbach, Kyle [2 ]
机构
[1] OrthoCarolina, Charlotte, NC 28207 USA
[2] BioSource Inc, Medford, MA USA
关键词
computer-assisted surgery; meta-analysis; alignment;
D O I
10.1016/j.arth.2007.08.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computer-assisted surgery (CAS) has been advocated as a means to improve limb and prosthesis alignment and assist in ligament balancing in total knee arthroplasty (TKA). Thus, We Sought to examine alignment outcomes in CAS vs conventional TKA. A systematic review of literature from 1990 to 2007 was performed. Direct comparison of alignment outcomes was performed using random effects meta-analyses. Twenty-nine studies of CAS vs conventional TKA were identified, and included mechanical axis malalignment of greater than 3 degrees occurred in 9.0% of CAS vs 31.8% of conventional TKA patients. The risk of greater than 3 degrees malalignment was significantly less with CAS than conventional techniques for mechanical axis and frontal plane femoral and tibial component alignment. Tibial and femoral slope both showed statistical significance in favor of CAS at greater than 2 degrees malalignment. Meta-analysis of alignment outcomes for CAS vs conventional TKA indicates significant improvement in component orientation and mechanical axis when CAS is used.
引用
收藏
页码:1097 / 1106
页数:10
相关论文
共 44 条
[11]  
Centers for Disease Control and Prevention (CDC), 2003, MMWR Morb Mortal Wkly Rep, V52, P489
[12]   Kinematic navigation in total knee replacement - Experience from the first 50 cases [J].
Chang, Chih-Wei ;
Yang, Chyun-Yu .
JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2006, 105 (06) :468-474
[13]   Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[14]   Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique [J].
Chin, PL ;
Yang, KY ;
Yeo, SJ ;
Lo, NN .
JOURNAL OF ARTHROPLASTY, 2005, 20 (05) :618-626
[15]  
Confalonieri Norberto, 2005, Acta Orthop Belg, V71, P703
[16]   Systematic reviews: Synthesis of best evidence for clinical decisions [J].
Cook, DJ ;
Mulrow, CD ;
Haynes, RB .
ANNALS OF INTERNAL MEDICINE, 1997, 126 (05) :376-380
[17]  
Daubresse Francois, 2005, Acta Orthop Belg, V71, P710
[18]   Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation [J].
Decking, R ;
Markmann, Y ;
Fuchs, J ;
Puhl, W ;
Scharf, HP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :282-288
[19]  
Delp SL, 1998, CLIN ORTHOP RELAT R, P49
[20]   METAANALYSIS IN CLINICAL-TRIALS [J].
DERSIMONIAN, R ;
LAIRD, N .
CONTROLLED CLINICAL TRIALS, 1986, 7 (03) :177-188