Experimental study on the characteristics of longitudinal fin air-heating vaporizers in different seasons

被引:34
作者
Jeong, Hyo Min [1 ]
Chung, Han Shik [1 ]
Djajadiwinata, Eldwin [2 ]
Kim, Pil Hwan [2 ]
Lee, Yong Hun
机构
[1] Gyeongsang Natl Univ, Sch Mech & Aerosp Engn, Inst Marine Ind, Gyeongsang Namdo 650160, South Korea
[2] Gyeongsang Natl Univ, Grad Sch, Dept Mech & Precis Engn, Gyeongsang Namdo 650160, South Korea
关键词
LNG (liquefied natural gas); LN2 (liquid nitrogen); vaporizer; fin; super low temperature;
D O I
10.1007/s12206-007-1216-1
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Air-heating vaporizers are usually used to regasify LNG at satellite areas because of the small demand for natural gas there. The common type of air heating vaporizer which exists in the market is the longitudinally finned type with 8 fins, 50mm fin length and 2mm fin thickness. To contribute in developing an efficient air-heating vaporizer, experiment on finned type air-heating vaporizer using 8 fins, 50mm fin length with 2mm fin thickness (8fin501e) -which exist in the market- and 4 fins, 75mm fin length with 2mm fin thickness (4fin75le), which is proposed, were conducted. Then, both types of vaporizers are compared. The experiments were conducted in one hour by varying the ambient condition and the length of the vaporizer. The ambient air was controlled so that it has the same condition (same temperature, humidity and air velocity) with air condition in every season available and the length was varied 4000mm, 6000mm and 8000mm for each type of vaporizer. Additional experiment with longer duration, i.e., 4 hours and in a single room condition was conducted to validate the previous result. In this experiment, the main aspects in analyzing the characteristics of the air heating vaporizer are the inlet-outlet enthalpy difference and the outlet temperature of the working fluid. LN2 is used to substitute LNG for safety reasons. The results show that the characteristics of the finned type 4fin75le vaporizer are comparable to the finned type 8fin50le vaporizer.
引用
收藏
页码:981 / 990
页数:10
相关论文
共 13 条
[1]  
CHUNG BTF, 1998, P 11 IHTC 5 AUG 23 2
[2]  
Foss M.M., 2003, INTRO LNG OVERVIEW L
[3]   Optimum design of vaporizer fin with liquefied natural gas by numerical analysis [J].
Jeong, HM ;
Chung, HS ;
Lee, SC ;
Kong, TW ;
Yi, CS .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2006, 20 (04) :545-553
[4]  
KONG TW, 2006, P 3 AS C REFR AIR CO
[5]   The effects of design and operating factors on the frost growth and thermal performance of a flat plate fin-tube heat exchanger under the frosting condition [J].
Lee, KS ;
Kim, WS .
KSME INTERNATIONAL JOURNAL, 1999, 13 (12) :973-981
[6]  
LEE YH, 2006, P 2 INT C COOL HEAT
[7]  
Morimoto N., DEV PRACTICAL APPL H
[8]  
National Institute of Standards and Technology (NIST), THERM PROP FLUID SYS
[9]   Frost formation on fin-and-tube heat exchangers. Part I - Modeling of frost formation on fin-and-tube heat exchangers [J].
Seker, D ;
Karatas, H ;
Egrican, N .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04) :367-374
[10]   Frost formation on fin-and-tube heat exchangers. Part II - Experimental investigation of frost formation on fin-and-tube heat exchangers [J].
Seker, D ;
Karatas, H ;
Egrican, N .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04) :375-377