Pulmonary nodule registration: Rigid or nonrigid?

被引:12
|
作者
Gu, Suicheng [1 ]
Wilson, David [2 ]
Tan, Jun [1 ]
Pu, Jiantao [1 ,3 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Med, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15213 USA
基金
美国国家卫生研究院;
关键词
pulmonary nodule; rigid/nonrigid registration; Demons algorithm; follow-up study; DEFORMABLE REGISTRATION; LUNG REGISTRATION; SURFACES; CHEST;
D O I
10.1118/1.3602457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The primary aim of this study is to investigate the performance difference of rigid and nonrigid registration schemes in matching corresponding pulmonary nodules depicted on sequential chest computed tomography (CT) examinations. Methods: A gradient descent based rigid registration algorithm with scaling was developed and it handled the involved geometric transformations (i.e., translation, rescaling, shearing, and rotation) separately instead of optimizing them in a single pass. Given two lung CT examinations, the scaling and translation parameters were simply estimated from the lung volume dimensions (e.g., size and mass center), while the rotation parameters were optimized progressively using gradient descent. To investigate the performance difference of rigid and nonrigid schemes in pulmonary nodule registration, the well-known nonrigid Demons algorithm was implemented and tested along with the developed schemes against 60 diverse low-dose clinical lung CT examinations with average 2-yr follow-up scans. A verified cancer and its correspondence in the follow-up scan as well as their spatial locations (mass center) were identified in each examination. In addition to the computational efficiency, the accuracy of these registration procedures was assessed by computing the Euclidean distances between the corresponding nodules after the registration. To demonstrate the advantage of the developed algorithm, the authors also implemented a fast iterative closest point (ICP) based rigid algorithm and compared their performance. Results: Our experiments on the collected chest CT examinations showed that the nodule registration errors in 3D Euclidean distance for the developed rigid affine approach, the traditional ICP algorithm, and the refining nonrigid Demons algorithm were 9.6, 9.8, and 10.0 mm, respectively, and the corresponding computational costs in time were 5, 300, and 55 s, respectively. Conclusions: A rigid solution may be preferred in practice for the pulmonary nodule registration in longitudinal studies because of its relatively high efficiency and sufficient accuracy for the clinical need. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3602457]
引用
收藏
页码:4406 / 4414
页数:9
相关论文
共 50 条
  • [1] GGO Nodule Volume-Preserving Nonrigid Lung Registration Using GLCM Texture Analysis
    Park, Seongjin
    Kim, Bohyoung
    Lee, Jeongjin
    Goo, Jin Mo
    Shin, Yeong-Gil
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (10) : 2885 - 2894
  • [2] Image Registration Algorithm for Sequence Pathology Slices Of Pulmonary Nodule
    Liu, Qianqian
    Zhao, Gaofeng
    Deng, Jicai
    Xue, Qi
    Hou, Weiyan
    He, Yingzhe
    2019 8TH INTERNATIONAL SYMPOSIUM ON NEXT GENERATION ELECTRONICS (ISNE), 2019,
  • [3] Pulmonary nodule registration in serial CT scans using global rib matching and nodule template matching
    Jo, Hyun Hee
    Hong, Helen
    Goo, Jin Mo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 45 : 87 - 97
  • [4] A TOPOLOGICAL FEATURE CONSTRAINT FOR NONRIGID REGISTRATION
    Lin, Xiang-Bo
    Wang, Xin-Ning
    2014 IEEE CHINA SUMMIT & INTERNATIONAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING (CHINASIP), 2014, : 399 - 402
  • [5] Pulmonary nodule
    Feragalli, B
    Guido, F
    Larici, AR
    Storto, ML
    Bonomo, L
    RADIOLOGIA MEDICA, 2005, 110 (04): : 294 - 314
  • [6] Evaluation of nonrigid registration models for interfraction dose accumulation in radiotherapy
    Janssens, Guillaume
    de Xivry, Jonathan Orban
    Fekkes, Stein
    Dekker, Andre
    Macq, Benoit
    Lambin, Philippe
    van Elmpt, Wouter
    MEDICAL PHYSICS, 2009, 36 (09) : 4268 - 4276
  • [7] Regional information entropy Demons for infrared image nonrigid registration
    Lu Chaoliang
    Ma Lihua
    Yu Min
    Cui Shumin
    OPTIK, 2016, 127 (01): : 227 - 231
  • [8] Landmark detection in the chest and registration of lung surfaces with an application to nodule registration
    Betke, M
    Hong, H
    Thomas, D
    Prince, C
    Ko, JP
    MEDICAL IMAGE ANALYSIS, 2003, 7 (03) : 265 - 281
  • [9] A Solitary Pulmonary Nodule: Pulmonary Amyloidosis
    Standaert, Chloe
    Herpels, Vincent
    Seynaeve, Patrick
    JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2018, 102 (01)
  • [10] Nonrigid Registration of Ultrasound and MRI Using Contextual Conditioned Mutual Information
    Rivaz, Hassan
    Karimaghaloo, Zahra
    Fonov, Vladimir S.
    Collins, D. Louis
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (03) : 708 - 725