Zero-ischaemia robotic partial nephrectomy (RPN) for hilar tumours

被引:54
作者
Abreu, Andre L. C. [1 ]
Gill, Inderbir S. [1 ]
Desai, Mihir M. [1 ]
机构
[1] Univ So Calif, Keck Sch Med, Inst Urol, Ctr Adv Robot & Laparoscop Surg, Los Angeles, CA 90033 USA
关键词
robotic partial nephrectomy; hilar renal tumours; warm ischaemia time; vascular micro-dissection; zero-ischaemia; LAPAROSCOPIC PARTIAL NEPHRECTOMY; ASSISTED PARTIAL NEPHRECTOMY; CHRONIC KIDNEY-DISEASE; WARM ISCHEMIA; CARCINOMA;
D O I
10.1111/j.1464-410X.2011.10552.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Robotic partial nephrectomy (RPN) has emerged as an attractive minimally invasive nephron-sparing surgical option. However, on-going concerns about RPN include: (i) prolonged ischaemia time with potential implications on renal functional outcomes, and (ii) questions about the ability of RPN to address technically challenging hilar tumours. Herein, we detail the technique and present initial perioperative outcomes of our novel technique of zero-ischaemia RPN for complex hilar tumours. PATIENTS AND METHODS Since May 2010, >100 patients underwent minimally invasive zero-ischaemia PN. Of these, 21 had procedure done robotically. Of these, seven patients had hilar tumours. RPN was offered to all patients irrespective of tumour or reno-vascular anatomy, contralateral kidney characteristics or renal function. Data were prospectively collected and recorded in an Institutional Review Board-approved database. We detail our zero-ischaemia RPN technique and present early perioperative outcomes. RESULTS Zero-ischaemia RPN was successful in all cases without any hilar clamping. The median (range) tumour size was 4.1 (2.6-6.4) cm and the median RENAL score was 10 (8-10). The warm ischaemia time was zero in all cases. The median (range) operative time was 222 (150-330) min, estimated blood loss was 150 (100-500) mL, and the percentage kidney spared was 75 (50-90)%. The median hospital stay was 4 (3-6) days. There were no intraoperative complications; two patients had postoperative complications (Clavien grade I and II). No patient had a postoperative haemorrhage, urological/renal complication or lost a kidney. All tumour specimens had negative surgical margins on pathology. The median absolute decrease in serum creatinine and estimated glomerular filtration rate at discharge was 0 (0.2-0.7) mg/dL (P = 0.4) and 5 (-16 to 29) mL/min per 1.73 m(2) (P = 0.8), respectively. CONCLUSION Zero-ischaemia RPN for hilar tumours is safe and feasible and to our knowledge the first report in the literature. Elimination of warm ischaemia may optimally preserve renal function. Prospective randomized studies are needed to confirm any renal functional advantages of clamp-free RPN. Global renal ischaemia appears to be unnecessary during RPN for hilar tumours.
引用
收藏
页码:948 / 954
页数:7
相关论文
共 29 条
  • [1] Robot-Assisted Partial Nephrectomy: An International Experience
    Benway, Brian M.
    Bhayani, Sam B.
    Rogers, Craig G.
    Porter, James R.
    Buffi, Nicolo M.
    Figenshau, Robert S.
    Mottrie, Alexandre
    [J]. EUROPEAN UROLOGY, 2010, 57 (05) : 815 - 820
  • [2] Selective Versus Nonselective Arterial Clamping During Laparoscopic Partial Nephrectomy: Impact upon Renal Function in the Setting of a Solitary Kidney in a Porcine Model
    Benway, Brian M.
    Baca, Geneva
    Bhayani, Sam B.
    Das, Nitin A.
    Katz, Matthew D.
    Diaz, Dilmer L.
    Maxwell, Keegan L.
    Badwan, Khalid H.
    Talcott, Michael R.
    Liapis, Helen
    Cabello, Jose M.
    Venkatesh, Ramakrishna
    Figenshau, Robert S.
    [J]. JOURNAL OF ENDOUROLOGY, 2009, 23 (07) : 1127 - 1133
  • [3] Renal Damage Caused by Warm Ischaemia During Laparoscopic and Robot-Assisted Partial Nephrectomy: An Assessment Using Tc 99m-DTPA Glomerular Filtration Rate
    Choi, Jae Duck
    Park, Jong Wook
    Choi, Joon Young
    Kim, Hong Seok
    Jeong, Byong Chang
    Jeon, Seong Soo
    Lee, Hyun Moo
    Choi, Han Yong
    Seo, Seong Il
    [J]. EUROPEAN UROLOGY, 2010, 58 (06) : 900 - 905
  • [4] Classification of surgical complications - A new proposal with evaluation in a cohort of 6336 patients and results of a survey
    Dindo, D
    Demartines, N
    Clavien, PA
    [J]. ANNALS OF SURGERY, 2004, 240 (02) : 205 - 213
  • [5] Multi-Institutional Analysis of Robotic Partial Nephrectomy for Hilar Versus Nonhilar Lesions in 446 Consecutive Cases
    Dulabon, Lori M.
    Kaouk, Jihad H.
    Haber, Georges-Pascal
    Berkman, Douglas S.
    Rogers, Craig G.
    Petros, Firas
    Bhayani, Sam B.
    Stifelman, Michael D.
    [J]. EUROPEAN UROLOGY, 2011, 59 (03) : 325 - 330
  • [6] Innovations in laparoscopic and robotic partial nephrectomy: a novel 'zero ischemia' technique
    Eisenberg, Manuel S.
    Patil, Mukul B.
    Thangathurai, Duraiyah
    Gill, Inderbir S.
    [J]. CURRENT OPINION IN UROLOGY, 2011, 21 (02) : 93 - 98
  • [7] Comparison of 1,800 laparoscopic and open partial nephrectomies for single renal tumors
    Gill, Inderbir S.
    Kavoussi, Louis R.
    Lane, Brian R.
    Blute, Michael L.
    Babineau, Denise
    Colombo, J. Roberto, Jr.
    Frank, Igor
    Permpongkosol, Sompol
    Weight, Christopher J.
    Kaouk, Jihad H.
    Kattan, Michael W.
    Novick, Andrew C.
    [J]. JOURNAL OF UROLOGY, 2007, 178 (01) : 41 - 46
  • [8] "Zero Ischemia" Partial Nephrectomy: Novel Laparoscopic and Robotic Technique
    Gill, Inderbir S.
    Eisenberg, Manuel S.
    Aron, Monish
    Berger, Andre
    Ukimura, Osamu
    Patil, Mukul B.
    Campese, Vito
    Thangathurai, Duraiyah
    Desai, Mihir M.
    [J]. EUROPEAN UROLOGY, 2011, 59 (01) : 128 - 134
  • [9] Small Renal Mass
    Gill, Inderbir S.
    Aron, Monish
    Gervais, Debra A.
    Jewett, Michael A. S.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (07) : 624 - 634
  • [10] 800 Laparoscopic Partial Nephrectomies: A Single Surgeon Series
    Gill, Inderbir S.
    Kamoi, Kazumi
    Aron, Monish
    Desai, Mihir M.
    [J]. JOURNAL OF UROLOGY, 2010, 183 (01) : 34 - 41