Macroporous silicon based capacitive affinity sensor-fabrication and electrochemical studies

被引:49
作者
Betty, CA [1 ]
Lal, R
Sharma, DK
Yakhmi, JV
Mittal, JP
机构
[1] Bhabha Atom Res Ctr, Mod Labs, NM & SCD, Bombay 400085, Maharashtra, India
[2] Indian Inst Technol, Bombay 400076, Maharashtra, India
关键词
macroporous silicon; capacitance; impedance spectroscopy; affinity; sensor;
D O I
10.1016/j.snb.2003.09.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the fabrication and characterization of capacitive immunosensors based on electrolyte-insulator-porous silicon (EIS) structures. The sensor structure, gold\silicon\porous silicon\SiO2\aminosilane\glutaraldehyde\antibody\phosphate-buffered-saline (PBS)\platinum, is fabricated with a low thermal budget process and is found to be five times more sensitive than an immunosensor on polished silicon with identical die area. Macroporous silicon was prepared by electrochemical etching of polished (100) oriented p-type silicon wafers and characterized using SEM, optical microscopy, cyclic voltammetry and impedance spectroscopy. Columnar macroporous structures of different column densities and column sizes were used as the sensor substrates. The capacitive immunosensors were fabricated by anodic oxidation of these porous silicon substrates to form oxide followed by covalent immobilization of antibody (mouse IgG). Antibody-analyte (goat anti-mouse IgG) interactions were monitored via fluorescence microscopy and by change in the measured capacitance. Sensor response was dependent on both the porous silicon column structure and oxide quality. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:334 / 343
页数:10
相关论文
共 11 条
  • [1] DIRECT DETECTION OF IMMUNOSPECIES BY CAPACITANCE MEASUREMENTS
    BATAILLARD, P
    GARDIES, F
    JAFFREZICRENAULT, N
    MARTELET, C
    COLIN, B
    MANDRAND, B
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (21) : 2374 - 2379
  • [2] Bhagwati P, 1999, THESIS IIT BOMBAY
  • [3] INFLUENCE OF WETTABILITY ON ANODIC BIAS INDUCED ELECTROLUMINESCENCE IN POROUS SILICON
    HALIMAOUI, A
    [J]. APPLIED PHYSICS LETTERS, 1993, 63 (09) : 1264 - 1266
  • [4] A porous silicon-based optical interferometric biosensor
    Lin, VSY
    Motesharei, K
    Dancil, KPS
    Sailor, MJ
    Ghadiri, MR
    [J]. SCIENCE, 1997, 278 (5339) : 840 - 843
  • [5] INVESTIGATION OF DIFFERENT OXIDATION PROCESSES FOR POROUS SI BY XPS
    MUNDER, H
    BERGER, MG
    FROHNHOFF, S
    THONISSEN, M
    LUTH, H
    JESKE, M
    SCHULTZE, JW
    [J]. JOURNAL OF LUMINESCENCE, 1993, 57 (1-6) : 223 - 226
  • [6] The room temperature oxidation of porous silicon
    Salonen, J
    Lehto, VP
    Laine, E
    [J]. APPLIED SURFACE SCIENCE, 1997, 120 (3-4) : 191 - 198
  • [7] Miniaturization of potentiometric sensors using porous silicon microtechnology
    Schoning, MJ
    Ronkel, F
    Crott, M
    Thust, M
    Schultze, JW
    Kordos, P
    Luth, H
    [J]. ELECTROCHIMICA ACTA, 1997, 42 (20-22) : 3185 - 3193
  • [8] Analysis of the polymer-antibody-antigen interaction in a capacitive immunosensor by FTIR difference spectroscopy
    Sibai, A
    Elamri, K
    Barbier, D
    JaffrezicRenault, N
    Souteyrand, E
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1996, 31 (1-2) : 125 - 130
  • [9] DIRECT-DETECTION OF BIOMOLECULES BY ELECTROCHEMICAL IMPEDANCE MEASUREMENTS
    SOUTEYRAND, E
    MARTIN, JR
    MARTELET, C
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1994, 20 (01) : 63 - 69
  • [10] Starodub N. G., 1996, SENSOR ACTUAT B-CHEM, V44, P35