An inverse geometry CT system with stationary source arrays

被引:3
|
作者
Hsieh, Scott S. [1 ,2 ]
Heanue, Joseph A. [3 ]
Funk, Tobias [3 ]
Hinshaw, Waldo S. [2 ,3 ]
Pelc, Norbert J. [1 ,2 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Triple Ring Technol Inc, Newark, NY 94560 USA
来源
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING | 2011年 / 7961卷
关键词
computed tomography (CT); inverse-geometry; IGCT; stationary source;
D O I
10.1117/12.878801
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional CT systems face a tradeoff between temporal resolution, volumetric coverage and cone beam artifacts and also have limited ability to customize the distribution of incident x-rays to the imaging task. Inverse geometry CT (IGCT) can overcome some of these limitations by placing a small detector opposite a large, rotating scanned source array. It is difficult to quickly rotate this source array to achieve rapid imaging, so we propose using stationary source arrays instead and investigate the feasibility of such a system. We anticipate that distinct source arrays will need to be physically separated, creating gaps in the sinogram. Symmetry can be used to fill the missing rays except those connecting gaps. With three source arrays, a large triangular field of view emerges. As the small detector orbits the patient, each source spot must be energized at multiple specifically designed times to ensure adequate sampling. A timing scheme is proposed that avoids timing clashes, efficiently uses the detector, and allows for simple collimation. The two-dimensional MTF, noise characteristics, and artifact levels are all found to be comparable to parallel-beam systems. A complete, 100 millisecond volumetric scan may be feasible.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Optimizing parameters of an open-source airway segmentation algorithm using different CT images
    Pietro Nardelli
    Kashif A Khan
    Alberto Corvò
    Niamh Moore
    Mary J Murphy
    Maria Twomey
    Owen J O’Connor
    Marcus P Kennedy
    Raúl San José Estépar
    Michael M Maher
    Pádraig Cantillon-Murphy
    BioMedical Engineering OnLine, 14
  • [42] Dual-helical CT for detecting aortic atheromas as a source of stroke: Comparison with transesophageal echocardiography
    Tenenbaum, A
    Garniek, A
    Shemesh, J
    Fisman, EZ
    Stroh, CI
    Itzchak, Y
    Vered, Z
    Motro, M
    RADIOLOGY, 1998, 208 (01) : 153 - 158
  • [43] Projection-Wise Filter Optimization for Limited-Angle Cone-Beam CT Using the Approximate Inverse
    Muders, Jens
    Hesser, Juergen
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 148 - 163
  • [44] Calibration-Free Coronary Artery Measurements for Interventional Device Sizing using Inverse Geometry X-ray Fluoroscopy: In Vivo Validation
    Tomkowiak, Michael T.
    Raval, Amish N.
    Van Lysel, Michael S.
    Funk, Tobias
    Speidel, Michael A.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [45] Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation
    Tomkowiak, Michael T.
    Raval, Amish N.
    Van Lysel, Michael S.
    Funk, Tobias
    Speidel, Michael A.
    JOURNAL OF MEDICAL IMAGING, 2014, 1 (03)
  • [46] Design and Development of a Mobile Robotic CT System for Intraoperative Use
    Kim, Michael D.
    Lee, Kwang-Hee
    Lee, Sang-Moo
    Koo, Ja Choon
    Ji, Sang-Hoon
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2019, 24 (01) : 395 - 405
  • [47] Image fusion of CT and MRI for the visualization of the auditory and vestibular system
    Seemann, MD
    Beltle, J
    Heuschmid, M
    Löwenheim, H
    Graf, H
    Claussen, CD
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2005, 10 (02) : 47 - 55
  • [48] A Novel Static CT System: The Design of Triple Planes CT and Its Multi-Energy Simulation Results
    Yao, Yidi
    Li, Liang
    Chen, Zhiqiang
    FRONTIERS IN PHYSICS, 2021, 9
  • [49] A novel approach to CAD system for the detection of lung nodules in CT images
    Javaid, Muzzamil
    Javid, Moazzam
    Rehman, Muhammad Zia Ur
    Shah, Syed Irtiza Ali
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2016, 135 : 125 - 139
  • [50] Performance improvements of virtual monoenergetic images in photon-counting detector CT compared with dual source dual-energy CT: Fourier-based assessment
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Yoshida, Ryoichi
    Katayama, Takuto
    Arimoto, Makoto
    Kataoka, Jun
    Nagata, Hiroji
    Kobayashi, Satoshi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, : 143 - 153