An inverse geometry CT system with stationary source arrays

被引:3
|
作者
Hsieh, Scott S. [1 ,2 ]
Heanue, Joseph A. [3 ]
Funk, Tobias [3 ]
Hinshaw, Waldo S. [2 ,3 ]
Pelc, Norbert J. [1 ,2 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Triple Ring Technol Inc, Newark, NY 94560 USA
来源
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING | 2011年 / 7961卷
关键词
computed tomography (CT); inverse-geometry; IGCT; stationary source;
D O I
10.1117/12.878801
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional CT systems face a tradeoff between temporal resolution, volumetric coverage and cone beam artifacts and also have limited ability to customize the distribution of incident x-rays to the imaging task. Inverse geometry CT (IGCT) can overcome some of these limitations by placing a small detector opposite a large, rotating scanned source array. It is difficult to quickly rotate this source array to achieve rapid imaging, so we propose using stationary source arrays instead and investigate the feasibility of such a system. We anticipate that distinct source arrays will need to be physically separated, creating gaps in the sinogram. Symmetry can be used to fill the missing rays except those connecting gaps. With three source arrays, a large triangular field of view emerges. As the small detector orbits the patient, each source spot must be energized at multiple specifically designed times to ensure adequate sampling. A timing scheme is proposed that avoids timing clashes, efficiently uses the detector, and allows for simple collimation. The two-dimensional MTF, noise characteristics, and artifact levels are all found to be comparable to parallel-beam systems. A complete, 100 millisecond volumetric scan may be feasible.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A volumetric reconstruction algorithm for stationary source inverse-geometry CT
    Hsieh, Scott S.
    Pelc, Norbert J.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [2] Geometry analysis of an inverse-geometry volumetric CT system with multiple detector arrays
    Mazin, S
    Schmidt, TG
    Solomon, E
    Fahrig, R
    Pelc, N
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 320 - 329
  • [3] 2D simulations of an inverse-geometry volumetric CT system with multiple detector arrays
    Mazin, S
    Star-Lack, J
    Schmidt, TG
    Pelc, N
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 889 - 897
  • [4] Noise simulations for an inverse-geometry volumetric CT system
    Schmidt, TG
    Fahrig, R
    Pelc, NJ
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 420 - 427
  • [5] A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array
    Baek, Jongduk
    De Man, Bruno
    Uribe, Jorge
    Longtin, Randy
    Harrison, Daniel
    Reynolds, Joseph
    Neculaes, Bogdan
    Frutschy, Kristopher
    Inzinna, Louis
    Caiafa, Antonio
    Senzig, Robert
    Pelc, Norbert J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05): : 1189 - 1202
  • [6] MTF analysis of a prototype table-top inverse-geometry volumetric CT system
    Schmidt, TG
    Bennett, NR
    Mazin, SR
    Star-Lack, J
    Solomon, EG
    Pelc, NJ
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 171 - 178
  • [7] A new reconstruction method to improve SNR for an inverse geometry CT system
    Baek, Jongduk
    Pelc, Norbert J.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [8] What is inverse-geometry CT?
    Schmidt, Taly Gilat
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (03) : 145 - 148
  • [9] Two-dimensional reconstruction algorithm of an inverse-geometry volumetric CT system
    Baek, Jongduk
    Pelc, Norbert J.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [10] A SEMI-STATIONARY CT SYSTEM
    Chen, Yi
    Xi, Yan
    Zhao, Jun
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 1099 - 1102