An inverse geometry CT system with stationary source arrays

被引:3
|
作者
Hsieh, Scott S. [1 ,2 ]
Heanue, Joseph A. [3 ]
Funk, Tobias [3 ]
Hinshaw, Waldo S. [2 ,3 ]
Pelc, Norbert J. [1 ,2 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Triple Ring Technol Inc, Newark, NY 94560 USA
来源
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING | 2011年 / 7961卷
关键词
computed tomography (CT); inverse-geometry; IGCT; stationary source;
D O I
10.1117/12.878801
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional CT systems face a tradeoff between temporal resolution, volumetric coverage and cone beam artifacts and also have limited ability to customize the distribution of incident x-rays to the imaging task. Inverse geometry CT (IGCT) can overcome some of these limitations by placing a small detector opposite a large, rotating scanned source array. It is difficult to quickly rotate this source array to achieve rapid imaging, so we propose using stationary source arrays instead and investigate the feasibility of such a system. We anticipate that distinct source arrays will need to be physically separated, creating gaps in the sinogram. Symmetry can be used to fill the missing rays except those connecting gaps. With three source arrays, a large triangular field of view emerges. As the small detector orbits the patient, each source spot must be energized at multiple specifically designed times to ensure adequate sampling. A timing scheme is proposed that avoids timing clashes, efficiently uses the detector, and allows for simple collimation. The two-dimensional MTF, noise characteristics, and artifact levels are all found to be comparable to parallel-beam systems. A complete, 100 millisecond volumetric scan may be feasible.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The feasibility of an inverse geometry CT system with stationary source arrays
    Hsieh, Scott S.
    Heanue, Joseph A.
    Funk, Tobias
    Hinshaw, Waldo S.
    Wilfley, Brian P.
    Solomon, Edward G.
    Pelc, Norbert J.
    MEDICAL PHYSICS, 2013, 40 (03)
  • [2] A volumetric reconstruction algorithm for stationary source inverse-geometry CT
    Hsieh, Scott S.
    Pelc, Norbert J.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [3] Geometry analysis of an inverse-geometry volumetric CT system with multiple detector arrays
    Mazin, S
    Schmidt, TG
    Solomon, E
    Fahrig, R
    Pelc, N
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 320 - 329
  • [4] Raw data normalization for a multi source inverse geometry CT system
    Baek, Jongduk
    De Man, Bruno
    Harrison, Daniel
    Pelc, Norbert J.
    OPTICS EXPRESS, 2015, 23 (06): : 7514 - 7526
  • [5] Data normalization method for a multi-source inverse geometry CT system
    Baek, Jongduk
    Pelc, Norbert J.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [6] Initial results with a multi-source inverse-geometry CT system
    Baek, Jongduk
    Pelc, Norbert J.
    Deman, Bruno
    Uribe, Jorge
    Harrison, Daniel
    Reynolds, Joseph
    Neculaes, Bogdan
    Inzinna, Louis
    Caiafa, Antonio
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [7] Inverse-Geometry CT with Linearly Distributed Source and Detector: Stationary Configuration and Direct Filtered-Backprojection Reconstruction
    Zhang, Tao
    Xing, Yuxiang
    Gao, Hewei
    Chen, Zhiqiang
    Zhang, Li
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [8] 2D simulations of an inverse-geometry volumetric CT system with multiple detector arrays
    Mazin, S
    Star-Lack, J
    Schmidt, TG
    Pelc, N
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 889 - 897
  • [9] Multi-source inverse-geometry CT: from system concept to research prototype
    De Man, Bruno
    Caiafa, Antonio
    Cao, Yang
    Frutschy, Kristopher
    Harrison, Daniel
    Inzinna, Lou
    Longtin, Randy
    Neculaes, Bogdan
    Reynolds, Joseph
    Roy, Jaydeep
    Short, Jonathan
    Uribe, Jorge
    Waters, William
    Yin, Zhye
    Zhang, Xi
    Zou, Yun
    Senzig, Bob
    Baek, Jongduk
    Pelc, Norbert
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3531 - +
  • [10] Inverse Geometry CT
    Pelc, N.
    MEDICAL PHYSICS, 2011, 38 (06) : 3773 - +