Enhancement of capnogram waveform in the presence of chest compression artefact during cardiopulmonary resuscitation

被引:9
|
作者
Ruiz de Gauna, Sofia [1 ]
Leturiondo, Mikel [1 ]
Gutierrez, J. Julio [1 ]
Ruiz, Jesus M. [1 ]
Gonzalez-Otero, Digna M. [1 ]
Russell, James K. [2 ]
Daya, Mohamud [2 ]
机构
[1] Univ Basque Country, UPV EHU, Dept Commun Engn, Bilbao 48013, Spain
[2] Oregon Hlth & Sci Univ, Dept Emergency Med, Portland, OR 97239 USA
关键词
Cardiopulmonary resuscitation; Advanced life support; Waveform capnography; Ventilation; Chest compressions; Chest compression artefact; VENTILATION DETECTION; MONITOR VENTILATION; CARBON-DIOXIDE; FEASIBILITY; GUIDELINES; ALGORITHMS; REMOVAL; CPR;
D O I
10.1016/j.resuscitation.2018.09.024
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Current resuscitation guidelines emphasize the use of waveform capnography to help guide rescuers during cardiopulmonary resuscitation (CPR). However, chest compressions often cause oscillations in the capnogram, impeding its reliable interpretation, either visual or automated. The aim of the study was to design an algorithm to enhance waveform capnography by suppressing the chest compression artefact. Methods: Monitor-defibrillator recordings from 202 patients in out-of-hospital cardiac arrest were analysed. Capnograms were classified according to the morphology of the artefact. Ventilations were annotated using the transthoracic impedance signal acquired through defibrillation pads. The suppression algorithm is designed to operate in real-time, locating distorted intervals and restoring the envelope of the capnogram. We evaluated the improvement in automated ventilation detection, estimation of ventilation rate, and detection of excessive ventilation rates (over-ventilation) using the capnograms before and after artefact suppression. Results: A total of 44 267 ventilations were annotated. After artefact suppression, sensitivity (Se) and positive predictive value (PPV) of the ventilation detector increased from 91.9/89.5% to 98.0/97.3% in the distorted episodes (83/202). Improvement was most noticeable for high-amplitude artefact, for which Se/PPV raised from 77.6/73.5% to 97.1/96.1%. Estimation of ventilation rate and detection of over-ventilation also upgraded. The suppression algorithm had minimal impact in non-distorted data. Conclusion: Ventilation detection based on waveform capnography improved after chest compression artefact suppression. Moreover, the algorithm enhances the capnogram tracing, potentially improving its clinical interpretation during CPR. Prospective research in clinical settings is needed to understand the feasibility and utility of the method.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [31] Comparison of two infant chest compression techniques during simulated newborn cardiopulmonary resuscitation performed by a single rescuer: A randomized, crossover multicenter trial
    Smereka, Jacek
    Madziala, Marcin
    Szarpak, Lukasz
    CARDIOLOGY JOURNAL, 2019, 26 (06) : 761 - 768
  • [32] Optimal Chest Compression Position for Patients With a Single Ventricle During Cardiopulmonary Resuscitation*
    Park, Jung-Bin
    Song, In-Kyung
    Lee, Ji-Hyun
    Kim, Eun-Hee
    Kim, Hee-Soo
    Kim, Jin-Tae
    PEDIATRIC CRITICAL CARE MEDICINE, 2016, 17 (04) : 303 - 306
  • [33] Chest Compression Induced Ventricular Activation, a Novel Phenomenon, During Cardiopulmonary Resuscitation
    Hoogkamp, Nienke
    Pijls, Ruud W. M.
    Gorgels, Anton P. M.
    CIRCULATION, 2014, 130
  • [34] Rate at 120/min provides qualified chest compression during cardiopulmonary resuscitation
    Zou, Yaru
    Shi, Wen
    Zhu, Ying
    Tao, Ranjun
    Jiang, Ying
    Li, Shanfeng
    Ye, Jing
    Lu, Yiming
    Jiang, Jie
    Tong, Jianjing
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (04) : 535 - 538
  • [35] Active chest compression-decompression for cardiopulmonary resuscitation
    Lafuente-Lafuente, Carmelo
    Melero-Bascones, Maria
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (09):
  • [37] Cardiopulmonary Resuscitation by Chest Compression Alone: A Reality Check
    Papadima, Artemisia
    Pappas, Apostolos B.
    Lagoudianakis, Emmanuel E.
    Kotzadimitriou, Aikaterini
    Markogiannakis, Haridimos
    Filis, Konstantinos
    Vavouranakis, Emmanuel
    Manouras, Andreas
    Xanthos, Theodoros
    Papadimitriou, Lila
    HELLENIC JOURNAL OF CARDIOLOGY, 2010, 51 (01) : 55 - 61
  • [38] Chest compression release and recoil dynamics in prolonged manual cardiopulmonary resuscitation
    Russell, James Knox
    Leturiondo, Mikel
    Gonzalez-Otero, Digna M.
    Gutierrez, Jose Julio
    Daya, Mohamud Ramzan
    de Gauna, Sofia Ruiz
    RESUSCITATION, 2021, 167 : 180 - 187
  • [39] Chest compressions during ventilation in out-of-hospital cardiopulmonary resuscitation cause fragmentation of the airflow
    Van Den Daele, Cel
    Vanwulpen, Maxim
    Hachimi-Idrissi, Said
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 50 : 455 - 458
  • [40] A new physiological model for studying the effect of chest compression and ventilation during cardiopulmonary resuscitation: The Thiel cadaver
    Charbonney, Emmanuel
    Delisle, Stephane
    Savary, Dominique
    Bronchti, Gilles
    Rigollot, Marceau
    Drouet, Adrien
    Badat, Bilal
    Ouellet, Paul
    Gosselin, Patrice
    Mercat, Alain
    Brochard, Laurent
    Richard, Jean-Christophe M.
    RESUSCITATION, 2018, 125 : 135 - 142