Imaging sequence for joint myocardial T1 mapping and fat/water separation

被引:16
作者
Nezafat, Maryam [1 ,2 ,3 ]
Nakamori, Shiro [2 ,3 ]
Basha, Tamer A. [4 ]
Fahmy, Ahmed S. [2 ,3 ]
Hauser, Thomas [2 ,3 ]
Botnar, Rene M. [1 ,5 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
[2] Beth Israel Deaconess Med Ctr, Dept Med, Boston, MA 02215 USA
[3] Harvard Med Sch, Boston, MA USA
[4] Cairo Univ, Dept Biomed Engn, Giza, Egypt
[5] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
美国国家卫生研究院; 英国惠康基金; 英国工程与自然科学研究理事会;
关键词
cardiac magnetic resonance imaging; Dixon; myocardial tissue characterization; T-1; mapping; EPICARDIAL ADIPOSE-TISSUE; INVERSION-RECOVERY MOLLI; LOOK-LOCKER; MAGNETIC-RESONANCE; FAT; FIBROSIS; HEART; CARDIOMYOPATHY; INFILTRATION; VALIDATION;
D O I
10.1002/mrm.27390
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and evaluate an imaging sequence to simultaneously quantify the epicardial fat volume and myocardial T-1 relaxation time. Methods: We introduced a novel simultaneous myocardial T-1 mapping and fat/water separation sequence (joint T-1-fat/water separation). Dixon reconstruction is performed on a dual-echo data set to generate water/fat images. T-1 maps are computed using the water images, whereas the epicardial fat volume is calculated from the fat images. A phantom experiment using vials with different T-1/T-2 values and a bottle of oil was performed. Additional phantom experiment using vials of mixed fat/water was performed to show the potential of this sequence to mitigate the effect of intravoxel fat on estimated T-1 maps. In vivo evaluation was performed in 17 subjects. Epicardial fat volume, native myocardial T-1 measurements and precision were compared among slice-interleaved T-1 mapping, Dixon, and the proposed sequence. Results: In the first phantom, the proposed sequence separated oil from water vials and there were no differences in T-1 of the fat-free vials (P=.1). In the second phantom, the T-1 error decreased from 22%, 36%, 57%, and 73% to 8%, 9%, 16%, and 26%, respectively. In vivo there was no difference between myocardial T-1 values (1067 +/- 17 ms versus 1077 +/- 24 ms, P=.6). The epicardial fat volume was similar for both sequences (54.3 +/- 33 cm(3) versus 52.4 +/- 32 cm(3), P=.8). Conclusion: The proposed sequence provides simultaneous quantification of native myocardial T1 and epicardial fat volume. This will eliminate the need for an additional sequence in the cardiac imaging protocol if both measurements are clinically indicated.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
[41]   3D myocardial T1 mapping using saturation recovery [J].
Nordio, Giovanna ;
Henningsson, Markus ;
Chiribiri, Amedeo ;
Villa, Adriana D. M. ;
Schneider, Torben ;
Botnar, Rene M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (01) :218-227
[42]   Modified cine inversion recovery pulse sequence for the quantification of myocardial T1 and gadolinium partition coefficient [J].
Milanesi, Matteo ;
Barison, Andrea ;
Positano, Vincenzo ;
Masci, Pier Giorgio ;
De Marchi, Daniele ;
Marinelli, Luca ;
Hardy, Christopher J. ;
Foo, Thomas K. ;
Landini, Luigi ;
Lombardi, Massimo .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (01) :109-118
[43]   Myocardial Late Gadolinium Enhancement: Accuracy of T1 Mapping-based Synthetic Inversion-Recovery Imaging [J].
Varga-Szemes, Akos ;
van der Geest, Rob J. ;
Spottiswoode, Bruce S. ;
Suranyi, Pal ;
Ruzsics, Balazs ;
De Cecco, Carlo N. ;
Muscogiuri, Giuseppe ;
Cannao, Paola M. ;
Fox, Mary A. ;
Wichmann, Julian L. ;
Vliegenthart, Rozemarijn ;
Schoepf, U. Joseph .
RADIOLOGY, 2016, 278 (02) :374-382
[44]   Myocardial Fat Deposition after Left Ventricular Myocardial Infarction: Assessment by Using MR Water-Fat Separation Imaging [J].
Goldfarb, James W. ;
Roth, Marguerite ;
Han, Jing .
RADIOLOGY, 2009, 253 (01) :65-73
[45]   Can native T1 mapping sequence be used as a non-invasive alternative imaging tool to LGE sequence for evaluating DCM patients? [J].
Badr, Shimaa Elsayed ;
Gouhar, Ghada Kamal ;
Zidan, Elsayed Hamed ;
Shehata, Samar Mohamad ;
Roshdy, Hisham Samir ;
Abdelhay, Rabab Mohamed ;
Ebaid, Noha Yahia .
EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01)
[46]   Optimization and comparison of myocardial T1 techniques at 3T in patients with aortic stenosis [J].
Chin, Calvin W. L. ;
Semple, Scott ;
Malley, Tamir ;
White, Audrey C. ;
Mirsadraee, Saeed ;
Weale, Peter J. ;
Prasad, Sanjay ;
Newby, David E. ;
Dweck, Marc R. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (05) :556-565
[47]   Saturation pulse design for quantitative myocardial T1 mapping [J].
Chow, Kelvin ;
Kellman, Peter ;
Spottiswoode, Bruce S. ;
Nielles-Vallespin, Sonia ;
Arai, Andrew E. ;
Salerno, Michael ;
Thompson, Richard B. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[48]   T1 Mapping in Characterizing Myocardial Disease A Comprehensive Review [J].
Puntmann, Valentina O. ;
Peker, Elif ;
Chandrashekhar, Y. ;
Nagel, Eike .
CIRCULATION RESEARCH, 2016, 119 (02) :277-299
[49]   Prognostic Significance of Remote Myocardium Alterations Assessed by Quantitative Noncontrast T1 Mapping in ST-Segment Elevation Myocardial Infarction [J].
Reinstadler, Sebastian J. ;
Stiermaier, Thomas ;
Liebetrau, Johanna ;
Fuernau, Georg ;
Eitel, Charlotte ;
de Waha, Suzanne ;
Desch, Steffen ;
Reil, Jan-Christian ;
Poess, Janine ;
Metzler, Bernhard ;
Luecke, Christian ;
Gutberlet, Matthias ;
Schuler, Gerhard ;
Thiele, Holger ;
Eitel, Ingo .
JACC-CARDIOVASCULAR IMAGING, 2018, 11 (03) :411-419
[50]   Correction with blood T1 is essential when measuring post-contrast myocardial T1 value in patients with acute myocardial infarction [J].
Choi, Eui-Young ;
Hwang, Sung Ho ;
Yoon, Young Won ;
Park, Chul Hwan ;
Paek, Mun Young ;
Greiser, Andreas ;
Chung, Hyemoon ;
Yoon, Ji-Hyun ;
Kim, Jong-Youn ;
Min, Pil-Ki ;
Lee, Byoung Kwon ;
Hong, Bum-Kee ;
Rim, Se-Joong ;
Kwon, Hyuck Moon ;
Kim, Tae Hoon .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15