Automated Iterative MS/MS Acquisition: A Tool for Improving Efficiency of Protein Identification Using a LC-MALDI MS Workflow

被引:12
作者
Liu, Haichuan [1 ,2 ]
Yang, Lee [3 ]
Khainovski, Nikita
Dong, Ming [3 ]
Hall, Steven C. [1 ,2 ]
Fisher, Susan J. [1 ,2 ]
Biggin, Mark D. [3 ]
Jin, Jian [3 ]
Witkowska, H. Ewa [1 ,2 ]
机构
[1] Univ Calif San Francisco, UCSF Sandler Moore Mass Spectrometry Core Facil, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Obstet Gynecol & Reprod Sci, San Francisco, CA 94143 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
关键词
PRECURSOR ION SELECTION; MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; SHOTGUN PROTEOMICS; RETENTION TIMES; NEXT-GENERATION; PREDICTION; PEPTIDES; STRATEGY; QUANTITATION;
D O I
10.1021/ac200911v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed an information-dependent, iterative MS/MS acquisition (IMMA) tool for improving MS/MS efficiency, increasing proteome coverage, and shortening analysis time for high-throughput proteomics applications based on the LC-MALDI MS/MS platform. The underlying principle of IMMA is to limit MS/MS analyses to a subset of molecular ions that are likely to identify a maximum number of proteins. IMMA reduces redundancy of MS/MS analyses by excluding from the precursor ion peak lists proteotypic peptides derived from the already identified proteins and uses a retention time prediction algorithm to limit the degree of false exclusions. It also increases the utilization rate of MS/MS spectra by removing "low value" unidentifiable targets like nonpeptides and peptides carrying large loads of modifications, which are flagged by their "nonpeptide" excess-to-nominal mass ratios. For some samples, IMMA increases the number of identified proteins by similar to 20-40% when compared to the data dependent methods. IMMA terminates an MS/MS run at the operator defined point when "costs" (e.g, time of analysis) start to overrun "benefits" (e.g, number of identified proteins), without prior knowledge of sample contents and complexity. To facilitate analysis of closely related samples, IMMA's inclusion list functionality is currently under development.
引用
收藏
页码:6286 / 6293
页数:8
相关论文
共 50 条
  • [1] Optimal precursor ion selection for LC-MALDI MS/MS
    Zerck, Alexandra
    Nordhoff, Eckhard
    Lehrach, Hans
    Reinert, Knut
    BMC BIOINFORMATICS, 2013, 14
  • [2] Peptidome Analysis of Cerebrospinal Fluid by LC-MALDI MS
    Holtta, Mikko
    Zetterberg, Henrik
    Mirgorodskaya, Ekaterina
    Mattsson, Niklas
    Blennow, Kaj
    Gobom, Johan
    PLOS ONE, 2012, 7 (08):
  • [3] Automated Precursor Ion Exclusion During LC-MS/MS Data Acquisition for Optimal Ion Identification
    Zhang, Zhongqi
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (08) : 1400 - 1407
  • [4] Semi-Targeted Plasma Proteomics Discovery Workflow Utilizing Two-Stage Protein Depletion and Off-Line LC-MALDI MS/MS
    Juhasz, Peter
    Lynch, Moira
    Sethuraman, Mahadevan
    Campbell, Jennifer
    Hines, Wade
    Paniagua, Manuel
    Song, Leijun
    Kulkarni, Mahesh
    Adourian, Aram
    Guo, Yu
    Li, Xiaohong
    Martin, Stephen
    Gordon, Neal
    JOURNAL OF PROTEOME RESEARCH, 2011, 10 (01) : 34 - 45
  • [5] Improving Natural Products Identification through Targeted LC-MS/MS in an Untargeted Secondary Metabolomics Workflow
    Hoffmann, Thomas
    Krug, Daniel
    Huettel, Stephan
    Mueller, Rolf
    ANALYTICAL CHEMISTRY, 2014, 86 (21) : 10780 - 10788
  • [6] Detection and identification of a protein biomarker in antibiotic-resistant Escherichia coli using intact protein LC offline MALDI-MS and MS/MS
    Maus, A.
    Bisha, B.
    Fagerquist, C.
    Basile, F.
    JOURNAL OF APPLIED MICROBIOLOGY, 2020, 128 (03) : 697 - 709
  • [7] Protein identification using a nanoUHPLC-AP-MALDI MS/MS workflow with CID of multiply charged proteolytic peptides
    Ryumin, Pavel
    Brown, Jeffery
    Morris, Michael
    Cramer, Rainer
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 416 : 20 - 28
  • [8] Protein identification using 2D-LC-MS/MS
    Delahunty, C
    Yates, JR
    METHODS, 2005, 35 (03) : 248 - 255
  • [9] Automated SPR-LC-MS/MS system for protein interaction analysis
    Hayano, Toshiya
    Yamauchi, Yoshio
    Asano, Kazunobu
    Tsujimura, Teruko
    Hashimoto, Setsuko
    Isobe, Toshiaki
    Takahashi, Nobuhiro
    JOURNAL OF PROTEOME RESEARCH, 2008, 7 (09) : 4183 - 4190
  • [10] Automated saliva processing for LC-MS/MS: Improving laboratory efficiency in cortisol and cortisone testing
    Antonelli, Giorgia
    Padoan, Andrea
    Artusi, Carlo
    Marinova, Mariela
    Zaninotto, Martina
    Plebani, Mario
    CLINICAL BIOCHEMISTRY, 2016, 49 (06) : 518 - 520