Motion Artifact-Resilient Zone for Implantable Sensors

被引:7
|
作者
Jeong, Chanho [1 ,2 ]
Koirala, Gyan Raj [3 ]
Jung, Yei Hwan [4 ]
Ye, Yeong Sinn [3 ]
Hyun, Jeong Hun [3 ]
Kim, Tae Hee [5 ]
Park, Byeonghak [3 ]
Ok, Jehyung [3 ]
Jung, Youngmee [5 ,6 ]
Kim, Tae-il [3 ]
机构
[1] Sungkyunkwan Univ SKKU, Dept Biomed Engn, Suwon 16419, South Korea
[2] Carnegie Mellon Univ, Dept Mech Engn, Pittsburgh, PA 15213 USA
[3] Sungkyunkwan Univ SKKU, Sch Chem Engn, Suwon 16419, South Korea
[4] Hanyang Univ, Dept Elect Engn, Seoul 04763, South Korea
[5] Korea Inst Sci & Technol KIST, Biomed Res Inst, Ctr Biomat, Seoul 02792, South Korea
[6] Yonsei Univ, YU KIST Inst, Sch Elect & Elect Engn, Seoul 03722, South Korea
基金
新加坡国家研究基金会;
关键词
film sensors; implantable devices; motion artifacts; noise-free; tactile sensors; wearable sensors;
D O I
10.1002/adfm.202206461
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The miniaturization and flexibility of wearable and implantable devices allow humans to carry them directly on or in their bodies, thus enabling these devices to measure biometric signals in real-time anywhere. However, as they are embedded or implanted into an actively moving human interface, motion artifact noise inevitably occurs. Typically, devices are laminated or implanted on body surfaces, but the positions of such devices cannot be designed without any discussion of the noise. Thus, this paper investigates an approach that minimizes the noise to achieve negligible motion artifacts in implantable micro-devices that have a specific angle on the surface of the body, while maintaining the function of sensor. The device with a specific angle successfully detects the target signal, while motion artifacts-such as tension, compression, and bending-disturb the measurement. The pulse signal on a wrist is well measured while the hand is rotating, and artificial skin implanted on a rat can distinguish external pressure from the movement noise. A thermometer sensor that follows the same rule is further examined. Therefore, this approach is expected to be useful in numerous areas including human interface-based medical devices, virtual reality, and health aids to improve quality of life.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Rigid motion artifact reduction in CT using frequency domain analysis
    Zhang, Yuan
    Zhang, Liyi
    Sun, Yunshan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (05) : 721 - 736
  • [42] Two-Pronged Motion Artifact Reduction for Wearable Photoplethysmographic Biosensors
    Jiang, Yuan
    IEEE SENSORS LETTERS, 2018, 2 (04)
  • [43] Rigid Motion Artifact Reduction in CT Using the Phase Correlation Method
    Zhang, Yuan
    Zhang, Liyi
    Sun, Yunshan
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2020, 13 (08) : 1119 - 1128
  • [44] A Novel Method for Automatic Identification of Motion Artifact Beats in ECG Recordings
    Tu, Yuewen
    Fu, Xiuquan
    Li, Dingli
    Huang, Chao
    Tang, Yawei
    Ye, Shuming
    Chen, Hang
    ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (09) : 1917 - 1928
  • [45] Motion Artifact Compensation for Photoplethysmographic Signals by Help of Adaptive Noise Cancelation
    Volmer, Achim
    Orglmeister, Reinhold
    Feese, Sebastian
    AT-AUTOMATISIERUNGSTECHNIK, 2010, 58 (05) : 269 - 276
  • [46] New techniques for motion-artifact-free in vivo cardiac microscopy
    Vinegoni, Claudio
    Lee, Sungon
    Aguirre, Aaron D.
    Weissleder, Ralph
    FRONTIERS IN PHYSIOLOGY, 2015, 6
  • [47] Wireless Energy Delivery and Data Communication for Biomedical Sensors and Implantable devices
    Zhang, Fei
    Liu, Xiaoyu
    Hackworth, Steven A.
    Sclabassi, Robert J.
    Sun, Mingui
    2009 35TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2009, : 218 - +
  • [48] Recent Advances in Wearable Flexible Sensors and Implantable Biotags for Aquatic Animals
    Wang, Lu
    Gai, Yansong
    He, Qipei
    Kang, Jiajie
    Wang, Kaijie
    Jiang, Yonggang
    ADVANCED MATERIALS TECHNOLOGIES, 2024, 9 (12)
  • [49] PPG motion artifact handling using a self-mixing interferometric sensor
    Wijshoff, Ralph W. C. G. R.
    Veen, Jeroen
    van der Lee, Alexander M.
    Mulder, Lars
    Stijnen, Marco
    van Tuijl, Sjoerd
    Aarts, Ronald M.
    OPTICAL FIBERS, SENSORS, AND DEVICES FOR BIOMEDICAL DIAGNOSTICS AND TREATMENT XI, 2011, 7894
  • [50] Spectral Characteristics of Motion Artifacts in Wireless ECG and their Correlation with Reference Motion Sensors
    Lilienthal, Jannis
    Dargie, Waltenegus
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 517 - 521