Positron emission tomography/magnetic resonance imaging: The next generation of multimodality imaging?

被引:159
作者
Pichler, Bernd J. [1 ]
Wehrl, Hans F. [1 ]
Kolb, Armin [1 ]
Judenhofer, Martin S. [1 ]
机构
[1] Univ Tubingen, Werner Siemens Fdn, Dept Radiol, Lab Preclin Imaging & Imaging Technol, D-72076 Tubingen, Germany
关键词
D O I
10.1053/j.semnuclmed.2008.02.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multimodal imaging is now well-established in routine clinical practice. Especially in the field of nuclear medicine, new positron emission tomography (PET) installations comprise almost exclusively combined PET/computed tomography (CT) scanners rather than PET-only systems. However, PET/CT has certain notable shortcomings, including the inability to perform simultaneous data acquisition and the significant radiation dose to the patient contributed by CT. Magnetic resonance imaging (MRI) offers, compared with CT, better contrast among soft tissues as well as functional-imaging capabilities. Therefore, the combination of PET with MRI provides many advantages that go far beyond simply combining functional PET information with structural MRI information. Many technical challenges., including possible interference between these modalities, have to be solved when combining PET and MRI, and various approaches have been adapted to resolving these issues. Here, we present an overview of current working prototypes of combined PET/MRI scanners from different groups. In addition, besides PET/MRI images of mice, the first such images of a rat acquired with the first commercial clinical PET/MRI scanner, are presented. The combination of PET and MRI is a promising tool in preclinical research and will certainly progress to clinical application.
引用
收藏
页码:199 / 208
页数:10
相关论文
共 47 条
  • [1] Accuracy of whole-body dual-modality fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT) for tumor staging in solid tumors: Comparison with CT and PET
    Antoch, G
    Saoudi, N
    Kuehl, H
    Dahmen, G
    Mueller, SP
    Beyer, T
    Bockisch, A
    Debatin, JF
    Freudenberg, LS
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (21) : 4357 - 4368
  • [2] Bar-Shalom R, 2003, J NUCL MED, V44, P1200
  • [3] Barentsz JO, 1996, EUR RADIOL, V6, P129
  • [4] Beyer T, 2000, J NUCL MED, V41, P1369
  • [5] Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology
    Beyer, T
    Antoch, G
    Blodgett, T
    Freudenberg, LF
    Akhurst, T
    Mueller, S
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) : 588 - 596
  • [6] Brechtel K, 2006, J NUCL MED, V47, P470
  • [7] Brix G, 2005, J NUCL MED, V46, P608
  • [8] A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY
    CASEY, ME
    NUTT, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 460 - 463
  • [9] Catana C, 2006, J NUCL MED, V47, P1968
  • [10] Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging
    Cherry, SR
    Shao, YP
    Siegel, S
    Silverman, RW
    Mumcuoglu, E
    Meadors, K
    Phelps, ME
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1932 - 1937