Particulate matter in residential buildings in New Zealand: Part I. Variability of particle transport into unoccupied spaces with mechanical ventilation

被引:5
作者
Wallis, Shannon L. [1 ]
Hernandez, German [1 ]
Poyner, David [1 ]
Birchmore, Roger [2 ]
Berry, Terri-Ann [1 ]
机构
[1] Unitec Inst Technol, Engn Pathway, Auckland, New Zealand
[2] Unitec Inst Technol, Construct Pathway, Auckland, New Zealand
来源
ATMOSPHERIC ENVIRONMENT-X | 2019年 / 2卷
关键词
Particulate matter; Indoor air quality; Mechanical ventilation; Infiltration factor; I/O ratios; New Zealand; ULTRAFINE PARTICLES; OUTDOOR PARTICLES; AIR-POLLUTION; INDOOR; PM2.5; FINE; INHALATION; MORTALITY; QUALITY; NUMBER;
D O I
10.1016/j.aeaoa.2019.100024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Air pollution measured as particulate matter (PM) has been shown to be detrimental to human health and can lead to increased mortality rates. There are four main indoor sources of episodic PM emissions: smoking, cooking, cleaning and resuspension. This study has eliminated all human activity and provides data on the variability of the contribution from external sources via mechanical ventilation. The transportation of PM from an external to internal environment by mechanical ventilation is investigated in the same room in two, similar timber-framed houses, constructed identically apart from details affecting their airtightness. There was significant variation in the transportation of PM from an external to internal environment in two similar houses ([PM] Control > [PM] Test (rho = 0.001)) despite both houses operating the same mechanical ventilation system. Mean internal PM10 concentrations = 2.4 mu g m(-3) (Control) and 1.3 mu g m(-3) (Test) with corresponding mean external PM10 concentrations of 5.4 mu g m(-3) and 5.2 mu g m(-3) respectively. Particle removal efficiency between the two houses varied by approximately 20%. These findings indicate that there is considerable variation in filtration efficiencies even when the same mechanical ventilation system is in use in similar homes in the same location. The infiltration factor (F-inf) was calculated and demonstrated considerable variability both between houses (Control-Test PM10 0.40-0.23) and over time (Control PM10 0.40-0.18) which indicates that relationship between external and internal concentrations of PM is not linear and should therefore be used with caution. This questions simplifying F-inf into one factor as there are likely to be multiple contributing factors. For example, the effect of air flow on particle adsorption to internal surfaces, natural variations in filter efficiency and variations in particle loss. Over the duration of this study, PM concentrations decreased in both bedrooms by 52% (Control) and 37% (Test), which may be due to a number of factors including changes in internal environmental conditions, filter age and the cumulative effect of the use of mechanical ventilation over time reducing the transportation of PM into the houses.
引用
收藏
页数:9
相关论文
共 40 条
  • [1] Andersson J., 2011, REHVA J
  • [2] [Anonymous], 1998, 7726 ISO
  • [3] [Anonymous], 2010, J EPIDEMIOL COMMUNIT
  • [4] [Anonymous], WHO STEPS STROK MAN
  • [5] [Anonymous], 2013, 6212013 ASHRAE
  • [6] Auckland Council, 2015, HLTH AUCKL NAT ENV 2, P39
  • [7] Auckland Council, 2017, MAN AUCKL AIR QUAL
  • [8] Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin
    Azimi, Parham
    Zhao, Dan
    Stephens, Brent
    [J]. ATMOSPHERIC ENVIRONMENT, 2014, 98 : 337 - 346
  • [9] Impact of natural versus mechanical ventilation on simulated indoor air quality and energy consumption in offices in fourteen US cities
    Ben-David, Tom
    Waring, Michael S.
    [J]. BUILDING AND ENVIRONMENT, 2016, 104 : 320 - 336
  • [10] Buckett N., 2014, SR311 BRANZ