Highly sensitive colorimetric detection of glucose and uric acid in biological fluids using chitosan-modified paper microfluidic devices

被引:153
作者
Gabriel, Ellen F. M. [1 ]
Garcia, Paulo T. [1 ]
Cardoso, Thiago M. G. [1 ]
Lopes, Flavio M. [2 ]
Martins, Felipe T. [1 ]
Coltro, Wendell K. T. [1 ]
机构
[1] Univ Fed Goias, Inst Quim, BR-74690900 Goiania, Go, Brazil
[2] Univ Fed Goias, Fac Farm, BR-74605170 Goiania, Go, Brazil
关键词
ELECTROCHEMISTRY; NANOPARTICLES; SMARTPHONE; PLATFORMS; SURFACE;
D O I
10.1039/c6an00430j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the modification of microfluidic paper-based analytical devices (mu PADs) with chitosan to improve the analytical performance of colorimetric measurements associated with enzymatic bioassays. Chitosan is a natural biopolymer extensively used to modify biosensing surfaces due to its capability of providing a suitable microenvironment for the direct electron transfer between an enzyme and a reactive surface. This hypothesis was investigated using glucose and uric acid (UA) colorimetric assays as model systems. The best colorimetric sensitivity for glucose and UA was achieved using a chromogenic solution composed of 4-aminoantipyrine and sodium 3,5-dichloro-2-hydroxy-benzenesulfonate (4-AAP/DHBS), which provided a linear response for a concentration range between 0.1 and 1.0 mM. Glucose and UA were successfully determined in artificial serum samples with accuracies between 87 and 114%. The limits of detection (LODs) found for glucose and UA assays were 23 and 37 mu M, respectively. The enhanced analytical performance of chitosan-modified mu PADs allowed the colorimetric detection of glucose in tear samples from four nondiabetic patients. The achieved concentration levels ranged from 130 to 380 mu M. The modified mu PADs offered analytical reliability and accuracy as well as no statistical difference from the values achieved through a reference method. Based on the presented results, the proposed mu PAD can be a powerful alternative tool for non-invasive glucose analysis.
引用
收藏
页码:4749 / 4756
页数:8
相关论文
共 59 条
  • [21] Tear fluid content of electrochemically active components including water soluble antioxidants
    Gogia, R
    Richer, SP
    Rose, RC
    [J]. CURRENT EYE RESEARCH, 1998, 17 (03) : 257 - 263
  • [22] Direct Determination of Chitosan-Mucin Interactions Using a Single-Molecule Strategy: Comparison to Alginate-Mucin Interactions
    Haugstad, Kristin E.
    Hati, Armend G.
    Nordgard, Catherine T.
    Adl, Patricia S.
    Maurstad, Gjertrud
    Sletmoen, Marit
    Draget, Kurt I.
    Dias, Rita S.
    Stokke, Bjorn T.
    [J]. POLYMERS, 2015, 7 (02): : 161 - 185
  • [23] Advances in paper-based point-of-care diagnostics
    Hu, Jie
    Wang, ShuQi
    Wang, Lin
    Li, Fei
    Pingguan-Murphy, Belinda
    Lu, Tian Jian
    Xu, Feng
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 54 : 585 - 597
  • [24] Electrochemistry and electrocatalysis with heme proteins in chitosan biopolymer films
    Huang, H
    Hu, NF
    Zeng, YH
    Zhou, G
    [J]. ANALYTICAL BIOCHEMISTRY, 2002, 308 (01) : 141 - 151
  • [25] Barrier and surface properties of chitosan-coated greaseproof paper
    Kjellgren, Henrik
    Gallstedt, Mikael
    Engstrom, Gunnar
    Jarnstrom, Larss
    [J]. CARBOHYDRATE POLYMERS, 2006, 65 (04) : 453 - 460
  • [26] Paper-based microfluidic devices for analysis of clinically relevant analytes present in urine and saliva
    Klasner, Scott A.
    Price, Alexander K.
    Hoeman, Kurt W.
    Wilson, Rashaun S.
    Bell, Kayla J.
    Culbertson, Christopher T.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) : 1821 - 1829
  • [27] Koev ST, 2010, LAB CHIP, V10, P3026, DOI [10.1039/c0lc00047g, 10.1039/c01c00047g]
  • [28] Tear glucose dynamics in diabetes mellitus
    Lane, Jennifer D.
    Krumholz, David M.
    Sack, Robert A.
    Morris, Carol
    [J]. CURRENT EYE RESEARCH, 2006, 31 (11) : 895 - 901
  • [29] Portable paper-based device for quantitative colorimetric assays relying on light reflectance principle
    Li, Bowei
    Fu, Longwen
    Zhang, Wei
    Feng, Weiwei
    Chen, Lingxin
    [J]. ELECTROPHORESIS, 2014, 35 (08) : 1152 - 1159
  • [30] Laminated Paper-Based Analytical Devices (LPAD) with Origami-Enabled Chemiluminescence Immunoassay for Cotinine Detection in Mouse Serum
    Liu, Wei
    Cassano, Christopher L.
    Xu, Xin
    Fan, Z. Hugh
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (21) : 10270 - 10276